{"product_id":"whisperkool-platinum-split-8000-ductless-cooling-system-220v-high-efficiency","title":"WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency","description":"\u003ch2 data-start=\"0\" data-end=\"109\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Platinum Split 8000 220V High Efficiency Ductless Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"139\" data-end=\"579\"\u003eThe WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency is engineered to provide powerful and efficient temperature control for wine cellars up to approximately \u003cstrong data-start=\"325\" data-end=\"345\"\u003e2,000 cubic feet\u003c\/strong\u003e when properly insulated and sealed. Its ductless split‑system design separates the condenser from the evaporator, allowing for quiet operation inside the cellar while delivering reliable cooling performance from a remote condenser.\u003c\/p\u003e\n\u003cp data-start=\"581\" data-end=\"1045\"\u003eThis high‑efficiency 220V model delivers enhanced energy performance and quieter operation compared to standard voltage units. The evaporator is designed for ceiling‑mount installation, utilizing the natural rise of warm air to improve cooling efficiency and evenly distribute conditioned air throughout the space. The condenser can be placed up to 100 feet away, offering flexible installation options that help minimize noise and maximize usable racking space.\u003c\/p\u003e\n\u003cp data-start=\"1047\" data-end=\"1405\"\u003eInstallation and maintenance are simplified with bottom‑mounted wiring access and flare fittings, making the process more technician‑friendly. Temperature control is precise and user‑friendly via a remote digital thermostat, and an optional liquid‑temperature bottle probe is available for accurate reading of wine temperature rather than just ambient air.\u003c\/p\u003e\n\u003cp data-start=\"1407\" data-end=\"1660\"\u003eWhether you’re outfitting a large residential wine room, commercial cellar, or custom installation, the WhisperKOOL Platinum Split 8000 220V High Efficiency system delivers dependable performance, flexible configuration, and advanced control features.\u003c\/p\u003e\n\u003ch3 data-start=\"692\" data-end=\"749\"\u003e\u003cstrong\u003eIs the Platinum Split 8000 Right for Your Wine Cellar?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"751\" data-end=\"898\"\u003eThe WhisperKOOL Platinum Split 8000 (220V High Efficiency) is designed for \u003cstrong data-start=\"826\" data-end=\"879\"\u003ewine cellars up to approximately 1,750 cubic feet\u003c\/strong\u003e when the space is:\u003c\/p\u003e\n\u003cul data-start=\"900\" data-end=\"1055\"\u003e\n\u003cli data-start=\"900\" data-end=\"919\"\u003eFully insulated\u003c\/li\u003e\n\u003cli data-start=\"920\" data-end=\"958\"\u003eSealed with a proper vapor barrier\u003c\/li\u003e\n\u003cli data-start=\"959\" data-end=\"998\"\u003eProfessionally heat-load calculated\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1055\"\u003eBuilt to standard wine cellar construction practices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1057\" data-end=\"1092\"\u003eThis system is ideal when you need:\u003c\/p\u003e\n\u003cul data-start=\"1094\" data-end=\"1303\"\u003e\n\u003cli data-start=\"1094\" data-end=\"1139\"\u003eA \u003cstrong data-start=\"1098\" data-end=\"1139\"\u003eductless evaporator inside the cellar\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1140\" data-end=\"1197\"\u003eA remotely located condenser (up to 100 line feet away)\u003c\/li\u003e\n\u003cli data-start=\"1198\" data-end=\"1250\"\u003eImproved energy efficiency compared to 110V models\u003c\/li\u003e\n\u003cli data-start=\"1251\" data-end=\"1303\"\u003eQuiet operation with flexible installation options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1305\" data-end=\"1413\"\u003eIf your cellar meets these conditions, this model is often an appropriate mid-to-large residential solution.\u003c\/p\u003e\n\u003ch3 data-start=\"1420\" data-end=\"1460\"\u003e\u003cstrong\u003eWhen You Should NOT Choose This Model\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1462\" data-end=\"1500\"\u003eThis system may not be appropriate if:\u003c\/p\u003e\n\u003cul data-start=\"1502\" data-end=\"1809\"\u003e\n\u003cli data-start=\"1502\" data-end=\"1552\"\u003eThe cellar is not insulated to proper R-values\u003c\/li\u003e\n\u003cli data-start=\"1553\" data-end=\"1607\"\u003eA vapor barrier is missing or improperly installed\u003c\/li\u003e\n\u003cli data-start=\"1608\" data-end=\"1657\"\u003eThe room includes extensive uninsulated glass\u003c\/li\u003e\n\u003cli data-start=\"1658\" data-end=\"1729\"\u003eThe space exceeds 1,750 cubic feet without engineering verification\u003c\/li\u003e\n\u003cli data-start=\"1730\" data-end=\"1809\"\u003eYou require fully concealed cooling (consider a ducted split model instead)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1811\" data-end=\"1949\"\u003eImproper sizing is the most common cause of cooling failure. A professional heat load calculation is strongly recommended before purchase.\u003c\/p\u003e\n\u003ch3 data-start=\"1956\" data-end=\"2007\"\u003e\u003cstrong\u003eHow the Platinum Split 8000 Ductless System Works\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2009\" data-end=\"2070\"\u003eThis is a \u003cstrong data-start=\"2019\" data-end=\"2060\"\u003esplit-system wine cellar cooling unit\u003c\/strong\u003e, meaning:\u003c\/p\u003e\n\u003cul data-start=\"2072\" data-end=\"2220\"\u003e\n\u003cli data-start=\"2072\" data-end=\"2139\"\u003eThe \u003cstrong data-start=\"2078\" data-end=\"2092\"\u003eevaporator\u003c\/strong\u003e is installed inside or adjacent to the cellar.\u003c\/li\u003e\n\u003cli data-start=\"2140\" data-end=\"2220\"\u003eThe \u003cstrong data-start=\"2146\" data-end=\"2159\"\u003econdenser\u003c\/strong\u003e is installed remotely (attic, mechanical room, or outdoors).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2222\" data-end=\"2420\"\u003eThe evaporator delivers cooled air directly into the cellar through a visible grille. Heat is removed through refrigerant lines to the condenser, which may be installed up to \u003cstrong data-start=\"2397\" data-end=\"2419\"\u003e100 line feet away\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2422\" data-end=\"2525\"\u003eThis separation reduces noise and heat transfer inside the cellar while allowing flexible installation.\u003c\/p\u003e\n\u003cp data-start=\"2532\" data-end=\"2564\"\u003e\u003cstrong\u003eCooling Performance \u0026amp; Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2566\" data-end=\"2696\"\u003eCooling output varies depending on condenser air intake temperature. As ambient temperature increases, total BTU output decreases.\u003c\/p\u003e\n\u003cp data-start=\"2698\" data-end=\"2745\"\u003e\u003cstrong\u003ePerformance by Condenser Intake Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Air Intake\u003c\/th\u003e\n\u003cth\u003eSensible BTU\/h\u003c\/th\u003e\n\u003cth\u003eTotal BTU\/h\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003e4,641 – 5,415\u003c\/td\u003e\n\u003ctd\u003e4,834 – 5,521\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e4,427 – 4,839\u003c\/td\u003e\n\u003ctd\u003e4,580 – 4,969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e4,322 – 4,798\u003c\/td\u003e\n\u003ctd\u003e4,479 – 4,879\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"2983\" data-end=\"3095\"\u003e\u003cstrong data-start=\"2983\" data-end=\"2997\"\u003eImportant: \u003c\/strong\u003eThese values assume a fully insulated and sealed cellar with proper vapor barrier construction.\u003c\/p\u003e\n\u003cp data-start=\"3097\" data-end=\"3123\"\u003e\u003cstrong\u003eTemperature Capability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3125\" data-end=\"3316\"\u003e\n\u003cli data-start=\"3125\" data-end=\"3177\"\u003eDesigned to maintain a \u003cstrong data-start=\"3150\" data-end=\"3177\"\u003e55°F cellar temperature\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3178\" data-end=\"3255\"\u003eOperates in environments with condenser intake temperatures up to \u003cstrong data-start=\"3246\" data-end=\"3255\"\u003e120°F\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3256\" data-end=\"3316\"\u003ePerformance depends on insulation quality and construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3323\" data-end=\"3350\"\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cp data-start=\"3352\" data-end=\"3378\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvaporator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3395\" data-end=\"3457\"\u003e\n\u003cli data-start=\"3395\" data-end=\"3401\"\u003e120V\u003c\/li\u003e\n\u003cli data-start=\"3402\" data-end=\"3437\"\u003e15-amp dedicated circuit required\u003c\/li\u003e\n\u003cli data-start=\"3438\" data-end=\"3457\"\u003eRunning Amps: 2.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3459\" data-end=\"3495\"\u003e\u003cstrong\u003eCondenser (220V High Efficiency)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3496\" data-end=\"3574\"\u003e\n\u003cli data-start=\"3496\" data-end=\"3502\"\u003e220V\u003c\/li\u003e\n\u003cli data-start=\"3503\" data-end=\"3538\"\u003e15-amp dedicated circuit required\u003c\/li\u003e\n\u003cli data-start=\"3539\" data-end=\"3550\"\u003eLRA: 13.2\u003c\/li\u003e\n\u003cli data-start=\"3551\" data-end=\"3562\"\u003eRLA: 3.19\u003c\/li\u003e\n\u003cli data-start=\"3563\" data-end=\"3574\"\u003eFLA: 2.66\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3576\" data-end=\"3695\"\u003eProfessional HVAC-R installation is required. Failure to use a qualified technician may void the manufacturer warranty.\u003c\/p\u003e\n\u003ch3 data-start=\"3702\" data-end=\"3731\"\u003e\u003cstrong\u003eLine Set \u0026amp; Distance Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3733\" data-end=\"3914\"\u003e\n\u003cli data-start=\"3733\" data-end=\"3803\"\u003eCondenser may be installed up to \u003cstrong data-start=\"3768\" data-end=\"3785\"\u003e100 line feet\u003c\/strong\u003e from evaporator\u003c\/li\u003e\n\u003cli data-start=\"3804\" data-end=\"3870\"\u003eEvaporator may be installed up to \u003cstrong data-start=\"3840\" data-end=\"3856\"\u003e25 duct feet\u003c\/strong\u003e from cellar\u003c\/li\u003e\n\u003cli data-start=\"3871\" data-end=\"3914\"\u003eDrain line: 1\/2” ID tubing (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3916\" data-end=\"4007\"\u003eImproper line length, poor airflow, or undersized electrical supply can affect performance.\u003c\/p\u003e\n\u003ch2 data-start=\"4014\" data-end=\"4035\"\u003e\u003cstrong\u003eKey System Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4037\" data-end=\"4070\"\u003e\u003cstrong\u003eAdvanced Digital Touch Display\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4071\" data-end=\"4152\"\u003e\n\u003cli data-start=\"4071\" data-end=\"4084\"\u003e50-ft cable\u003c\/li\u003e\n\u003cli data-start=\"4085\" data-end=\"4120\"\u003eBuilt-in system protection alarms\u003c\/li\u003e\n\u003cli data-start=\"4121\" data-end=\"4152\"\u003eMonitors operating parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4154\" data-end=\"4188\"\u003e\u003cstrong\u003eLiquid Temperature Bottle Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"4189\" data-end=\"4325\"\u003eMeasures the temperature of the wine liquid rather than just ambient air, improving temperature accuracy and protecting long-term aging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4327\" data-end=\"4360\"\u003e\u003cstrong\u003e220V High-Efficiency Condenser\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"4361\" data-end=\"4441\"\u003eDesigned for improved electrical performance in larger residential applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4443\" data-end=\"4467\"\u003e\u003cstrong\u003eTwo-Speed Fan Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"4468\" data-end=\"4534\"\u003eAllows adjustment of cooling output based on environmental demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4536\" data-end=\"4577\"\u003e\u003cstrong\u003eOptional 24V Thermostat Conversion Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4578\" data-end=\"4790\"\u003e\n\u003cli data-start=\"4578\" data-end=\"4639\"\u003eAllows integration with customer-supplied smart thermostats\u003c\/li\u003e\n\u003cli data-start=\"4640\" data-end=\"4678\"\u003eEnables remote monitoring and alerts\u003c\/li\u003e\n\u003cli data-start=\"4679\" data-end=\"4742\"\u003eReplaces the standard WhisperKOOL controller and bottle probe\u003c\/li\u003e\n\u003cli data-start=\"4743\" data-end=\"4790\"\u003eWhisperKOOL does not supply smart thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4797\" data-end=\"4810\"\u003e\u003cstrong\u003eNoise Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4812\" data-end=\"4914\"\u003e\n\u003cli data-start=\"4812\" data-end=\"4914\"\u003e\n\u003cp data-start=\"4814\" data-end=\"4914\"\u003e42–46 dBA depending on fan speed\u003cbr data-start=\"4846\" data-end=\"4849\"\u003eQuiet enough for residential installations when properly mounted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4921\" data-end=\"4934\"\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4936\" data-end=\"4944\"\u003e\n\u003cli data-start=\"4936\" data-end=\"4944\"\u003e\n\u003cp data-start=\"4938\" data-end=\"4944\"\u003eR-134a\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4951\" data-end=\"4972\"\u003e\u003cstrong\u003eDimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4974\" data-end=\"4988\"\u003e\u003cstrong\u003eEvaporator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4989\" data-end=\"5039\"\u003e\n\u003cli data-start=\"4989\" data-end=\"5020\"\u003e22.1” L x 22.5” W x 15.5” H\u003c\/li\u003e\n\u003cli data-start=\"5021\" data-end=\"5039\"\u003eWeight: 56 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5041\" data-end=\"5054\"\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"5055\" data-end=\"5089\"\u003e\n\u003cli data-start=\"5055\" data-end=\"5089\"\u003e\n\u003cp data-start=\"5057\" data-end=\"5089\"\u003e21.18” L x 10.75” W x 21.18” H\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eManuals for WhisperKOOL Platinum Split 8000 Ductless:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Owner Manual for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Owner_Manual_6747bc7c-8cd0-4d92-aeb9-561ea97a260c.pdf?v=1646316937\" target=\"_blank\"\u003eOwner Manual for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"H.E. Owner Manual for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/H.E._Owner_Manual_b0f8e5f5-c695-490e-96b1-03fb9133ad35.pdf?v=1646316917\" target=\"_blank\"\u003eH.E. Owner Manual for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"220V High-Efficiency Product Sheets for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/220V_High-Efficiency_Product_Sheets_318a6bee-b230-44b5-bfa2-61fb77486e4c.pdf?v=1646316886\" target=\"_blank\"\u003e220V High-Efficiency Product Sheets for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"High Efficiency 220 Warranty Registration for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Warranty_Checklist-Split_Systems_H.E.-051021.pdf?v=1646259053\" target=\"_blank\"\u003eHigh Efficiency 220 Warranty Registration for WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"5096\" data-end=\"5118\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5120\" data-end=\"5146\"\u003e\u003cstrong\u003eUV-C Light Technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"5147\" data-end=\"5240\"\u003eHelps reduce mold and microbial buildup inside the system.\u003cbr data-start=\"5205\" data-end=\"5208\"\u003e(Not available for Mini models.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5242\" data-end=\"5274\"\u003e\u003cstrong\u003eExterior Protective Housing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5275\" data-end=\"5325\"\u003eRecommended for outdoor condenser installations.\u003c\/p\u003e\n\u003cul data-start=\"5326\" data-end=\"5420\"\u003e\n\u003cli data-start=\"5326\" data-end=\"5351\"\u003eGalvanized steel base\u003c\/li\u003e\n\u003cli data-start=\"5352\" data-end=\"5375\"\u003e20 GA steel cabinet\u003c\/li\u003e\n\u003cli data-start=\"5376\" data-end=\"5393\"\u003eHinged access\u003c\/li\u003e\n\u003cli data-start=\"5394\" data-end=\"5420\"\u003eRain trough protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5422\" data-end=\"5449\"\u003e\u003cstrong\u003eCondenser Coil Coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"5450\" data-end=\"5524\"\u003eRecommended for coastal or salt-air environments to reduce corrosion risk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"5531\" data-end=\"5541\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5543\" data-end=\"5629\"\u003e\n\u003cli data-start=\"5543\" data-end=\"5590\"\u003eTwo-Year Limited Warranty (Parts and Labor)\u003c\/li\u003e\n\u003cli data-start=\"5591\" data-end=\"5629\"\u003eProfessional installation required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7402\" data-end=\"7444\"\u003e\u003cstrong\u003eProfessional Sizing Assistance Available\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7446\" data-end=\"7705\"\u003eChoosing the correct cooling system is critical to protecting your wine collection. If you are unsure whether the Platinum Split 8000 is appropriate for your project, our cooling specialists can review your cellar specifications and assist with proper sizing.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583717663,"sku":"S-WKPS8000-220-WM-3","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-platinum-split-8000-ductless-cooling-system-220v-high-efficiency-1187288195.jpg?v=1775520264","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-platinum-split-8000-ductless-cooling-system-220v-high-efficiency","provider":"The Imperial Luxe","version":"1.0","type":"link"}