{"product_id":"whisperkool-ceiling-mount-8000-omega-110v-wine-cellar-cooling-systems","title":"WhisperKOOL Ceiling Mount 8000 OMEGA 110V Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"91\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Ceiling Mount 8000 OMEGA 110V Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"121\" data-end=\"540\"\u003eThe WhisperKOOL Ceiling Mount 8000 OMEGA 110V Wine Cellar Cooling Unit is a powerful and space-efficient solution designed for medium to large wine cellars up to approximately \u003cstrong data-start=\"297\" data-end=\"317\"\u003e1,500 cubic feet\u003c\/strong\u003e when properly insulated and sealed. Its ceiling-mounted configuration allows the unit to be installed flush within the cellar, maximizing wall and floor space while delivering consistent and reliable cooling performance.\u003c\/p\u003e\n\u003cp data-start=\"542\" data-end=\"855\"\u003eOperating on standard 110V power, this system is ideal for residential applications where higher voltage is not available. The ceiling-mounted design efficiently pulls in rising warm air, cools it, and redistributes conditioned air evenly throughout the cellar, helping maintain optimal wine storage conditions.\u003c\/p\u003e\n\u003cp data-start=\"857\" data-end=\"1150\"\u003eEquipped with a digital controller and compatible with a liquid-temperature bottle probe, the system ensures accurate temperature monitoring and control. Its quiet operation and compact design make it suitable for installations where both performance and minimal visual impact are important.\u003c\/p\u003e\n\u003cp data-start=\"1152\" data-end=\"1399\"\u003eBuilt for durability and long-term reliability, the WhisperKOOL Ceiling Mount 8000 OMEGA offers dependable cooling performance, making it an excellent choice for preserving wine collections in custom residential or light commercial environments.\u003c\/p\u003e\n\u003cp data-start=\"945\" data-end=\"995\"\u003e\u003cstrong\u003eIs the Ceiling Mount 8000 Right for Your Cellar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"997\" data-end=\"1013\"\u003e\u003cstrong\u003e✔ Ideal For:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1014\" data-end=\"1296\"\u003e\n\u003cli data-start=\"1014\" data-end=\"1058\"\u003eCellars between \u003cstrong data-start=\"1032\" data-end=\"1058\"\u003e1,500–2,000 cubic feet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1059\" data-end=\"1114\"\u003eFully insulated rooms (minimum R19 walls recommended)\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1150\"\u003eSealed vapor barrier construction\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1185\"\u003eAmbient environments up to 120°F\u003c\/li\u003e\n\u003cli data-start=\"1186\" data-end=\"1238\"\u003eInstallations requiring remote condenser placement\u003c\/li\u003e\n\u003cli data-start=\"1239\" data-end=\"1296\"\u003eProjects where wall space must remain clear for racking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1298\" data-end=\"1324\"\u003e\u003cstrong\u003e✖ Not Recommended For:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1325\" data-end=\"1573\"\u003e\n\u003cli data-start=\"1325\" data-end=\"1370\"\u003eUninsulated basements or passive wine rooms\u003c\/li\u003e\n\u003cli data-start=\"1371\" data-end=\"1418\"\u003eGlass-heavy wine walls without thermal breaks\u003c\/li\u003e\n\u003cli data-start=\"1419\" data-end=\"1466\"\u003eOpen-concept rooms connected to living spaces\u003c\/li\u003e\n\u003cli data-start=\"1467\" data-end=\"1512\"\u003eDIY installation (licensed HVAC\/R required)\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1573\"\u003eSpaces exceeding 2,000 cubic feet without load calculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1575\" data-end=\"1708\"\u003eIf your cellar design includes extensive glass or marginal insulation, consult a cooling load calculation before selecting this unit.\u003c\/p\u003e\n\u003ch3 data-start=\"1715\" data-end=\"1745\"\u003e\u003cstrong\u003eHow the Cooling System Works\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1747\" data-end=\"1785\"\u003eThe system uses a split configuration:\u003c\/p\u003e\n\u003cul data-start=\"1787\" data-end=\"1972\"\u003e\n\u003cli data-start=\"1787\" data-end=\"1891\"\u003e\n\u003cstrong data-start=\"1789\" data-end=\"1819\"\u003eEvaporator (inside cellar)\u003c\/strong\u003e: Pulls warm air from ceiling level and redistributes cooled air evenly.\u003c\/li\u003e\n\u003cli data-start=\"1892\" data-end=\"1972\"\u003e\n\u003cstrong data-start=\"1894\" data-end=\"1925\"\u003eCondenser (remote location)\u003c\/strong\u003e: Exhausts heat outside the cellar environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1974\" data-end=\"2141\"\u003eBy drawing warm air from the ceiling—where heat naturally accumulates—the unit reduces stratification and prevents hot spots, helping maintain stable aging conditions.\u003c\/p\u003e\n\u003ch3 data-end=\"2194\" data-start=\"2148\"\u003e\u003cstrong\u003eWhat the Specifications Mean for Your Cellar\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2231\" data-start=\"2196\"\u003e\u003cstrong\u003eCooling Capacity (BTU Explained)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"2306\" data-start=\"2233\"\u003eCooling performance varies depending on condenser air intake temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2343\" data-start=\"2308\"\u003e\u003cstrong\u003eBTU Output – Ceiling Mount 8000\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Air Intake\u003c\/th\u003e\n\u003cth\u003eMedium Fan (Sensible \/ Total)\u003c\/th\u003e\n\u003cth\u003eHigh Fan (Sensible \/ Total)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003e5305 \/ 6264\u003c\/td\u003e\n\u003ctd\u003e5411 \/ 6411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e5114 \/ 5498\u003c\/td\u003e\n\u003ctd\u003e5217 \/ 5615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e5064 \/ 5358\u003c\/td\u003e\n\u003ctd\u003e5157 \/ 5544\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-end=\"2745\" data-start=\"2632\"\u003e\u003cstrong data-end=\"2652\" data-start=\"2632\"\u003eSensible cooling\u003c\/strong\u003e reduces air temperature.\u003c\/p\u003e\n\u003cp data-end=\"2745\" data-start=\"2632\"\u003e\u003cstrong data-end=\"2697\" data-start=\"2680\"\u003eTotal cooling\u003c\/strong\u003e includes both temperature and moisture removal.\u003c\/p\u003e\n\u003cp data-end=\"2952\" data-start=\"2747\"\u003eWine cellars primarily rely on sensible cooling to maintain 55°F storage conditions. Higher condenser intake temperatures reduce available BTU output, which is why proper condenser ventilation is critical.\u003c\/p\u003e\n\u003ch3 data-end=\"2985\" data-start=\"2959\"\u003e\u003cstrong\u003eFan Speed \u0026amp; Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"3038\" data-start=\"2987\"\u003eThe system offers \u003cstrong data-end=\"3037\" data-start=\"3005\"\u003eMedium and High fan settings\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-end=\"3149\" data-start=\"3040\"\u003e\n\u003cli data-end=\"3087\" data-start=\"3040\"\u003e\n\u003cstrong data-end=\"3052\" data-start=\"3042\"\u003eMedium\u003c\/strong\u003e: Quieter operation, lower airflow.\u003c\/li\u003e\n\u003cli data-end=\"3149\" data-start=\"3088\"\u003e\n\u003cstrong data-end=\"3098\" data-start=\"3090\"\u003eHigh\u003c\/strong\u003e: Increased airflow and slightly higher BTU output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3254\" data-start=\"3151\"\u003eHigher fan speeds may slightly increase evaporator noise but improve air circulation in larger cellars.\u003c\/p\u003e\n\u003ch3 data-end=\"3254\" data-start=\"3151\"\u003e\u003cstrong\u003eNoise Levels (dBA)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMedium\u003c\/th\u003e\n\u003cth\u003eHigh\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator\u003c\/td\u003e\n\u003ctd\u003e48 dBA\u003c\/td\u003e\n\u003ctd\u003e53 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser\u003c\/td\u003e\n\u003ctd\u003e46 dBA\u003c\/td\u003e\n\u003ctd\u003e52 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-end=\"3422\" data-start=\"3410\"\u003eFor context:\u003c\/p\u003e\n\u003cul data-end=\"3498\" data-start=\"3423\"\u003e\n\u003cli data-end=\"3467\" data-start=\"3423\"\u003e40–50 dBA ≈ quiet residential refrigerator\u003c\/li\u003e\n\u003cli data-end=\"3498\" data-start=\"3468\"\u003e60 dBA ≈ normal conversation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3576\" data-start=\"3500\"\u003eThe evaporator is suitable for residential wine rooms when mounted properly.\u003c\/p\u003e\n\u003ch3 data-end=\"3609\" data-start=\"3583\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3783\" data-start=\"3611\"\u003e\n\u003cli data-end=\"3630\" data-start=\"3611\"\u003e\n\u003cstrong data-end=\"3625\" data-start=\"3613\"\u003eVoltage:\u003c\/strong\u003e 120V\u003c\/li\u003e\n\u003cli data-end=\"3688\" data-start=\"3631\"\u003e\n\u003cstrong data-end=\"3648\" data-start=\"3633\"\u003eEvaporator:\u003c\/strong\u003e 120V (5-amp dedicated circuit required)\u003c\/li\u003e\n\u003cli data-end=\"3710\" data-start=\"3689\"\u003e\n\u003cstrong data-end=\"3705\" data-start=\"3691\"\u003eCondenser:\u003c\/strong\u003e 120V\u003c\/li\u003e\n\u003cli data-end=\"3783\" data-start=\"3711\"\u003e\n\u003cstrong data-end=\"3730\" data-start=\"3713\"\u003eRunning Amps:\u003c\/strong\u003e\n\u003cul data-end=\"3783\" data-start=\"3735\"\u003e\n\u003cli data-end=\"3759\" data-start=\"3735\"\u003eEvaporator: 1.4 amps\u003c\/li\u003e\n\u003cli data-end=\"3783\" data-start=\"3762\"\u003eCondenser: 9.5 amps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3864\" data-start=\"3785\"\u003eDedicated circuits are required for proper performance and warranty compliance.\u003c\/p\u003e\n\u003ch3 data-end=\"3895\" data-start=\"3871\"\u003e\u003cstrong\u003eLine Set Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3986\" data-start=\"3897\"\u003e\n\u003cli data-end=\"3919\" data-start=\"3897\"\u003eLiquid line: 1\/4\" OD\u003c\/li\u003e\n\u003cli data-end=\"3986\" data-start=\"3920\"\u003eSuction line:\n\u003cul data-end=\"3986\" data-start=\"3938\"\u003e\n\u003cli data-end=\"3961\" data-start=\"3938\"\u003e1\/2\" OD (under 50 ft)\u003c\/li\u003e\n\u003cli data-end=\"3986\" data-start=\"3964\"\u003e5\/8\" OD (over 50 ft)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4093\" data-start=\"3988\"\u003eLonger line sets require larger suction lines to maintain refrigerant velocity and compressor efficiency.\u003c\/p\u003e\n\u003cp data-end=\"4145\" data-start=\"4095\"\u003eMaximum recommended line set distance: \u003cstrong data-end=\"4144\" data-start=\"4134\"\u003e100 ft\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-end=\"4180\" data-start=\"4152\"\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"4414\" data-start=\"4182\"\u003e\n\u003cli data-end=\"4237\" data-start=\"4182\"\u003eMust be installed by a \u003cstrong data-end=\"4237\" data-start=\"4207\"\u003elicensed HVAC\/R technician\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4282\" data-start=\"4238\"\u003eRequires fully insulated and sealed cellar\u003c\/li\u003e\n\u003cli data-end=\"4307\" data-start=\"4283\"\u003eVapor barrier required\u003c\/li\u003e\n\u003cli data-end=\"4360\" data-start=\"4308\"\u003eCondenser must have proper airflow and ventilation\u003c\/li\u003e\n\u003cli data-end=\"4414\" data-start=\"4361\"\u003eDrain line: 1\/4\" ID tubing (rigid tube recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4474\" data-start=\"4416\"\u003eImproper installation will void the manufacturer warranty.\u003c\/p\u003e\n\u003ch2 data-end=\"4512\" data-start=\"4481\"\u003e\u003cstrong\u003eFull Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"4773\" data-start=\"4514\"\u003e\n\u003cstrong data-end=\"4524\" data-start=\"4514\"\u003eModel:\u003c\/strong\u003e WhisperKool Ceiling Mount 8000 OMEGA 110V\u003c\/li\u003e\n\u003cli data-end=\"4773\" data-start=\"4514\"\u003e\n\u003cstrong data-end=\"4589\" data-start=\"4569\"\u003eCellar Capacity:\u003c\/strong\u003e Up to 2,000 cu. ft.\u003c\/li\u003e\n\u003cli data-end=\"4773\" data-start=\"4514\"\u003e\n\u003cstrong data-end=\"4620\" data-start=\"4612\"\u003eCFM:\u003c\/strong\u003e 321\u003c\/li\u003e\n\u003cli data-end=\"4773\" data-start=\"4514\"\u003e\n\u003cstrong data-end=\"4643\" data-start=\"4627\"\u003eRefrigerant:\u003c\/strong\u003e R-134a\u003c\/li\u003e\n\u003cli data-end=\"4773\" data-start=\"4514\"\u003e\n\u003cstrong data-end=\"4668\" data-start=\"4653\"\u003eHorsepower:\u003c\/strong\u003e 0.5 HP\u003c\/li\u003e\n\u003cli data-end=\"4773\" data-start=\"4514\"\u003e\n\u003cstrong data-end=\"4700\" data-start=\"4678\"\u003eTemperature Delta:\u003c\/strong\u003e Maintains 55°F with condenser air intake up to 120°F\u003c\/li\u003e\n\u003cli data-end=\"4773\" data-start=\"4514\"\u003e\n\u003cstrong data-end=\"4771\" data-start=\"4756\"\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli data-end=\"4816\" data-start=\"4774\"\u003eEvaporator: 35.75”L x 14.5”W x 12.75”H\u003c\/li\u003e\n\u003cli data-end=\"4869\" data-start=\"4817\"\u003eCondenser: 23”L x 15.75”W x 15.3”H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4869\" data-start=\"4817\"\u003e\n\u003cstrong data-end=\"4867\" data-start=\"4856\"\u003eWeight:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli data-end=\"4892\" data-start=\"4870\"\u003eEvaporator: 66 lbs\u003c\/li\u003e\n\u003cli data-end=\"5100\" data-start=\"4893\"\u003eCondenser: 86 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5100\" data-start=\"4893\"\u003e\n\u003cstrong data-end=\"4930\" data-start=\"4915\"\u003eThermostat:\u003c\/strong\u003e Advanced digital display with 50 ft liquid-temperature probe\u003c\/li\u003e\n\u003cli data-end=\"5100\" data-start=\"4893\"\u003e\n\u003cstrong data-end=\"5007\" data-start=\"4994\"\u003eWarranty:\u003c\/strong\u003e Two-year limited warranty with up to one (1) additional year grace period for installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKool Ceiling Mount 8000 OMEGA:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Ceiling Mount Owner's Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Ceiling_Mount_4K_8K_TM_Omega.pdf?v=1738770449\" target=\"_blank\"\u003eOMEGA Ceiling Mount Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Ceiling_Mount_Series_ProductSheet_R1.pdf?v=1738768676\" title=\"OMEGA Ceiling Mount Product Sheet\" target=\"_blank\"\u003eOMEGA Ceiling Mount Product Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Condenser Owner's Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Omega_Condenser_OM_110424_1.pdf?v=1738692728\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Condenser Owner's Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Condenser Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/ProductSheet_R1.pdf?v=1738692821\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Condenser Product Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCeiling Mount 4000 vs 8000 – Which Should You Choose?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e4000\u003c\/th\u003e\n\u003cth\u003e8000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cellar Size\u003c\/td\u003e\n\u003ctd\u003e1,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e2,000 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax BTU (High, 60°F)\u003c\/td\u003e\n\u003ctd\u003e6087\u003c\/td\u003e\n\u003ctd\u003e6411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser Running Amps\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdeal Use\u003c\/td\u003e\n\u003ctd\u003eSmall cellars\u003c\/td\u003e\n\u003ctd\u003eLarge residential or light commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"5418\" data-end=\"5437\"\u003eChoose the 8000 if:\u003c\/p\u003e\n\u003cul data-start=\"5438\" data-end=\"5533\"\u003e\n\u003cli data-start=\"5438\" data-end=\"5477\"\u003eYour cellar exceeds 1,200–1,400 cu ft\u003c\/li\u003e\n\u003cli data-start=\"5478\" data-end=\"5509\"\u003eAmbient conditions are warmer\u003c\/li\u003e\n\u003cli data-start=\"5510\" data-end=\"5533\"\u003eYou need more airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"5540\" data-end=\"5562\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5564\" data-end=\"5628\"\u003e\n\u003cli data-start=\"5564\" data-end=\"5594\"\u003eExterior condenser housing\u003c\/li\u003e\n\u003cli data-start=\"5595\" data-end=\"5628\"\u003e24V thermostat conversion kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"7024\" data-end=\"7055\"\u003e\u003cstrong\u003eImportant Installation Notice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"7057\" data-end=\"7193\"\u003eSplit system cooling units MUST be installed by a qualified licensed HVAC\/R technician. Failure to comply will void the system warranty.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583226143,"sku":"S-WKCM8000-OMEGA","price":8655.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-ceiling-mount-8000-omega-110v-wine-cellar-cooling-unit-1187288011.jpg?v=1775520252","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-ceiling-mount-8000-omega-110v-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}