{"product_id":"whisperkool-platinum-split-8000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","title":"WhisperKOOL Platinum Split 8000 220V High‑Efficiency Ducted Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"107\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Platinum Split 8000 220V High‑Efficiency Ducted Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"137\" data-end=\"568\"\u003eThe WhisperKOOL Platinum Split 8000 220V High‑Efficiency Ducted Cooling System is engineered to provide dependable and quiet climate control for properly constructed wine cellars up to approximately \u003cstrong data-start=\"336\" data-end=\"356\"\u003e1,750 cubic feet\u003c\/strong\u003e. With its split‑system design, the evaporator and condenser are installed separately—keeping noise and heat outside the cellar while delivering stable cooling performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"570\" data-end=\"970\"\u003eThis high‑efficiency 220V system is ideal for residential or light commercial wine rooms that require \u003cstrong data-start=\"672\" data-end=\"724\"\u003eremote condenser placement (up to 100 line feet)\u003c\/strong\u003e and flexible ducted installation. The system’s ability to maintain consistent temperatures in warm climates makes it well‑suited for custom cellars with well‑sealed insulation and effective vapor barriers. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"972\" data-end=\"1360\"\u003eDesigned for professional installation, the Platinum Split 8000 includes advanced temperature controls—a digital touch display with remote mounting capability and a liquid‑temperature bottle probe—to ensure accurate readings and reliable performance. Its robust construction and flexible system layout help preserve optimal wine storage conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1362\" data-end=\"1586\"\u003eBefore selecting this unit, a proper heat load calculation is recommended to verify that the cellar’s size and insulation match the system’s capacity and ensure energy‑efficient cooling. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"769\" data-end=\"819\"\u003eThis system is designed for projects that require:\u003c\/p\u003e\n\u003cul data-start=\"821\" data-end=\"1012\"\u003e\n\u003cli data-start=\"821\" data-end=\"876\"\u003eRemote condenser placement (up to 100 line feet away)\u003c\/li\u003e\n\u003cli data-start=\"877\" data-end=\"910\"\u003eReduced noise inside the cellar\u003c\/li\u003e\n\u003cli data-start=\"911\" data-end=\"941\"\u003eFlexible ducted installation\u003c\/li\u003e\n\u003cli data-start=\"942\" data-end=\"974\"\u003e220V high-efficiency operation\u003c\/li\u003e\n\u003cli data-start=\"975\" data-end=\"1012\"\u003eStable performance in warm climates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1014\" data-end=\"1100\"\u003eHeat load calculations should always be performed prior to selecting a cooling system.\u003c\/p\u003e\n\u003ch3 data-start=\"1107\" data-end=\"1146\"\u003e\u003cstrong\u003eIs This System Right for Your Cellar?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1148\" data-end=\"1192\"\u003e\u003cstrong\u003eThe Platinum Split 8000 is appropriate when:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1194\" data-end=\"1514\"\u003e✔ The cellar is fully insulated (minimum R-19 walls recommended)\u003cbr data-start=\"1258\" data-end=\"1261\"\u003e✔ A continuous vapor barrier is installed\u003cbr data-start=\"1302\" data-end=\"1305\"\u003e✔ The cellar volume does not exceed 1,750 cu. ft.\u003cbr data-start=\"1354\" data-end=\"1357\"\u003e✔ A 220V dedicated 15-amp circuit is available\u003cbr data-start=\"1403\" data-end=\"1406\"\u003e✔ The condenser can be installed in a ventilated environment\u003cbr data-start=\"1466\" data-end=\"1469\"\u003e✔ Duct routing allows proper airflow design\u003c\/p\u003e\n\u003cp data-start=\"1516\" data-end=\"1556\"\u003e\u003cstrong\u003eThis system may not be appropriate when:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1558\" data-end=\"1777\"\u003e✘ The cellar exceeds 1,750 cu. ft.\u003cbr data-start=\"1592\" data-end=\"1595\"\u003e✘ Large uninsulated glass walls are present\u003cbr data-start=\"1638\" data-end=\"1641\"\u003e✘ Insulation or vapor barrier is incomplete\u003cbr data-start=\"1684\" data-end=\"1687\"\u003e✘ Ambient condenser intake frequently exceeds 120°F\u003cbr data-start=\"1738\" data-end=\"1741\"\u003e✘ No HVAC-R installer is available\u003c\/p\u003e\n\u003cp data-start=\"1779\" data-end=\"1883\"\u003eImproper insulation and missing vapor barriers are the most common causes of cooling performance issues.\u003c\/p\u003e\n\u003ch3 data-start=\"1890\" data-end=\"1912\"\u003e\u003cstrong\u003eSystem Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1914\" data-end=\"1958\"\u003eThis is a split ducted system consisting of:\u003c\/p\u003e\n\u003cul data-start=\"1960\" data-end=\"2085\"\u003e\n\u003cli data-start=\"1960\" data-end=\"2017\"\u003e\n\u003cstrong data-start=\"1962\" data-end=\"1981\"\u003eEvaporator Unit\u003c\/strong\u003e installed inside or near the cellar\u003c\/li\u003e\n\u003cli data-start=\"2018\" data-end=\"2085\"\u003e\n\u003cstrong data-start=\"2020\" data-end=\"2039\"\u003eCondensing Unit\u003c\/strong\u003e installed remotely (up to 100 line feet away)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2087\" data-end=\"2215\"\u003eThe ducted configuration allows the cooling equipment to remain discreet and reduces direct sound exposure inside the wine room.\u003c\/p\u003e\n\u003cp data-start=\"2222\" data-end=\"2243\"\u003e\u003cstrong\u003eCooling Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2245\" data-end=\"2325\"\u003eCooling capacity varies based on condenser air intake temperature and fan speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1779\" data-end=\"1883\"\u003e\u003cstrong\u003e8000 Model Cooling Output (Sensible \/ Total BTU)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Air Intake\u003c\/th\u003e\n\u003cth\u003eFan Speed\u003c\/th\u003e\n\u003cth\u003eSensible BTU\u003c\/th\u003e\n\u003cth\u003eTotal BTU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd\u003e4,565\u003c\/td\u003e\n\u003ctd\u003e5,273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd\u003e4,177\u003c\/td\u003e\n\u003ctd\u003e4,561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd\u003e3,957\u003c\/td\u003e\n\u003ctd\u003e4,315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-start=\"2613\" data-end=\"2634\"\u003e\u003cstrong\u003ePerformance Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2636\" data-end=\"2866\"\u003e\n\u003cli data-start=\"2636\" data-end=\"2702\"\u003eHigher condenser air temperatures reduce total cooling capacity.\u003c\/li\u003e\n\u003cli data-start=\"2703\" data-end=\"2761\"\u003eProper condenser ventilation improves system efficiency.\u003c\/li\u003e\n\u003cli data-start=\"2762\" data-end=\"2815\"\u003eSensible BTU represents temperature reduction only.\u003c\/li\u003e\n\u003cli data-start=\"2816\" data-end=\"2866\"\u003eTotal BTU includes humidity management capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2868\" data-end=\"2989\"\u003eWine storage requires both temperature stability and controlled humidity to preserve cork integrity and aging conditions.\u003c\/p\u003e\n\u003ch3 data-start=\"2996\" data-end=\"3018\"\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3020\" data-end=\"3144\"\u003eThe Platinum Split 8000 can maintain a 55°F cellar temperature with condenser air intake temperatures up to 120°F, provided:\u003c\/p\u003e\n\u003cul data-start=\"3146\" data-end=\"3276\"\u003e\n\u003cli data-start=\"3146\" data-end=\"3179\"\u003eThe cellar is fully insulated\u003c\/li\u003e\n\u003cli data-start=\"3180\" data-end=\"3223\"\u003eA continuous vapor barrier is installed\u003c\/li\u003e\n\u003cli data-start=\"3224\" data-end=\"3276\"\u003eHeat load does not exceed system design capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3278\" data-end=\"3381\"\u003eExtreme heat exposure, glass-heavy construction, or under-insulated spaces may require a larger system.\u003c\/p\u003e\n\u003cp data-start=\"3388\" data-end=\"3402\"\u003e\u003cstrong\u003eSound Levels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"3404\" data-end=\"3463\"\u003eEvaporator noise level: \u003cstrong data-start=\"3428\" data-end=\"3441\"\u003e56–62 dBA\u003c\/strong\u003e (varies by fan speed)\u003c\/li\u003e\n\u003cli data-start=\"3465\" data-end=\"3629\"\u003eDucted configuration significantly reduces audible presence inside the cellar compared to self-contained systems. Actual sound levels depend on installation design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3636\" data-end=\"3661\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3663\" data-end=\"3759\"\u003e\n\u003cli data-start=\"3663\" data-end=\"3682\"\u003eVoltage: \u003cstrong data-start=\"3674\" data-end=\"3682\"\u003e220V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3683\" data-end=\"3723\"\u003eDedicated circuit: \u003cstrong data-start=\"3704\" data-end=\"3723\"\u003e15-amp required\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3724\" data-end=\"3735\"\u003eLRA: 13.2\u003c\/li\u003e\n\u003cli data-start=\"3736\" data-end=\"3747\"\u003eRLA: 3.19\u003c\/li\u003e\n\u003cli data-start=\"3748\" data-end=\"3759\"\u003eFLA: 3.66\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3761\" data-end=\"3863\"\u003eInstallation must be performed by a qualified HVAC-R technician. Improper installation voids warranty.\u003c\/p\u003e\n\u003ch2 data-start=\"3870\" data-end=\"3909\"\u003e\u003cstrong\u003eRefrigerant \u0026amp; Line Set Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"3911\" data-end=\"4071\"\u003e\n\u003cli data-start=\"3911\" data-end=\"3936\"\u003eRefrigerant: \u003cstrong data-start=\"3926\" data-end=\"3936\"\u003eR-134a\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3937\" data-end=\"3959\"\u003eLiquid line: 1\/4\" OD\u003c\/li\u003e\n\u003cli data-start=\"3960\" data-end=\"4040\"\u003eSuction line:\n\u003cul data-start=\"3978\" data-end=\"4040\"\u003e\n\u003cli data-start=\"3978\" data-end=\"4006\"\u003e1\/2\" OD (less than 50 ft.)\u003c\/li\u003e\n\u003cli data-start=\"4009\" data-end=\"4040\"\u003e5\/8\" OD (greater than 50 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4041\" data-end=\"4071\"\u003eMaximum line length: 100 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4073\" data-end=\"4153\"\u003eCorrect line sizing is critical to maintaining performance and system longevity.\u003c\/p\u003e\n\u003ch2 data-start=\"4160\" data-end=\"4187\"\u003e\u003cstrong\u003eEvaporator Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4189\" data-end=\"4409\"\u003e\n\u003cli data-start=\"4189\" data-end=\"4232\"\u003eDimensions: 16.1\" L x 20.5\" W x 15.5\" H\u003c\/li\u003e\n\u003cli data-start=\"4233\" data-end=\"4251\"\u003eWeight: 54 lbs\u003c\/li\u003e\n\u003cli data-start=\"4252\" data-end=\"4273\"\u003eRunning Amps: 2.2\u003c\/li\u003e\n\u003cli data-start=\"4274\" data-end=\"4333\"\u003eDrain Line: 1\/2\" ID clear plastic tubing (not included)\u003c\/li\u003e\n\u003cli data-start=\"4334\" data-end=\"4409\"\u003eInstallation: Installed inside the cellar or ducted from adjacent space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4416\" data-end=\"4461\"\u003e\u003cstrong\u003eCondensing Unit Specifications (8000 Model)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4463\" data-end=\"4618\"\u003e\n\u003cli data-start=\"4463\" data-end=\"4485\"\u003eHorsepower: 0.7 HP\u003c\/li\u003e\n\u003cli data-start=\"4486\" data-end=\"4503\"\u003eVoltage: 220V\u003c\/li\u003e\n\u003cli data-start=\"4504\" data-end=\"4522\"\u003eWeight: 56 lbs\u003c\/li\u003e\n\u003cli data-start=\"4523\" data-end=\"4536\"\u003eLRA: 13.2\u003c\/li\u003e\n\u003cli data-start=\"4537\" data-end=\"4550\"\u003eRLA: 3.19\u003c\/li\u003e\n\u003cli data-start=\"4551\" data-end=\"4564\"\u003eFLA: 3.66\u003c\/li\u003e\n\u003cli data-start=\"4565\" data-end=\"4618\"\u003eInstallation: Up to 100 line feet from evaporator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4620\" data-end=\"4681\"\u003eCondenser must be installed in a well-ventilated environment.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Platinum Split 8000 Ducted:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Owner Manual for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Owner_Manual_bf504749-64bf-4012-a24a-c0c28884f0de.pdf?v=1646322715\" target=\"_blank\"\u003e Owner Manual for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"H.E. Owner Manual for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/H.E._Owner_Manual_7cc4e909-9f52-4958-ac48-027d536b4472.pdf?v=1646322696\" target=\"_blank\"\u003eH.E. Owner Manual for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"220V High Efficiency product Sheets for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/220V_High-Efficiency_Product_Sheets_125fad33-b144-4f34-aeb9-1820d073c1bb.pdf?v=1646322286\" target=\"_blank\"\u003e220V High Efficiency Product Sheets for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"24V Thermostat Conversion Kit for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/24V_Thermostat_Conversion_Kit.pdf?v=1646311024\" target=\"_blank\"\u003e24V Thermostat Conversion Kit for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Warranty_Checklist-Split_Systems_H.E.-051021.pdf?v=1646259053\" title=\"High Efficiency 220 Warranty Registration for WhisperKOOL Platinum Split 4000 Ducted Cooling System 220V High Efficiency\" target=\"_blank\"\u003eHigh Efficiency 220 Warranty Registration for WhisperKOOL Platinum Split 8000 Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4688\" data-end=\"4704\"\u003e\u003cstrong\u003eControl System\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4706\" data-end=\"4726\"\u003eThe system includes:\u003c\/p\u003e\n\u003cul data-start=\"4728\" data-end=\"4876\"\u003e\n\u003cli data-start=\"4728\" data-end=\"4771\"\u003eAdvanced digital display with 50 ft cable\u003c\/li\u003e\n\u003cli data-start=\"4772\" data-end=\"4815\"\u003eLiquid-temperature measuring bottle probe\u003c\/li\u003e\n\u003cli data-start=\"4816\" data-end=\"4839\"\u003eTwo-speed fan control\u003c\/li\u003e\n\u003cli data-start=\"4840\" data-end=\"4876\"\u003eOptional 24V thermostat conversion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOptional 24V Thermostat Conversion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4917\" data-end=\"4965\"\u003eAllows integration with third-party thermostats.\u003c\/p\u003e\n\u003cp data-start=\"4967\" data-end=\"4977\"\u003eImportant:\u003c\/p\u003e\n\u003cul data-start=\"4979\" data-end=\"5188\"\u003e\n\u003cli data-start=\"4979\" data-end=\"5027\"\u003eWhisperKOOL does not supply smart thermostats.\u003c\/li\u003e\n\u003cli data-start=\"5028\" data-end=\"5109\"\u003eThe standard bottle probe and controller are removed when using 24V conversion.\u003c\/li\u003e\n\u003cli data-start=\"5110\" data-end=\"5188\"\u003eWhisperKOOL does not provide support for third-party thermostat programming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"5195\" data-end=\"5222\"\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5224\" data-end=\"5421\"\u003e\n\u003cli data-start=\"5224\" data-end=\"5261\"\u003eHVAC-R certified installer required\u003c\/li\u003e\n\u003cli data-start=\"5262\" data-end=\"5308\"\u003eProper insulation and vapor barrier required\u003c\/li\u003e\n\u003cli data-start=\"5309\" data-end=\"5353\"\u003eDedicated 220V electrical circuit required\u003c\/li\u003e\n\u003cli data-start=\"5354\" data-end=\"5390\"\u003eDrain line must be properly routed\u003c\/li\u003e\n\u003cli data-start=\"5391\" data-end=\"5421\"\u003eCondenser must be ventilated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5423\" data-end=\"5513\"\u003eImproper construction is the most common reason a cooling unit fails to reach temperature.\u003c\/p\u003e\n\u003ch3 data-start=\"5652\" data-end=\"5675\"\u003e\u003cstrong\u003eOptional Enhancements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"5677\" data-end=\"5701\"\u003e\n\u003cstrong\u003eUV-C Light Technology\u003c\/strong\u003e\u003cbr\u003eHelps reduce microbial growth inside the unit and may improve long-term internal cleanliness.\u003c\/li\u003e\n\u003cli data-start=\"5797\" data-end=\"5827\"\u003e\n\u003cstrong\u003eExterior Protective Housing\u003c\/strong\u003e\u003cbr\u003eRecommended for outdoor condenser installations.\u003c\/li\u003e\n\u003cli data-start=\"5878\" data-end=\"5903\"\u003e\n\u003cstrong\u003eCondenser Coil Coating\u003c\/strong\u003e\u003cbr\u003eRecommended for coastal or salt-air environments to reduce corrosion risk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583619359,"sku":"S-WKPS8000-220-FD-3","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-platinum-split-8000-ducted-cooling-system-220v-high-efficiency-1187288161.jpg?v=1775520261","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-platinum-split-8000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}