{"product_id":"whisperkool-extreme-8000tir-fully-ducted-wine-cellar-cooling-units","title":"WhisperKOOL Extreme 8000tiR Fully Ducted Wine Cellar Cooling Unit","description":"\u003ch2 data-start=\"0\" data-end=\"86\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Extreme 8000tiR Fully Ducted Wine Cellar Cooling Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"114\" data-end=\"517\"\u003eThe WhisperKOOL Extreme 8000tiR Ducted Cooling Unit is a powerful, self-contained system engineered to provide reliable cooling for wine cellars up to approximately 2,000 cubic feet. Designed for both residential and commercial applications, this unit ensures consistent temperature and humidity levels, helping preserve wine collections under optimal conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"519\" data-end=\"903\"\u003eBuilt with advanced cooling technology, the Extreme 8000tiR features variable-speed fans and a smart thermostat system that adapts to the cellar’s cooling demands. Its fully ducted capability allows the unit to be installed up to 25 feet away from the cellar, offering flexibility while maintaining a quiet and visually unobtrusive environment. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"905\" data-end=\"1241\"\u003eThis system is designed to perform in extreme environments, capable of maintaining stable cellar temperatures between 55°F and 65°F with proper insulation and sealing. Its liquid-temperature bottle probe provides accurate readings by measuring the actual wine temperature rather than ambient air. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1243\" data-end=\"1565\"\u003eWith a KDT Plus remote controller and multiple installation options, the Extreme 8000tiR offers convenience, durability, and efficient performance. It is an ideal solution for collectors seeking a high-capacity cooling unit that combines flexibility, precision, and quiet operation.\u003c\/p\u003e\n\u003cp data-start=\"1134\" data-end=\"1158\"\u003e\u003cstrong\u003eWho This System Is For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1160\" data-end=\"1194\"\u003eThe Extreme tiR is appropriate if:\u003c\/p\u003e\n\u003cul data-start=\"1196\" data-end=\"1577\"\u003e\n\u003cli data-start=\"1196\" data-end=\"1263\"\u003eYour cellar is fully insulated (minimum R-19 walls, R-30 ceiling)\u003c\/li\u003e\n\u003cli data-start=\"1264\" data-end=\"1336\"\u003eA continuous vapor barrier is installed on the warm side of insulation\u003c\/li\u003e\n\u003cli data-start=\"1337\" data-end=\"1429\"\u003eYou need the cooling equipment installed remotely (attic, mechanical room, adjacent space)\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1488\"\u003eMaximum duct run does not exceed 25 equivalent duct feet\u003c\/li\u003e\n\u003cli data-start=\"1489\" data-end=\"1533\"\u003eCondenser intake air does not exceed 110°F\u003c\/li\u003e\n\u003cli data-start=\"1534\" data-end=\"1577\"\u003eA quiet in-cellar environment is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1584\" data-end=\"1616\"\u003e\u003cstrong\u003eWho Should Not Use This System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1618\" data-end=\"1660\"\u003eThe Extreme tiR may not be appropriate if:\u003c\/p\u003e\n\u003cul data-start=\"1662\" data-end=\"1979\"\u003e\n\u003cli data-start=\"1662\" data-end=\"1706\"\u003eThe cellar exceeds the rated cubic footage\u003c\/li\u003e\n\u003cli data-start=\"1707\" data-end=\"1774\"\u003eInsulation or vapor barrier is incomplete or improperly installed\u003c\/li\u003e\n\u003cli data-start=\"1775\" data-end=\"1839\"\u003eSignificant glass exposure increases heat load beyond capacity\u003c\/li\u003e\n\u003cli data-start=\"1840\" data-end=\"1877\"\u003eDuct runs exceed 25 equivalent feet\u003c\/li\u003e\n\u003cli data-start=\"1878\" data-end=\"1922\"\u003eAmbient intake air regularly exceeds 110°F\u003c\/li\u003e\n\u003cli data-start=\"1923\" data-end=\"1979\"\u003eThe installation space cannot provide adequate airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1981\" data-end=\"2054\"\u003eImproper installation is the most common cause of cooling system failure.\u003c\/p\u003e\n\u003cp data-start=\"2061\" data-end=\"2103\"\u003e\u003cstrong\u003eWhat Makes the Extreme tiR Fully Ducted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2105\" data-end=\"2224\"\u003eUnlike through-the-wall systems, the Extreme tiR allows \u003cstrong data-start=\"2161\" data-end=\"2213\"\u003eboth evaporator and condenser sides to be ducted\u003c\/strong\u003e, enabling:\u003c\/p\u003e\n\u003cul data-start=\"2226\" data-end=\"2375\"\u003e\n\u003cli data-start=\"2226\" data-end=\"2275\"\u003eInstallation up to 25 equivalent duct feet away\u003c\/li\u003e\n\u003cli data-start=\"2276\" data-end=\"2320\"\u003eReduced mechanical noise inside the cellar\u003c\/li\u003e\n\u003cli data-start=\"2321\" data-end=\"2347\"\u003eFlexible exhaust routing\u003c\/li\u003e\n\u003cli data-start=\"2348\" data-end=\"2375\"\u003eCleaner cellar aesthetics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2377\" data-end=\"2405\"\u003eUnit plenums ship unpainted.\u003c\/p\u003e\n\u003cp data-start=\"2412\" data-end=\"2445\"\u003e\u003cstrong\u003eCooling Capacity \u0026amp; Model Sizing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2447\" data-end=\"2479\"\u003eThe following capacities assume:\u003c\/p\u003e\n\u003cul data-start=\"2481\" data-end=\"2584\"\u003e\n\u003cli data-start=\"2481\" data-end=\"2500\"\u003eProper insulation\u003c\/li\u003e\n\u003cli data-start=\"2501\" data-end=\"2527\"\u003eContinuous vapor barrier\u003c\/li\u003e\n\u003cli data-start=\"2528\" data-end=\"2547\"\u003eFully sealed door\u003c\/li\u003e\n\u003cli data-start=\"2548\" data-end=\"2584\"\u003eMaximum 110°F condenser intake air\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eRecommended Cellar Size*\u003c\/th\u003e\n\u003cth\u003eBTU\/h @ 85°F Intake\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500tiR\u003c\/td\u003e\n\u003ctd\u003eUp to 800 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e2,688 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000tiR\u003c\/td\u003e\n\u003ctd\u003eUp to 1,250 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e3,794 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8000tiR\u003c\/td\u003e\n\u003ctd\u003eUp to 2,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e5,760 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"2907\" data-end=\"2983\"\u003e*Capacities are approximate and assume proper insulation and vapor sealing.\u003c\/p\u003e\n\u003cp data-start=\"2985\" data-end=\"3130\"\u003eIf your cellar size is near the upper limit, or includes glass walls, warm climate exposure, or concrete construction, sizing up may be required.\u003c\/p\u003e\n\u003ch3 data-start=\"3137\" data-end=\"3164\"\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3166\" data-end=\"3195\"\u003e\u003cstrong\u003eInsulation \u0026amp; Vapor Barrier\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3197\" data-end=\"3219\"\u003eFor rated performance:\u003c\/p\u003e\n\u003cul data-start=\"3221\" data-end=\"3404\"\u003e\n\u003cli data-start=\"3221\" data-end=\"3253\"\u003eMinimum R-19 wall insulation\u003c\/li\u003e\n\u003cli data-start=\"3254\" data-end=\"3289\"\u003eMinimum R-30 ceiling insulation\u003c\/li\u003e\n\u003cli data-start=\"3290\" data-end=\"3347\"\u003eContinuous vapor barrier (minimum 6-mil polyethylene)\u003c\/li\u003e\n\u003cli data-start=\"3348\" data-end=\"3375\"\u003eAll penetrations sealed\u003c\/li\u003e\n\u003cli data-start=\"3376\" data-end=\"3404\"\u003eInsulated, gasketed door\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3406\" data-end=\"3500\"\u003eWithout proper insulation and vapor barrier, condensation and insufficient cooling will occur.\u003c\/p\u003e\n\u003cp data-start=\"3507\" data-end=\"3530\"\u003e\u003cstrong\u003eDucting Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3532\" data-end=\"3754\"\u003e\n\u003cli data-start=\"3532\" data-end=\"3565\"\u003eMaximum 25 equivalent duct feet\u003c\/li\u003e\n\u003cli data-start=\"3566\" data-end=\"3617\"\u003eEquivalent length includes elbows and transitions\u003c\/li\u003e\n\u003cli data-start=\"3618\" data-end=\"3635\"\u003e10\" return duct\u003c\/li\u003e\n\u003cli data-start=\"3636\" data-end=\"3679\"\u003e8\" supply duct (evaporator and condenser)\u003c\/li\u003e\n\u003cli data-start=\"3680\" data-end=\"3754\"\u003eProper airflow must be maintained to prevent static pressure restriction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3756\" data-end=\"3830\"\u003eExceeding duct limits can reduce cooling capacity and cause short cycling.\u003c\/p\u003e\n\u003ch3 data-start=\"3837\" data-end=\"3863\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3865\" data-end=\"3986\"\u003e\n\u003cli data-start=\"3865\" data-end=\"3907\"\u003e115V (20 amp dedicated circuit required)\u003c\/li\u003e\n\u003cli data-start=\"3908\" data-end=\"3947\"\u003e230V option (subject to availability)\u003c\/li\u003e\n\u003cli data-start=\"3948\" data-end=\"3986\"\u003eRunning amps: 9–10 (model dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3993\" data-end=\"4022\"\u003e\u003cstrong\u003eControl \u0026amp; Monitoring System\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4024\" data-end=\"4097\"\u003eThe Extreme tiR includes the Remote Platinum Series Controller featuring:\u003c\/p\u003e\n\u003cul data-start=\"4099\" data-end=\"4299\"\u003e\n\u003cli data-start=\"4099\" data-end=\"4138\"\u003eAdvanced System Protection Technology\u003c\/li\u003e\n\u003cli data-start=\"4139\" data-end=\"4176\"\u003eMultiple internal monitoring probes\u003c\/li\u003e\n\u003cli data-start=\"4177\" data-end=\"4195\"\u003eQuick-Chill mode\u003c\/li\u003e\n\u003cli data-start=\"4196\" data-end=\"4217\"\u003eAnti-Frost function\u003c\/li\u003e\n\u003cli data-start=\"4218\" data-end=\"4261\"\u003eLiquid-temperature measuring bottle probe\u003c\/li\u003e\n\u003cli data-start=\"4262\" data-end=\"4299\"\u003e50 ft. remote digital display cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4301\" data-end=\"4411\"\u003eThe bottle probe measures actual liquid temperature, reducing rapid cycling caused by ambient air fluctuation.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (with duct plenums)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDimensions (L x H x W)\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500tiR\u003c\/td\u003e\n\u003ctd\u003e39.5\" x 22.5\" x 14.25\"\u003c\/td\u003e\n\u003ctd\u003e115 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000tiR\u003c\/td\u003e\n\u003ctd\u003e39.5\" x 26\" x 14.25\"\u003c\/td\u003e\n\u003ctd\u003e150 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8000tiR\u003c\/td\u003e\n\u003ctd\u003e39.5\" x 26\" x 14.25\"\u003c\/td\u003e\n\u003ctd\u003e150 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-start=\"4784\" data-end=\"4812\"\u003e\u003cstrong\u003eAdditional Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4814\" data-end=\"5237\"\u003e\n\u003cli data-start=\"4814\" data-end=\"4837\"\u003eRefrigerant: R-134a\u003c\/li\u003e\n\u003cli data-start=\"4838\" data-end=\"4897\"\u003eDrain Line: 1\/2\" ID clear plastic tubing (not provided)\u003c\/li\u003e\n\u003cli data-start=\"4898\" data-end=\"4935\"\u003eDuct Size: 10\" return \/ 8\" supply\u003c\/li\u003e\n\u003cli data-start=\"4936\" data-end=\"5025\"\u003eTemperature Performance: Maintains 55°F cellar temp with up to 110°F condenser intake\u003c\/li\u003e\n\u003cli data-start=\"5026\" data-end=\"5082\"\u003eInstallation Distance: Up to 25 equivalent duct feet\u003c\/li\u003e\n\u003cli data-start=\"5083\" data-end=\"5133\"\u003eThermostat Options: Standard or 24V compatible\u003c\/li\u003e\n\u003cli data-start=\"5134\" data-end=\"5237\"\u003eOutside Venting: Permitted if outdoor temperature does not exceed 110°F (external grille recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Extreme 8000tiR Ducted\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/wine-coolers-empire-whisperkool-fully-ducted-extreme-tir-wine-cellar-units-manual.pdf?v=1592360938\" target=\"_blank\"\u003eOwner's Manual for WhisperKOOL Extreme 8000tiR Ducted Cooling Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/wine-coolers-empire-whisperkool-fully-ducted-extreme-tir-wine-cellar-units-features-and-specs.pdf?v=1592360936\" target=\"_blank\"\u003eFeatures \u0026amp; Specification Sheet for WhisperKOOL Extreme 8000tiR Ducted Cooling Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/wine-coolers-empire-whisperkool-wine-cellar-units-product-warranty.pdf?v=1592299135\" target=\"_blank\"\u003eWarranty Information for WhisperKOOL Extreme 8000tiR Ducted Cooling Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/wine-coolers-empire-whisperkool-24v-thermostat-conversion-kit-features.pdf?v=1592357678\" target=\"_blank\"\u003e24V Thermostat Conversion Kit for WhisperKOOL Extreme 8000tiR Ducted Cooling Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"5244\" data-end=\"5289\"\u003e\u003cstrong\u003eCommon Causes of Cooling Performance Issues\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"5291\" data-end=\"5485\"\u003e\n\u003cli data-start=\"5291\" data-end=\"5328\"\u003eMissing or incomplete vapor barrier\u003c\/li\u003e\n\u003cli data-start=\"5329\" data-end=\"5354\"\u003eInsufficient insulation\u003c\/li\u003e\n\u003cli data-start=\"5355\" data-end=\"5381\"\u003eOversized glass exposure\u003c\/li\u003e\n\u003cli data-start=\"5382\" data-end=\"5422\"\u003eDuct runs exceeding 25 equivalent feet\u003c\/li\u003e\n\u003cli data-start=\"5423\" data-end=\"5457\"\u003eCondenser intake air above 110°F\u003c\/li\u003e\n\u003cli data-start=\"5458\" data-end=\"5485\"\u003eInadequate return airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5487\" data-end=\"5550\"\u003eCorrect installation is critical for performance and longevity.\u003c\/p\u003e\n\u003ch3 data-start=\"5557\" data-end=\"5567\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5569\" data-end=\"5654\"\u003e\n\u003cli data-start=\"5569\" data-end=\"5612\"\u003eTwo-Year Limited Warranty (Parts \u0026amp; Labor)\u003c\/li\u003e\n\u003cli data-start=\"5613\" data-end=\"5654\"\u003eFive-Year Limited Warranty (Compressor)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299584340255,"sku":"U-WK-EX8000TiRFD-115","price":7905.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-extreme-8000tir-ducted-cooling-unit-1187288398.jpg?v=1775520278","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-extreme-8000tir-fully-ducted-wine-cellar-cooling-units","provider":"The Imperial Luxe","version":"1.0","type":"link"}