{"product_id":"whisperkool-platinum-split-4000-220v-high-efficiency-ductless-wine-cellar-cooling-systems","title":"WhisperKOOL Platinum Split 4000 220V High‑Efficiency Ductless Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"109\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Platinum Split 4000 220V High‑Efficiency Ductless Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"139\" data-end=\"632\"\u003eThe WhisperKOOL Platinum Split 4000 220V High‑Efficiency Ductless Cooling System is engineered to deliver reliable and efficient cooling for wine cellars up to approximately \u003cstrong data-start=\"313\" data-end=\"333\"\u003e1,000 cubic feet\u003c\/strong\u003e that are fully insulated and sealed with a vapor barrier. This ductless split design separates the evaporator and condenser, allowing the condenser to be placed remotely—reducing noise and heat inside the cellar while providing effective temperature control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"634\" data-end=\"1074\"\u003eDesigned for modern cellar environments—including glass wine walls, interior rooms, or installations where quiet operation is important—this high‑efficiency 220V system enhances performance and energy usage compared to standard voltage models. Its flexible installation options allow the condenser to be positioned up to 100 line feet from the evaporator, offering flexibility for custom wine spaces. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1076\" data-end=\"1462\"\u003eInstallation and access have been improved with technician‑friendly features such as bottom‑mounted wiring access and flare fittings. Temperature control is managed via an advanced digital display that can be mounted up to 50 feet away, and an optional liquid‑temperature bottle probe is available to ensure accurate reading of cellar conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1464\" data-end=\"1740\"\u003eThis system is best suited for permanently constructed cellars with professional heat load calculations performed prior to installation, ensuring precise and consistent cooling performance tailored to your cellar’s unique characteristics.\u003c\/p\u003e\n\u003cp data-end=\"634\" data-start=\"545\"\u003e\u003cstrong\u003eFor Fully Sealed Wine Cellars Up to 1,000 Cu. Ft. Requiring Remote Condenser Placement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"904\" data-start=\"636\"\u003eThe WhisperKOOL Platinum Split 4000 220V High-Efficiency Ductless Cooling System is designed for \u003cstrong data-end=\"813\" data-start=\"733\"\u003efully insulated and vapor-barrier-sealed wine cellars up to 1,000 cubic feet\u003c\/strong\u003e that require quiet operation and flexible condenser installation up to 100 line feet away.\u003c\/p\u003e\n\u003cp data-end=\"936\" data-start=\"906\"\u003eThis model is best suited for:\u003c\/p\u003e\n\u003cul data-end=\"1163\" data-start=\"938\"\u003e\n\u003cli data-end=\"984\" data-start=\"938\"\u003eModern glass wine walls (properly insulated)\u003c\/li\u003e\n\u003cli data-end=\"1006\" data-start=\"985\"\u003eInterior wine rooms\u003c\/li\u003e\n\u003cli data-end=\"1064\" data-start=\"1007\"\u003eProjects requiring outdoor or attic condenser placement\u003c\/li\u003e\n\u003cli data-end=\"1119\" data-start=\"1065\"\u003eInstallations where interior noise must be minimized\u003c\/li\u003e\n\u003cli data-end=\"1163\" data-start=\"1120\"\u003eCellars with 220V electrical availability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1308\" data-start=\"1165\"\u003eIf your cellar exceeds 1,000 cu. ft. or has heavy glass exposure without insulation, a larger model or engineered load calculation is required.\u003c\/p\u003e\n\u003ch3 data-end=\"1339\" data-start=\"1315\"\u003e\u003cstrong\u003eWho This System Is For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1380\" data-start=\"1341\"\u003eChoose the Platinum Split 4000 220V if:\u003c\/p\u003e\n\u003cul data-end=\"1737\" data-start=\"1382\"\u003e\n\u003cli data-end=\"1429\" data-start=\"1382\"\u003eYour cellar is \u003cstrong data-end=\"1429\" data-start=\"1399\"\u003efully insulated and sealed\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1487\" data-start=\"1430\"\u003eA proper \u003cstrong data-end=\"1474\" data-start=\"1441\"\u003e6-mil vapor barrier (minimum)\u003c\/strong\u003e is installed\u003c\/li\u003e\n\u003cli data-end=\"1540\" data-start=\"1488\"\u003eThe cellar volume does not exceed 1,000 cubic feet\u003c\/li\u003e\n\u003cli data-end=\"1610\" data-start=\"1541\"\u003eYou want the condenser installed remotely (garage, attic, exterior)\u003c\/li\u003e\n\u003cli data-end=\"1673\" data-start=\"1611\"\u003eYou need quieter operation than self-contained units provide\u003c\/li\u003e\n\u003cli data-end=\"1737\" data-start=\"1674\"\u003eYou have access to a 220V dedicated circuit for the condenser\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1781\" data-start=\"1744\"\u003e\u003cstrong\u003eWhen This System Is NOT Appropriate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1819\" data-start=\"1783\"\u003eThis unit should NOT be selected if:\u003c\/p\u003e\n\u003cul data-end=\"2162\" data-start=\"1821\"\u003e\n\u003cli data-end=\"1857\" data-start=\"1821\"\u003eThe cellar lacks a vapor barrier\u003c\/li\u003e\n\u003cli data-end=\"1961\" data-start=\"1858\"\u003eInsulation does not meet recommended R-values (R-19 walls \/ R-30 ceiling minimum typical guideline)\u003c\/li\u003e\n\u003cli data-end=\"2029\" data-start=\"1962\"\u003eThe space exceeds 1,000 cu. ft. without a heat load calculation\u003c\/li\u003e\n\u003cli data-end=\"2091\" data-start=\"2030\"\u003eThe condenser will operate in ambient air exceeding 120°F\u003c\/li\u003e\n\u003cli data-end=\"2162\" data-start=\"2092\"\u003eInstallation will not be performed by a licensed HVAC-R technician\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2299\" data-start=\"2164\"\u003eImproper installation or environmental conditions can result in condensation issues, insufficient cooling, or voided warranty coverage.\u003c\/p\u003e\n\u003ch3 data-end=\"2341\" data-start=\"2306\"\u003e\u003cstrong\u003eHow the Platinum Split 4000 Works\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2388\" data-start=\"2343\"\u003eThis is a \u003cstrong data-end=\"2378\" data-start=\"2353\"\u003eductless split system\u003c\/strong\u003e, meaning:\u003c\/p\u003e\n\u003cul data-end=\"2641\" data-start=\"2390\"\u003e\n\u003cli data-end=\"2451\" data-start=\"2390\"\u003eThe evaporator unit is installed inside or near the cellar.\u003c\/li\u003e\n\u003cli data-end=\"2522\" data-start=\"2452\"\u003eThe condenser unit is installed remotely (up to 100 line feet away).\u003c\/li\u003e\n\u003cli data-end=\"2567\" data-start=\"2523\"\u003eRefrigerant lines connect both components.\u003c\/li\u003e\n\u003cli data-end=\"2641\" data-start=\"2568\"\u003eHeat is removed from the cellar and rejected at the condenser location.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2753\" data-start=\"2643\"\u003eBecause the condenser is separated from the cellar, interior noise and heat buildup are significantly reduced.\u003c\/p\u003e\n\u003cp data-end=\"2781\" data-start=\"2760\"\u003e\u003cstrong\u003eCooling Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"2884\" data-start=\"2783\"\u003ePerformance values assume a fully insulated and sealed cellar with proper vapor barrier installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"2884\" data-start=\"2783\"\u003e\u003cstrong\u003eBTU Output Based on Condenser Air Intake Temperature\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Intake Temp\u003c\/th\u003e\n\u003cth\u003eSensible BTU\u003c\/th\u003e\n\u003cth\u003eTotal BTU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003e4,463\u003c\/td\u003e\n\u003ctd\u003e5,154\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e3,912\u003c\/td\u003e\n\u003ctd\u003e4,348\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e3,766\u003c\/td\u003e\n\u003ctd\u003e4,096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong data-end=\"3146\" data-start=\"3125\"\u003eWhy this matters: \u003c\/strong\u003eAs condenser intake temperature increases, cooling capacity decreases. Condensers installed in hot attics or enclosed garages must have proper ventilation.\u003c\/p\u003e\n\u003ch2 data-end=\"3337\" data-start=\"3311\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-end=\"3358\" data-start=\"3339\"\u003e\u003cstrong\u003eGeneral Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3567\" data-start=\"3360\"\u003e\n\u003cli data-end=\"3394\" data-start=\"3360\"\u003eCellar Size: Up to 1,000 cu. ft.\u003c\/li\u003e\n\u003cli data-end=\"3430\" data-start=\"3395\"\u003eMaximum Line Set Length: 100 feet\u003c\/li\u003e\n\u003cli data-end=\"3452\" data-start=\"3431\"\u003eRefrigerant: R-134a\u003c\/li\u003e\n\u003cli data-end=\"3493\" data-start=\"3453\"\u003eNoise Level: 42–46 dBA (fan dependent)\u003c\/li\u003e\n\u003cli data-end=\"3567\" data-start=\"3494\"\u003eMaintains 55°F cellar temperature with up to 120°F condenser air intake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3602\" data-start=\"3574\"\u003e\u003cstrong\u003eEvaporator Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3776\" data-start=\"3604\"\u003e\n\u003cli data-end=\"3645\" data-start=\"3604\"\u003eDimensions: 22.1” L × 22.5” W × 15.5” H\u003c\/li\u003e\n\u003cli data-end=\"3661\" data-start=\"3646\"\u003eVoltage: 120V\u003c\/li\u003e\n\u003cli data-end=\"3698\" data-start=\"3662\"\u003eDedicated Circuit Required: 15-amp\u003c\/li\u003e\n\u003cli data-end=\"3718\" data-start=\"3699\"\u003eRunning Amps: 2.2\u003c\/li\u003e\n\u003cli data-end=\"3776\" data-start=\"3719\"\u003eDrain Line: 1\/2\" ID clear plastic tubing (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3833\" data-start=\"3783\"\u003e\u003cstrong\u003eCondenser Specifications (220V High-Efficiency)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3985\" data-start=\"3835\"\u003e\n\u003cli data-end=\"3850\" data-start=\"3835\"\u003eVoltage: 220V\u003c\/li\u003e\n\u003cli data-end=\"3887\" data-start=\"3851\"\u003eDedicated Circuit Required: 15-amp\u003c\/li\u003e\n\u003cli data-end=\"3900\" data-start=\"3888\"\u003eLRA: 10.7A\u003c\/li\u003e\n\u003cli data-end=\"3912\" data-start=\"3901\"\u003eRLA: 2.7A\u003c\/li\u003e\n\u003cli data-end=\"3924\" data-start=\"3913\"\u003eFLA: 3.1A\u003c\/li\u003e\n\u003cli data-end=\"3985\" data-start=\"3925\"\u003eInstallation Distance: Up to 100 line feet from evaporator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Platinum Split 4000 Ductless:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Platinum_Split_4K_8K_HE_OM_012524.pdf?v=1743555013\" target=\"_blank\"\u003eOwner Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/H.E._Owner_Manual_b0f8e5f5-c695-490e-96b1-03fb9133ad35.pdf?v=1646316917\" target=\"_blank\"\u003eH.E. Owner Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/220V_High-Efficiency_Product_Sheets_318a6bee-b230-44b5-bfa2-61fb77486e4c.pdf?v=1646316886\" target=\"_blank\"\u003e220V High-Efficiency Product Sheets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Warranty_Checklist-Split_Systems_H.E.-051021.pdf?v=1646259053\" target=\"_blank\"\u003eHigh Efficiency 220 Warranty Registration\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"4015\" data-start=\"3992\"\u003e\u003cstrong\u003eControls \u0026amp; Monitoring\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-end=\"4156\" data-start=\"4017\"\u003e\n\u003cli data-end=\"4057\" data-start=\"4017\"\u003eAdvanced digital display (50-ft cable)\u003c\/li\u003e\n\u003cli data-end=\"4105\" data-start=\"4058\"\u003eLiquid temperature bottle probe (50-ft cable)\u003c\/li\u003e\n\u003cli data-end=\"4156\" data-start=\"4106\"\u003e24V thermostat compatibility (customer supplied)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4302\" data-start=\"4158\"\u003eNote: WhisperKOOL does not provide smart thermostats. A compatible 24V thermostat must be purchased separately for remote control functionality.\u003c\/p\u003e\n\u003ch3 data-end=\"4331\" data-start=\"4309\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"4360\" data-start=\"4333\"\u003e\n\u003cstrong\u003eUV-C Light Technology\u003c\/strong\u003e\u003cbr\u003eEnhances air quality and system cleanliness.\u003cbr data-end=\"4408\" data-start=\"4405\"\u003e(Not available on Mini models.)\u003c\/li\u003e\n\u003cli data-end=\"4474\" data-start=\"4441\"\u003e\n\u003cstrong\u003eExterior Protective Housing\u003c\/strong\u003e\u003cbr\u003eGalvanized steel housing protects condenser from weather exposure.\u003c\/li\u003e\n\u003cli data-end=\"4571\" data-start=\"4543\"\u003e\n\u003cstrong\u003eCondenser Coil Coating\u003c\/strong\u003e\u003cbr\u003eRecommended for coastal environments to prevent salt air corrosion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"4673\" data-start=\"4646\"\u003eInstallation Requirements\u003c\/h2\u003e\n\u003cul data-end=\"4939\" data-start=\"4675\"\u003e\n\u003cli data-end=\"4712\" data-start=\"4675\"\u003eLicensed HVAC-R technician required\u003c\/li\u003e\n\u003cli data-end=\"4773\" data-start=\"4713\"\u003eDedicated electrical circuits for evaporator and condenser\u003c\/li\u003e\n\u003cli data-end=\"4809\" data-start=\"4774\"\u003eProper vapor barrier installation\u003c\/li\u003e\n\u003cli data-end=\"4845\" data-start=\"4810\"\u003eFully insulated walls and ceiling\u003c\/li\u003e\n\u003cli data-end=\"4878\" data-start=\"4846\"\u003eAdequate condenser ventilation\u003c\/li\u003e\n\u003cli data-end=\"4939\" data-start=\"4879\"\u003eHeat load calculation strongly recommended before purchase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"5073\" data-start=\"4941\"\u003eEach wine cellar has unique thermal conditions. Oversizing or undersizing a system can affect humidity control and system longevity.\u003c\/p\u003e\n\u003ch3 data-end=\"5073\" data-start=\"4941\"\u003e\u003cstrong\u003eComparison Within the Platinum Split Series\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eMax Cellar Size\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMini\u003c\/td\u003e\n\u003ctd\u003e500 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e110V\u003c\/td\u003e\n\u003ctd\u003eSmall interior cellars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003ctd\u003e1,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e110V \/ 220V\u003c\/td\u003e\n\u003ctd\u003eStandard residential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8000\u003c\/td\u003e\n\u003ctd\u003e1,750 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e220V\u003c\/td\u003e\n\u003ctd\u003eLarger residential cellars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwin 9000\u003c\/td\u003e\n\u003ctd\u003e3,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e220V\u003c\/td\u003e\n\u003ctd\u003eLarge or commercial projects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf your cellar exceeds 1,000 cu. ft., consider the Platinum Split 8000 or Twin 9000 models.\u003c\/p\u003e\n\u003ch3 data-end=\"6894\" data-start=\"6872\"\u003e\u003cstrong\u003eFinal Recommendation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"7123\" data-start=\"6896\"\u003eThe WhisperKOOL Platinum Split 4000 220V High-Efficiency Ductless System is best suited for fully insulated, vapor-sealed wine cellars up to 1,000 cubic feet that require remote condenser placement and quiet interior operation.\u003c\/p\u003e\n\u003cp data-end=\"7272\" data-start=\"7125\"\u003eIf you are uncertain whether this model matches your cellar conditions, a professional heat load calculation should be completed prior to purchase.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583684895,"sku":"S-WKPS4000-220-WM","price":7805.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-platinum-split-4000-ductless-cooling-system-220v-high-efficiency-1187288176.jpg?v=1775520263","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-platinum-split-4000-220v-high-efficiency-ductless-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}