{"product_id":"kingsman-hbzdv4224-42-millivolt-natural-gas-zero-clearance-direct-vent-fireplaces","title":"Kingsman HBZDV4224 42\" Millivolt Natural Gas Zero Clearance Direct Vent Fireplace","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eKingsman HBZDV4224 42\" Millivolt Natural Gas Zero Clearance Direct Vent Fireplace\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Kingsman HBZDV4224 42\" Zero Clearance Direct Vent Fireplace is designed for new home construction or renovation and can be installed throughout the home. This 42-inch gas-burning fireplace features a dual burner, wall switch, 4\/7\" sloped top flue, tempered glass, and louvered framing. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe fireplace features a fully sealed combustion chamber and is available in natural gas and liquid propane. It provides glowing embers and dancing flames with up to 85% maximum efficiency, creating a warm focal point while helping prevent pollution spillage into the home's indoor air. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe millivolt valve system uses a standing pilot and does not require electricity, allowing operation during a power failure with Hi\/Low heat and flame adjustment. The fireplace can also be configured as a clean face or louvered model to suit different installation styles. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Screen Barrier\u003c\/li\u003e\n\u003cli\u003eFully sealed combustion chamber\u003c\/li\u003e\n\u003cli\u003eIncludes removable safety barrier screen\u003c\/li\u003e\n\u003cli\u003eDual burner with Realistic Flame Pattern\u003c\/li\u003e\n\u003cli\u003eTempered glass front radiates heat to the room\u003c\/li\u003e\n\u003cli\u003eAble to be configured as a clean face or louvered model\u003c\/li\u003e\n\u003cli\u003eMillivolt or IPI valve system allows operation during a power failure with Hi\/low heat and flame adjustment\u003c\/li\u003e\n\u003cli\u003eA flame sensor that constantly monitors the pilot flame and provides 100% gas shut off if pilot is not sensed \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHBZDV4224N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Control\u003c\/td\u003e\n\u003ctd\u003eMillivolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue\u003c\/td\u003e\n\u003ctd\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Max.\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Min.\u003c\/td\u003e\n\u003ctd\u003e14,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFE (p.4.1-02)%\u003c\/td\u003e\n\u003ctd\u003e55.69% \/ 57.81%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e4\/7\" Flex or 4\/6 5\/8\" Hard Pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003eTempered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eHeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Supply Pressure Minimum\u003c\/td\u003e\n\u003ctd\u003e5.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Supply Pressure Normal\u003c\/td\u003e\n\u003ctd\u003e7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Supply Pressure Maximum\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold Pressure High\u003c\/td\u003e\n\u003ctd\u003e3.5 IN. W.C.\/.87 KPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold Pressure Low\u003c\/td\u003e\n\u003ctd\u003e1.6 IN. W.C.\/.40 KPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDimension\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eDimension\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeasurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Width (Louvers)\u003c\/td\u003e\n\u003ctd\u003e42\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Height (Louvers)\u003c\/td\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Depth (Louvers)\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Width (CVCK)\u003c\/td\u003e\n\u003ctd\u003e42\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Height (CVCK)\u003c\/td\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Depth (CVCK)\u003c\/td\u003e\n\u003ctd\u003e19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewing Area Width\u003c\/td\u003e\n\u003ctd\u003e33\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewing Area Height\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHBZDV4224 Gas Fireplace\u003c\/li\u003e\n\u003cli\u003eDual Burner\u003c\/li\u003e\n\u003cli\u003eSIT Valve with Hi\/Lo\u003c\/li\u003e\n\u003cli\u003eWall Switch\u003c\/li\u003e\n\u003cli\u003e4\/7\" Sloped Top Flue\u003c\/li\u003e\n\u003cli\u003eTempered Glass\u003c\/li\u003e\n\u003cli\u003eSafety Screen \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eNot Included (Sold Separately)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLog Set (Required)\u003c\/li\u003e\n\u003cli\u003eDesigner Clean View Kit (Required)\u003c\/li\u003e\n\u003cli\u003eBlack Grill Kit (Required)\u003c\/li\u003e\n\u003cli\u003eBlack Surround\u003c\/li\u003e\n\u003cli\u003eRefractory Fiber Brick Liner\u003c\/li\u003e\n\u003cli\u003ePorcelain Reflective Panel Liner\u003c\/li\u003e\n\u003cli\u003eFan Kit With Variable Speed \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eView and Download\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/Kingsman-Product-Guide.pdf?v=1730811749\" title=\"Product Brochure\" rel=\"noopener\" target=\"_blank\"\u003eProduct Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Product Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/HBZDV3624-284224-28_Brochure.pdf?v=1732970193\" target=\"_blank\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Product Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/HBZDV4224-HBZDV4228-Manual.pdf?v=1733002100\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Product Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/36HB-Manual.pdf?v=1732970205\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":52703111807263,"sku":"HBZDV4224N","price":2538.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/Kingsman-HBZDV4224-42-Zero-Clearance-Millivolt-Control-Natural-Gas-Direct-Vent-Fireplace.jpg?v=1784894529","url":"https:\/\/theimperialluxe.com\/products\/kingsman-hbzdv4224-42-millivolt-natural-gas-zero-clearance-direct-vent-fireplaces","provider":"The Imperial Luxe","version":"1.0","type":"link"}