{"product_id":"whisperkool-extreme-3500ti-self-contained-through-the-wall-wine-cellar-cooling-units","title":"WhisperKOOL Extreme 3500ti Self-Contained Through-the-Wall Wine Cellar Cooling Unit","description":"\u003ch2 data-start=\"0\" data-end=\"104\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Extreme 3500ti Self-Contained Through-the-Wall Wine Cellar Cooling Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"132\" data-end=\"548\"\u003eThe WhisperKOOL Extreme 3500ti Self-Contained Cooling Unit is a powerful and easy-to-install solution designed for wine cellars up to approximately 800 cubic feet. Built as a through-the-wall system, it offers efficient cooling performance while requiring minimal modifications to existing wall structures, making it a practical choice for both new and retrofit installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"550\" data-end=\"950\"\u003eEngineered for reliability and performance, this unit features variable-speed fans that help maintain consistent cellar conditions, ensuring wines are stored at optimal temperatures. Its self-contained design simplifies installation and operation, eliminating the need for a licensed HVAC-R technician while still delivering professional-grade cooling results. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"952\" data-end=\"1321\"\u003eThe Extreme 3500ti is designed to perform even in demanding environments, maintaining stable cellar temperatures despite high ambient conditions. Its advanced digital controller and bottle probe provide accurate monitoring by measuring the actual liquid temperature rather than just the surrounding air, ensuring precise control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1323\" data-end=\"1655\"\u003eWith flexible installation options, including exterior wall mounting and optional ducting configurations, this cooling unit offers adaptability for various cellar designs. Its durable construction and dependable performance make it an ideal solution for preserving wine collections long-term.\u003c\/p\u003e\n\u003cp data-start=\"1187\" data-end=\"1250\"\u003e\u003cstrong\u003eIs the Extreme 3500ti the Right Cooling Unit for Your Cellar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1252\" data-end=\"1387\"\u003eThe Extreme 3500ti is designed for enclosed residential wine rooms where through-the-wall installation is preferred over split systems.\u003c\/p\u003e\n\u003cp data-start=\"1389\" data-end=\"1400\"\u003e\u003cstrong\u003eBest For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1402\" data-end=\"1613\"\u003e\n\u003cli data-start=\"1402\" data-end=\"1454\"\u003eFully enclosed wine rooms up to \u003cstrong data-start=\"1436\" data-end=\"1454\"\u003e800 cubic feet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1455\" data-end=\"1488\"\u003eStandard stud-bay installations\u003c\/li\u003e\n\u003cli data-start=\"1489\" data-end=\"1515\"\u003eResidential applications\u003c\/li\u003e\n\u003cli data-start=\"1516\" data-end=\"1562\"\u003eProjects requiring partial condenser ducting\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1613\"\u003eWarm climates (up to 110°F condenser intake air)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1615\" data-end=\"1631\"\u003e\u003cstrong\u003eNot Ideal For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1633\" data-end=\"1933\"\u003e\n\u003cli data-start=\"1633\" data-end=\"1666\"\u003eCellars larger than 800 cu. ft.\u003c\/li\u003e\n\u003cli data-start=\"1667\" data-end=\"1710\"\u003eOpen floor plans or passive wine displays\u003c\/li\u003e\n\u003cli data-start=\"1711\" data-end=\"1763\"\u003eGlass-dominant designs without upgraded insulation\u003c\/li\u003e\n\u003cli data-start=\"1764\" data-end=\"1804\"\u003eCommercial or hospitality applications\u003c\/li\u003e\n\u003cli data-start=\"1805\" data-end=\"1850\"\u003eMechanical rooms exceeding 110°F intake air\u003c\/li\u003e\n\u003cli data-start=\"1851\" data-end=\"1882\"\u003eRooms without a vapor barrier\u003c\/li\u003e\n\u003cli data-start=\"1883\" data-end=\"1933\"\u003eInstallations without a dedicated 20-amp circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1935\" data-end=\"2091\"\u003eIf your cellar exceeds 800 cu. ft., includes large glass panels, or has elevated ambient heat, a larger unit such as the Extreme 5000ti should be evaluated.\u003c\/p\u003e\n\u003cp data-start=\"2098\" data-end=\"2128\"\u003e\u003cstrong\u003eHow the Extreme 3500ti Works\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2130\" data-end=\"2413\"\u003eThe 3500ti is a \u003cstrong data-start=\"2146\" data-end=\"2179\"\u003eself-contained cooling system\u003c\/strong\u003e, meaning both evaporator and condenser components are housed in one unit. It installs directly through a wall, with the evaporator side cooling the cellar and the condenser side exhausting warm air into an adjacent space or outdoors.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1d7mrtu\" data-start=\"1662\" data-end=\"1673\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1674\" data-end=\"2349\"\u003e\n\u003cli data-section-id=\"1oy5wk4\" data-start=\"1674\" data-end=\"1773\"\u003eDigital controller with advanced system protection alerts \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nmzaak\" data-start=\"1774\" data-end=\"1872\"\u003eBottle probe for accurate liquid temperature measurement \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s317xv\" data-start=\"1873\" data-end=\"1956\"\u003e3-speed fan switch for adjustable airflow \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1drwcny\" data-start=\"1957\" data-end=\"2067\"\u003eExterior grille for protection when installed through exterior walls \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7kkmnj\" data-start=\"2068\" data-end=\"2159\"\u003eVariable-speed fans for optimal cellar conditions \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zgk5bl\" data-start=\"2160\" data-end=\"2258\"\u003eThrough-the-wall installation with minimal modifications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mdhv0h\" data-start=\"2259\" data-end=\"2349\"\u003eNo HVAC-R technician required for installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2415\" data-end=\"2438\"\u003e\u003cstrong\u003e\u003cem\u003eVariable-Speed Fans\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2440\" data-end=\"2593\"\u003eThe variable-speed fans automatically adjust airflow to maintain stable cellar temperatures. This reduces short cycling and helps extend compressor life.\u003c\/p\u003e\n\u003cp data-start=\"2595\" data-end=\"2630\"\u003e\u003cstrong\u003e\u003cem\u003eLiquid-Temperature Bottle Probe\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2632\" data-end=\"2805\"\u003eThe bottle probe measures the liquid temperature of stored wine rather than ambient air. This results in more accurate wine preservation and reduced temperature fluctuation.\u003c\/p\u003e\n\u003cp data-start=\"2807\" data-end=\"2838\"\u003e\u003cem\u003e\u003cstrong\u003eAdvanced Digital Controller\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-start=\"2840\" data-end=\"3028\"\u003eThe front-mounted digital controller monitors system performance and includes built-in protection alerts. It helps prevent freeze-up, overheating, and operational stress on the compressor.\u003c\/p\u003e\n\u003ch2 data-start=\"3035\" data-end=\"3063\"\u003e\u003cstrong\u003ePerformance Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3065\" data-end=\"3084\"\u003e\u003cstrong\u003eCooling Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3086\" data-end=\"3293\"\u003e\n\u003cli data-start=\"3086\" data-end=\"3127\"\u003e\n\u003cstrong data-start=\"3088\" data-end=\"3112\"\u003eMaximum Cellar Size:\u003c\/strong\u003e 800 cu. ft.*\u003c\/li\u003e\n\u003cli data-start=\"3128\" data-end=\"3187\"\u003e\n\u003cstrong data-start=\"3130\" data-end=\"3173\"\u003eBTU Output (85°F condenser air intake):\u003c\/strong\u003e 3,175 BTU\/h\u003c\/li\u003e\n\u003cli data-start=\"3188\" data-end=\"3293\"\u003e\n\u003cstrong data-start=\"3190\" data-end=\"3219\"\u003eTemperature Differential:\u003c\/strong\u003e Maintains 55°F cellar temperature with up to 110°F condenser intake air\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3295\" data-end=\"3373\"\u003e*Capacity assumes a fully insulated, sealed cellar with proper vapor barrier.\u003c\/p\u003e\n\u003ch3 data-start=\"3380\" data-end=\"3406\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3408\" data-end=\"3521\"\u003e\n\u003cli data-start=\"3408\" data-end=\"3429\"\u003e\n\u003cstrong data-start=\"3410\" data-end=\"3422\"\u003eVoltage:\u003c\/strong\u003e 115V\u003c\/li\u003e\n\u003cli data-start=\"3430\" data-end=\"3492\"\u003e\n\u003cstrong data-start=\"3432\" data-end=\"3456\"\u003eCircuit Requirement:\u003c\/strong\u003e 20-amp dedicated circuit required\u003c\/li\u003e\n\u003cli data-start=\"3493\" data-end=\"3521\"\u003e\n\u003cstrong data-start=\"3495\" data-end=\"3512\"\u003eRunning Amps:\u003c\/strong\u003e 9 amps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3523\" data-end=\"3612\"\u003eFailure to provide a dedicated circuit may result in breaker trips or system malfunction.\u003c\/p\u003e\n\u003ch2 data-start=\"3619\" data-end=\"3645\"\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"3647\" data-end=\"3814\"\u003e\n\u003cli data-start=\"3647\" data-end=\"3700\"\u003e\n\u003cstrong data-start=\"3649\" data-end=\"3676\"\u003eDimensions (L × W × H):\u003c\/strong\u003e 28\" × 14.25\" × 15.75\"\u003c\/li\u003e\n\u003cli data-start=\"3701\" data-end=\"3724\"\u003e\n\u003cstrong data-start=\"3703\" data-end=\"3714\"\u003eWeight:\u003c\/strong\u003e 115 lbs\u003c\/li\u003e\n\u003cli data-start=\"3725\" data-end=\"3752\"\u003e\n\u003cstrong data-start=\"3727\" data-end=\"3743\"\u003eRefrigerant:\u003c\/strong\u003e R-134a\u003c\/li\u003e\n\u003cli data-start=\"3753\" data-end=\"3814\"\u003e\n\u003cstrong data-start=\"3755\" data-end=\"3782\"\u003eDrain Line Requirement:\u003c\/strong\u003e 1\/2\" ID tubing (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3821\" data-end=\"3848\"\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3850\" data-end=\"3930\"\u003eProper installation directly impacts system performance and warranty protection.\u003c\/p\u003e\n\u003cp data-start=\"3932\" data-end=\"3955\"\u003e\u003cstrong\u003eInsulation Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3957\" data-end=\"3981\"\u003eMinimum recommendations:\u003c\/p\u003e\n\u003cul data-start=\"3983\" data-end=\"4112\"\u003e\n\u003cli data-start=\"3983\" data-end=\"3998\"\u003eWalls: R-19\u003c\/li\u003e\n\u003cli data-start=\"3999\" data-end=\"4016\"\u003eCeiling: R-30\u003c\/li\u003e\n\u003cli data-start=\"4017\" data-end=\"4053\"\u003eDoor: Fully sealed and insulated\u003c\/li\u003e\n\u003cli data-start=\"4054\" data-end=\"4112\"\u003eVapor barrier: Required on the warm side of the cellar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4114\" data-end=\"4228\"\u003eInsufficient insulation or missing vapor barrier can cause condensation, excessive runtime, and premature failure.\u003c\/p\u003e\n\u003ch3 data-start=\"4235\" data-end=\"4273\"\u003e\u003cstrong\u003eVentilation \u0026amp; Exterior Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4275\" data-end=\"4444\"\u003e\n\u003cli data-start=\"4275\" data-end=\"4320\"\u003eCondenser air intake must not exceed 110°F.\u003c\/li\u003e\n\u003cli data-start=\"4321\" data-end=\"4379\"\u003eExterior wall installations require a protective grille.\u003c\/li\u003e\n\u003cli data-start=\"4380\" data-end=\"4444\"\u003eWarm air exhaust must not recirculate back into the condenser.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4446\" data-end=\"4507\"\u003eImproper venting can cause overheating and compressor damage.\u003c\/p\u003e\n\u003cp data-start=\"4514\" data-end=\"4524\"\u003e\u003cstrong\u003eDucting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4526\" data-end=\"4662\"\u003e\n\u003cli data-start=\"4526\" data-end=\"4586\"\u003eCondensing side can be ducted using approved ducting kits.\u003c\/li\u003e\n\u003cli data-start=\"4587\" data-end=\"4662\"\u003eImproper duct length or diameter can reduce airflow and cooling capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4664\" data-end=\"4746\"\u003eHeat load calculations should always be performed before selecting a cooling unit.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Extreme 3500ti Self-Contained:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Owner's Manual for WhisperKOOL Extreme 3500ti Self-Contained Cooling Unit\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/wine-coolers-empire-whisperkool-extreme-ti-wine-cellar-units-manual.pdf?v=1592358667\" target=\"_blank\"\u003eOwner's Manual for WhisperKOOL Extreme 3500ti Self-Contained Cooling Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Features \u0026amp; Specification Sheet for WhisperKOOL Extreme 3500ti Self-Contained Cooling Unit\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/wine-coolers-empire-whisperkool-extreme-ti-wine-cellar-units-specifications.pdf?v=1592358668\" target=\"_blank\"\u003e\u003cspan\u003eFeatures \u0026amp; Specification Sheet\u003c\/span\u003e for WhisperKOOL Extreme 3500ti Self-Contained Cooling Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Warranty Information for WhisperKOOL Extreme 3500ti Self-Contained Cooling Unit\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/wine-coolers-empire-whisperkool-wine-cellar-units-product-warranty.pdf?v=1592299135\" target=\"_blank\"\u003e\u003cspan\u003eWarranty Information\u003c\/span\u003e for WhisperKOOL Extreme 3500ti Self-Contained Cooling Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eExtreme 3500ti vs 3500tiR\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e3500ti\u003c\/th\u003e\n\u003cth\u003e3500tiR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Location\u003c\/td\u003e\n\u003ctd\u003eFront of unit\u003c\/td\u003e\n\u003ctd\u003eRemote (up to 50 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Required\u003c\/td\u003e\n\u003ctd\u003eEnter cellar to adjust\u003c\/td\u003e\n\u003ctd\u003eAdjust from outside cellar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest For\u003c\/td\u003e\n\u003ctd\u003eStandard residential builds\u003c\/td\u003e\n\u003ctd\u003eHigh-end sealed designs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"5055\" data-end=\"5136\"\u003eChoose the tiR model if remote temperature access is required outside the cellar.\u003c\/p\u003e\n\u003ch3 data-start=\"5143\" data-end=\"5171\"\u003e\u003cstrong\u003eAdvantages and Limitations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5173\" data-end=\"5186\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"5188\" data-end=\"5393\"\u003e\n\u003cli data-start=\"5188\" data-end=\"5233\"\u003eAccurate bottle-probe temperature control\u003c\/li\u003e\n\u003cli data-start=\"5234\" data-end=\"5285\"\u003eOperates in hot climates up to 110°F intake air\u003c\/li\u003e\n\u003cli data-start=\"5286\" data-end=\"5330\"\u003eThrough-the-wall installation simplicity\u003c\/li\u003e\n\u003cli data-start=\"5331\" data-end=\"5365\"\u003eVariable-speed airflow control\u003c\/li\u003e\n\u003cli data-start=\"5366\" data-end=\"5393\"\u003eCondenser side ductable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5395\" data-end=\"5409\"\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"5411\" data-end=\"5622\"\u003e\n\u003cli data-start=\"5411\" data-end=\"5437\"\u003eLimited to 800 cu. ft.\u003c\/li\u003e\n\u003cli data-start=\"5438\" data-end=\"5475\"\u003eRequires dedicated 20-amp circuit\u003c\/li\u003e\n\u003cli data-start=\"5476\" data-end=\"5520\"\u003eNot suitable for open or unsealed spaces\u003c\/li\u003e\n\u003cli data-start=\"5521\" data-end=\"5574\"\u003eExterior grille required for outdoor installation\u003c\/li\u003e\n\u003cli data-start=\"5575\" data-end=\"5622\"\u003e\n\u003cp data-start=\"5577\" data-end=\"5622\"\u003ePerformance dependent on insulation quality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"5629\" data-end=\"5639\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5641\" data-end=\"5733\"\u003e\n\u003cli data-start=\"5641\" data-end=\"5688\"\u003e\u003cstrong data-start=\"5643\" data-end=\"5686\"\u003e2-Year Limited Warranty (Parts \u0026amp; Labor)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"5689\" data-end=\"5733\"\u003e\u003cstrong data-start=\"5691\" data-end=\"5731\"\u003e5-Year Limited Warranty (Compressor)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5735\" data-end=\"5802\"\u003eWarranty applies when installation meets manufacturer requirements.\u003c\/p\u003e\n\u003ch3 data-start=\"7600\" data-end=\"7619\"\u003e\u003cstrong\u003eFinal Positioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"7621\" data-end=\"7929\"\u003eThe WhisperKOOL Extreme 3500ti is a mechanical cooling system designed for properly constructed residential wine cellars up to 800 cubic feet. It is not a decorative appliance or passive display cooler. Performance depends on insulation quality, correct electrical setup, proper venting, and accurate sizing.\u003c\/p\u003e\n\u003cp data-start=\"7931\" data-end=\"8087\"\u003eIf you are uncertain about your cellar’s heat load, insulation level, or venting configuration, a heat load calculation should be performed before purchase.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299584307487,"sku":"U-WK-EX3500TI-115-2","price":5439.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-extreme-3500ti-self-contained-cooling-unit-1187288386.jpg?v=1775520277","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-extreme-3500ti-self-contained-through-the-wall-wine-cellar-cooling-units","provider":"The Imperial Luxe","version":"1.0","type":"link"}