{"product_id":"whisperkool-ceiling-mount-4000-220v-high-efficiency-ductless-split-wine-cellar-cooling-systems","title":"WhisperKOOL Ceiling Mount 4000 220V High Efficiency Ductless Split Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"114\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Ceiling Mount 4000 220V High Efficiency Ductless Split Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"144\" data-end=\"586\"\u003eThe WhisperKOOL Ceiling Mount 4000 220V High Efficiency Ductless Split System is engineered to deliver effective and dependable cooling for wine cellars up to approximately \u003cstrong data-start=\"317\" data-end=\"337\"\u003e1,000 cubic feet\u003c\/strong\u003e when properly insulated and sealed with a vapor barrier. Featuring a ceiling‑mounted evaporator and a remote condenser, this ductless split design keeps the cellar environment quiet and unobtrusive while providing consistent cooling performance. \u003c\/p\u003e\n\u003cp data-start=\"588\" data-end=\"932\"\u003eThis high‑efficiency 220V system boosts energy performance and reduces operating noise compared with standard voltage models, making it an excellent choice for residential or light commercial wine rooms where comfort and discretion matter. The evaporator is mounted flush in the ceiling to optimize usable wall space for racking and storage. \u003c\/p\u003e\n\u003cp data-start=\"934\" data-end=\"1242\"\u003eTemperature control is precise and user‑friendly with the included \u003cstrong data-start=\"1001\" data-end=\"1030\"\u003eKDT digital touch display\u003c\/strong\u003e, which can be mounted up to 50 feet away for convenient monitoring and adjustment. An optional liquid‑temperature bottle probe is available to measure the actual wine temperature for improved cellar accuracy. \u003c\/p\u003e\n\u003cp data-start=\"1244\" data-end=\"1579\"\u003eInstallation is designed to be flexible for custom cellar layouts, with remote condenser placement up to 100 feet away and professional HVAC‑R installation recommended to ensure optimal performance. The WhisperKOOL Ceiling Mount 4000 combines efficient operation with quiet performance to help protect and preserve wine collections. \u003c\/p\u003e\n\u003cp data-start=\"574\" data-end=\"616\"\u003eIt is best suited for homeowners who want:\u003c\/p\u003e\n\u003cul data-start=\"618\" data-end=\"798\"\u003e\n\u003cli data-start=\"618\" data-end=\"658\"\u003eA \u003cstrong data-start=\"622\" data-end=\"658\"\u003eflush ceiling-mounted evaporator\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"659\" data-end=\"712\"\u003eA \u003cstrong data-start=\"663\" data-end=\"683\"\u003eremote condenser\u003c\/strong\u003e (split system configuration)\u003c\/li\u003e\n\u003cli data-start=\"713\" data-end=\"748\"\u003eQuiet operation inside the cellar\u003c\/li\u003e\n\u003cli data-start=\"749\" data-end=\"798\"\u003eClean wall space without through-wall equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"800\" data-end=\"910\"\u003eProper insulation, vapor barrier installation, and a heat load calculation are required to ensure performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eNOTE:\u003c\/span\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"color: #000000;\"\u003eA qualified HVAC-R technician is required for the installation of your WhisperKOOL Ceiling Mount 4000 220V. Failure to adhere to this requirement will void the warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"917\" data-end=\"950\"\u003e\u003cstrong\u003eWho This System Is Designed For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"952\" data-end=\"995\"\u003eThe Ceiling Mount 4000 is appropriate when:\u003c\/p\u003e\n\u003cul data-start=\"997\" data-end=\"1341\"\u003e\n\u003cli data-start=\"997\" data-end=\"1046\"\u003eThe cellar does not exceed \u003cstrong data-start=\"1026\" data-end=\"1046\"\u003e1,000 cubic feet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1047\" data-end=\"1095\"\u003eWalls are insulated (recommended minimum R-19)\u003c\/li\u003e\n\u003cli data-start=\"1096\" data-end=\"1145\"\u003eCeiling is insulated (recommended minimum R-30)\u003c\/li\u003e\n\u003cli data-start=\"1146\" data-end=\"1187\"\u003eA continuous vapor barrier is installed\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1240\"\u003eThe condenser intake air does not exceed \u003cstrong data-start=\"1231\" data-end=\"1240\"\u003e120°F\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1241\" data-end=\"1280\"\u003eA dedicated 220V circuit is available\u003c\/li\u003e\n\u003cli data-start=\"1281\" data-end=\"1341\"\u003eInstallation is performed by a qualified HVAC-R technician\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1343\" data-end=\"1451\"\u003eWhen installed correctly, this system can maintain a \u003cstrong data-start=\"1396\" data-end=\"1423\"\u003e55°F cellar temperature\u003c\/strong\u003e for long-term wine storage.\u003c\/p\u003e\n\u003ch3 data-start=\"1458\" data-end=\"1504\"\u003e\u003cstrong\u003eWhen This System May Not Be the Right Choice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1506\" data-end=\"1562\"\u003eYou may require a larger or different cooling system if:\u003c\/p\u003e\n\u003cul data-start=\"1564\" data-end=\"1869\"\u003e\n\u003cli data-start=\"1564\" data-end=\"1601\"\u003eThe cellar exceeds 1,000 cubic feet\u003c\/li\u003e\n\u003cli data-start=\"1602\" data-end=\"1649\"\u003eThe space includes large glass walls or doors\u003c\/li\u003e\n\u003cli data-start=\"1650\" data-end=\"1694\"\u003eInsulation is insufficient or inconsistent\u003c\/li\u003e\n\u003cli data-start=\"1695\" data-end=\"1723\"\u003eA vapor barrier is missing\u003c\/li\u003e\n\u003cli data-start=\"1724\" data-end=\"1771\"\u003eThe environment is commercial or high traffic\u003c\/li\u003e\n\u003cli data-start=\"1772\" data-end=\"1817\"\u003eThe condenser space regularly exceeds 120°F\u003c\/li\u003e\n\u003cli data-start=\"1818\" data-end=\"1869\"\u003eHeat load calculations indicate higher BTU demand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1871\" data-end=\"1949\"\u003eIn these cases, the Ceiling Mount 8000 or Twin models may be more appropriate.\u003c\/p\u003e\n\u003ch3 data-start=\"1956\" data-end=\"1988\"\u003e\u003cstrong\u003eCooling Performance \u0026amp; Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1990\" data-end=\"2068\"\u003eCooling output varies depending on condenser intake temperature and fan speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2070\" data-end=\"2101\"\u003e\u003cstrong\u003eAt 60°F Condenser Air Intake\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2102\" data-end=\"2184\"\u003e\n\u003cli data-start=\"2102\" data-end=\"2152\"\u003e\n\u003cstrong data-start=\"2104\" data-end=\"2115\"\u003eMedium:\u003c\/strong\u003e 4,871 \/ 5,430 BTU\/h (Sensible\/Total)\u003c\/li\u003e\n\u003cli data-start=\"2153\" data-end=\"2184\"\u003e\n\u003cstrong data-start=\"2155\" data-end=\"2164\"\u003eHigh:\u003c\/strong\u003e 5,324 \/ 6,087 BTU\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2186\" data-end=\"2217\"\u003e\u003cstrong\u003eAt 75°F Condenser Air Intake\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2218\" data-end=\"2283\"\u003e\n\u003cli data-start=\"2218\" data-end=\"2251\"\u003e\n\u003cstrong data-start=\"2220\" data-end=\"2231\"\u003eMedium:\u003c\/strong\u003e 4,752 \/ 5,291 BTU\/h\u003c\/li\u003e\n\u003cli data-start=\"2252\" data-end=\"2283\"\u003e\n\u003cstrong data-start=\"2254\" data-end=\"2263\"\u003eHigh:\u003c\/strong\u003e 5,198 \/ 5,914 BTU\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2285\" data-end=\"2316\"\u003e\u003cstrong\u003eAt 85°F Condenser Air Intake\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2317\" data-end=\"2382\"\u003e\n\u003cli data-start=\"2317\" data-end=\"2350\"\u003e\n\u003cstrong data-start=\"2319\" data-end=\"2330\"\u003eMedium:\u003c\/strong\u003e 4,631 \/ 5,147 BTU\/h\u003c\/li\u003e\n\u003cli data-start=\"2351\" data-end=\"2382\"\u003e\n\u003cstrong data-start=\"2353\" data-end=\"2362\"\u003eHigh:\u003c\/strong\u003e 4,945 \/ 5,351 BTU\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2384\" data-end=\"2536\"\u003ePerformance decreases as condenser air temperature rises. Maintaining a controlled mechanical room environment improves system efficiency and longevity.\u003c\/p\u003e\n\u003ch3 data-start=\"2543\" data-end=\"2566\"\u003e\u003cstrong\u003eInstallation Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2568\" data-end=\"2597\"\u003e\u003cstrong\u003eSplit System Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2599\" data-end=\"2807\"\u003e\n\u003cli data-start=\"2599\" data-end=\"2667\"\u003eEvaporator installs flush between ceiling joists inside the cellar\u003c\/li\u003e\n\u003cli data-start=\"2668\" data-end=\"2724\"\u003eCondenser installs remotely (up to 100 line feet away)\u003c\/li\u003e\n\u003cli data-start=\"2725\" data-end=\"2769\"\u003eReduces mechanical noise inside the cellar\u003c\/li\u003e\n\u003cli data-start=\"2770\" data-end=\"2807\"\u003ePreserves wall space and aesthetics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003e\u003cstrong\u003eDrain Line\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2823\" data-end=\"2868\"\u003e\n\u003cli data-start=\"2823\" data-end=\"2868\"\u003e1\/2\" ID clear plastic tubing (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2870\" data-end=\"2907\"\u003e\u003cstrong\u003eProfessional Installation Required\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2908\" data-end=\"3025\"\u003eA qualified HVAC-R technician must perform installation. Failure to use professional installation voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3032\" data-end=\"3066\"\u003e\u003cstrong\u003eTemperature Control \u0026amp; Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3068\" data-end=\"3094\"\u003e\u003cstrong\u003eBottle Probe Technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3096\" data-end=\"3200\"\u003eThe liquid-temperature bottle probe measures actual wine temperature instead of ambient air temperature.\u003c\/p\u003e\n\u003cp data-start=\"3202\" data-end=\"3216\"\u003eThis provides:\u003c\/p\u003e\n\u003cul data-start=\"3217\" data-end=\"3316\"\u003e\n\u003cli data-start=\"3217\" data-end=\"3249\"\u003eImproved temperature stability\u003c\/li\u003e\n\u003cli data-start=\"3250\" data-end=\"3273\"\u003eReduced short cycling\u003c\/li\u003e\n\u003cli data-start=\"3274\" data-end=\"3316\"\u003eMore accurate long-term aging conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3323\" data-end=\"3350\"\u003e\u003cstrong\u003eAdvanced Digital Display\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3352\" data-end=\"3454\"\u003e\n\u003cli data-start=\"3352\" data-end=\"3375\"\u003eDigital touch control\u003c\/li\u003e\n\u003cli data-start=\"3376\" data-end=\"3404\"\u003e50 ft. communication cable\u003c\/li\u003e\n\u003cli data-start=\"3405\" data-end=\"3431\"\u003eSystem protection alarms\u003c\/li\u003e\n\u003cli data-start=\"3432\" data-end=\"3454\"\u003eReal-time monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3461\" data-end=\"3502\"\u003e\u003cstrong\u003eOptional 24V Thermostat Conversion Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3504\" data-end=\"3587\"\u003eAn optional 24V conversion kit allows connection to a customer-supplied thermostat.\u003c\/p\u003e\n\u003cp data-start=\"3589\" data-end=\"3614\"\u003eImportant considerations:\u003c\/p\u003e\n\u003cul data-start=\"3616\" data-end=\"3816\"\u003e\n\u003cli data-start=\"3616\" data-end=\"3700\"\u003eThe standard WhisperKOOL control and bottle probe are removed when using 24V mode.\u003c\/li\u003e\n\u003cli data-start=\"3701\" data-end=\"3750\"\u003eWhisperKOOL does not provide smart thermostats.\u003c\/li\u003e\n\u003cli data-start=\"3751\" data-end=\"3816\"\u003eTechnical support does not cover third-party thermostat issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3818\" data-end=\"3908\"\u003eThis option is intended for users integrating cellar cooling into home automation systems.\u003c\/p\u003e\n\u003ch2 data-start=\"3915\" data-end=\"3941\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3943\" data-end=\"3965\"\u003e\u003cstrong\u003eMaximum Cellar Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3966\" data-end=\"4069\"\u003e\n\u003cli data-start=\"3966\" data-end=\"3988\"\u003eUp to 1,000 cu. ft.*\u003c\/li\u003e\n\u003cli data-start=\"3989\" data-end=\"4033\"\u003eRequires full insulation and vapor barrier\u003c\/li\u003e\n\u003cli data-start=\"4034\" data-end=\"4069\"\u003eHeat load calculation recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4071\" data-end=\"4132\"\u003e*Performance estimates assume a sealed, insulated enclosure.\u003c\/p\u003e\n\u003ch3 data-start=\"4139\" data-end=\"4165\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4166\" data-end=\"4262\"\u003e\n\u003cli data-start=\"4166\" data-end=\"4208\"\u003e220V (15 amp dedicated circuit required)\u003c\/li\u003e\n\u003cli data-start=\"4209\" data-end=\"4228\"\u003eRunning Amps: 1.4\u003c\/li\u003e\n\u003cli data-start=\"4229\" data-end=\"4240\"\u003eLRA: 10.7\u003c\/li\u003e\n\u003cli data-start=\"4241\" data-end=\"4251\"\u003eRLA: 2.7\u003c\/li\u003e\n\u003cli data-start=\"4252\" data-end=\"4262\"\u003eFLA: 3.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4269\" data-end=\"4284\"\u003e\u003cstrong\u003eNoise Levels\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4285\" data-end=\"4339\"\u003e\n\u003cli data-start=\"4285\" data-end=\"4302\"\u003e48 dBA (Medium)\u003c\/li\u003e\n\u003cli data-start=\"4303\" data-end=\"4318\"\u003e53 dBA (High)\u003c\/li\u003e\n\u003cli data-start=\"4319\" data-end=\"4339\"\u003e43 dBA (Condenser)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4346\" data-end=\"4368\"\u003e\u003cstrong\u003eDimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4370\" data-end=\"4384\"\u003e\u003cstrong\u003eEvaporator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4385\" data-end=\"4425\"\u003e\n\u003cli data-start=\"4385\" data-end=\"4416\"\u003e35.75” L x 14.5” W x 12.75” H\u003c\/li\u003e\n\u003cli data-start=\"4417\" data-end=\"4425\"\u003e66 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4427\" data-end=\"4440\"\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4441\" data-end=\"4482\"\u003e\n\u003cli data-start=\"4441\" data-end=\"4473\"\u003e31.18” L x 10.75” W x 21.18” H\u003c\/li\u003e\n\u003cli data-start=\"4474\" data-end=\"4482\"\u003e55 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4489\" data-end=\"4503\"\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4504\" data-end=\"4512\"\u003e\n\u003cli data-start=\"4504\" data-end=\"4512\"\u003eR-134a\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4519\" data-end=\"4539\"\u003e\u003cstrong\u003eTemperature Delta\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4540\" data-end=\"4644\"\u003e\n\u003cli data-start=\"4540\" data-end=\"4586\"\u003eDesigned to maintain 55°F cellar temperature\u003c\/li\u003e\n\u003cli data-start=\"4587\" data-end=\"4644\"\u003eOperates with condenser intake temperatures up to 120°F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4651\" data-end=\"4662\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4663\" data-end=\"4752\"\u003e\n\u003cli data-start=\"4663\" data-end=\"4708\"\u003eTwo-year limited warranty (parts and labor)\u003c\/li\u003e\n\u003cli data-start=\"4709\" data-end=\"4752\"\u003eValid only with professional installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Ceiling Mount 4000 Ductless Split\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Owner_Manual_fe941a2a-f14a-49ab-b11c-091022f2dd18.pdf?v=1646311281\" title=\"Owner Manual  for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\" target=\"_blank\"\u003eOwner Manual for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/H.E._Owner_Manual.pdf?v=1646310971\" title=\"H.E. Owner Manual for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\" target=\"_blank\"\u003eH.E. Owner Manual for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Addendum.pdf?v=1646311024\" title=\"Addendum for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\" target=\"_blank\"\u003eAddendum for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/220V_High-Efficiency_Product_Sheets_b23e7b59-7d78-4aea-94bd-d61592e8065b.pdf?v=1646688714\" title=\"220V High Efficiency Product Sheets for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\" target=\"_blank\"\u003e220V High Efficiency Product Sheets for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/24V_Thermostat_Conversion_Kit.pdf?v=1646311024\" title=\"24V Thermostat Conversion Kit for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\" target=\"_blank\"\u003eNew 24V Thermostat Conversion Kit for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Warranty_Checklist-Split_Systems_H.E.-051021.pdf?v=1646259053\" title=\"High Efficiency 220 Warranty Registration for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\" target=\"_blank\"\u003eHigh Efficiency 220 Warranty Registration for WhisperKOOL Ceiling Mount 4000 Ductless Split System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCeiling Mount 4000 vs 8000 – Which Should You Choose?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eCeiling Mount 4000\u003c\/th\u003e\n\u003cth\u003eCeiling Mount 8000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cellar Size\u003c\/td\u003e\n\u003ctd\u003e1,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e2,000 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Output\u003c\/td\u003e\n\u003ctd\u003eUp to 6,087 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eHigher capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdeal Use\u003c\/td\u003e\n\u003ctd\u003eResidential, moderate heat load\u003c\/td\u003e\n\u003ctd\u003eLarger or higher load cellars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf your cellar approaches 1,000 cubic feet or includes glass or elevated ambient temperatures, sizing up may prevent performance issues.\u003c\/p\u003e\n\u003ch3 data-start=\"6591\" data-end=\"6624\"\u003e\u003cstrong\u003eProfessional Sizing Recommended\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"6626\" data-end=\"6791\"\u003eEvery wine cellar has unique construction variables. Before selecting a cooling system, a heat load calculation should be performed to confirm capacity requirements.\u003c\/p\u003e\n\u003cp data-start=\"6793\" data-end=\"6932\"\u003eIf you are unsure whether the Ceiling Mount 4000 is appropriate for your space, professional consultation is recommended prior to purchase.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299582734623,"sku":"S-WKCM4000-220","price":8295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-ceiling-mount-4000-ductless-split-system-220v-high-efficiency-1187288240.jpg?v=1775520242","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-ceiling-mount-4000-220v-high-efficiency-ductless-split-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}