{"product_id":"whisperkool-platinum-split-8000-omega-110v-ducted-wine-cellar-cooling-systems","title":"WhisperKOOL Platinum Split 8000 OMEGA 110V Ducted Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"99\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Platinum Split 8000 OMEGA 110V Ducted Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"129\" data-end=\"602\"\u003eThe WhisperKOOL Platinum Split 8000 OMEGA 110V Ducted Wine Cellar Cooling System is a premium cooling solution engineered for large wine cellars up to approximately \u003cstrong data-start=\"294\" data-end=\"314\"\u003e1,750 cubic feet\u003c\/strong\u003e. Designed with a fully ducted split-system configuration, this unit allows both the evaporator and condenser to be installed remotely, ensuring a quiet, clutter-free cellar environment while maintaining consistent and reliable temperature control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"961\"\u003eThis system delivers efficient performance using eco-friendly refrigerant technology while maintaining stable cellar conditions ideal for long-term wine storage and aging. The ducted design keeps all equipment hidden from view, maximizing usable storage space and enhancing the overall aesthetics of your wine cellar. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"963\" data-end=\"1316\"\u003eEquipped with advanced digital controls and a liquid-temperature bottle probe, the unit provides precise monitoring and adjustment of cellar conditions. Its flexible installation supports condenser placement up to 100 feet away, offering adaptability for both residential and commercial wine storage applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1318\" data-end=\"1636\"\u003eBuilt with durability in mind, the Platinum Split 8000 OMEGA features heavy-duty components, quiet operation, and cold ambient protection for reliable year-round performance. It is a dependable solution for wine collectors seeking efficient, discreet, and high-capacity cooling.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3 data-start=\"1352\" data-end=\"1403\"\u003e\u003cstrong\u003eIs This the Right Cooling System for Your Cellar?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1405\" data-end=\"1443\"\u003e\u003cstrong\u003eChoose the Platinum Split 8000 if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1445\" data-end=\"1775\"\u003e\n\u003cli data-start=\"1445\" data-end=\"1494\"\u003eYour cellar is between 1,000–1,750 cubic feet\u003c\/li\u003e\n\u003cli data-start=\"1495\" data-end=\"1570\"\u003eYou want a fully ducted system with no visible grille inside the cellar\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1637\"\u003eYour project includes glass walls or high heat load conditions\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1723\"\u003eYou need the condenser installed in a mechanical room, attic, garage, or outdoors\u003c\/li\u003e\n\u003cli data-start=\"1724\" data-end=\"1775\"\u003eYou require higher BTU output for warm climates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1777\" data-end=\"1810\"\u003e\u003cstrong\u003eDo NOT Choose This System if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1812\" data-end=\"2036\"\u003e\n\u003cli data-start=\"1812\" data-end=\"1860\"\u003eThe cellar is not fully insulated and sealed\u003c\/li\u003e\n\u003cli data-start=\"1861\" data-end=\"1890\"\u003eThere is no vapor barrier\u003c\/li\u003e\n\u003cli data-start=\"1891\" data-end=\"1957\"\u003eYou plan to self-install without licensed HVAC-R certification\u003c\/li\u003e\n\u003cli data-start=\"1958\" data-end=\"2036\"\u003eThe space is smaller than 1,000 cubic feet (consider the 4000 model instead)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2043\" data-end=\"2085\"\u003e\u003cstrong\u003eHow the Ducted Split Configuration Works\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2087\" data-end=\"2183\"\u003eThe Platinum Split 8000 consists of two separate components connected by a refrigerant line set:\u003c\/p\u003e\n\u003cp data-start=\"2185\" data-end=\"2215\"\u003e\u003cstrong\u003eEvaporator (Fan Coil Unit)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2216\" data-end=\"2385\"\u003e\n\u003cli data-start=\"2216\" data-end=\"2260\"\u003eInstalled inside or adjacent to the cellar\u003c\/li\u003e\n\u003cli data-start=\"2261\" data-end=\"2291\"\u003eDucted supply and return air\u003c\/li\u003e\n\u003cli data-start=\"2292\" data-end=\"2341\"\u003eBottle probe for liquid temperature measurement\u003c\/li\u003e\n\u003cli data-start=\"2342\" data-end=\"2385\"\u003eAdvanced digital thermostat (50 ft cable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2387\" data-end=\"2406\"\u003e\u003cstrong\u003eCondensing Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2407\" data-end=\"2573\"\u003e\n\u003cli data-start=\"2407\" data-end=\"2454\"\u003eInstalled remotely (up to 100 line feet away)\u003c\/li\u003e\n\u003cli data-start=\"2455\" data-end=\"2533\"\u003eCan be located in attic, garage, mechanical room, or outdoors (with housing)\u003c\/li\u003e\n\u003cli data-start=\"2534\" data-end=\"2573\"\u003eDesigned for high ambient performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2575\" data-end=\"2722\"\u003eBecause the system is fully ducted, the cooling equipment remains concealed, making it ideal for luxury wine walls and architectural installations.\u003c\/p\u003e\n\u003cp data-start=\"2729\" data-end=\"2773\"\u003e\u003cstrong\u003eCooling Performance by Ambient Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2775\" data-end=\"2931\"\u003eCooling output varies based on condenser air intake temperature. Systems must be sized according to peak summer conditions — not average yearly temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2575\" data-end=\"2722\"\u003e\u003cstrong\u003ePlatinum Split 8000 BTU\/h Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Air Temp\u003c\/th\u003e\n\u003cth\u003eMedium Fan (Sensible \/ Total)\u003c\/th\u003e\n\u003cth\u003eHigh Fan (Sensible \/ Total)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003e4641 \/ 5415\u003c\/td\u003e\n\u003ctd\u003e5028 \/ 5521\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e4427 \/ 4839\u003c\/td\u003e\n\u003ctd\u003e4580 \/ 4969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e4322 \/ 4798\u003c\/td\u003e\n\u003ctd\u003e4479 \/ 4879\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"2575\" data-end=\"2722\"\u003e\u003cstrong\u003eMaximum Performance:\u003c\/strong\u003e Maintains 55°F cellar temperature with up to 120°F condenser air intake.\u003c\/p\u003e\n\u003ch2 data-start=\"3502\" data-end=\"3528\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"3530\" data-end=\"3724\"\u003e\n\u003cstrong data-start=\"3530\" data-end=\"3540\"\u003eModel:\u003c\/strong\u003e Platinum Split 8000 OMEGA 110V\u003c\/li\u003e\n\u003cli data-start=\"3530\" data-end=\"3724\"\u003e\n\u003cstrong data-start=\"3574\" data-end=\"3602\"\u003eRecommended Cellar Size:\u003c\/strong\u003e Up to 1,750 cu. ft.*\u003c\/li\u003e\n\u003cli data-start=\"3530\" data-end=\"3724\"\u003e\n\u003cstrong data-start=\"3626\" data-end=\"3642\"\u003eRefrigerant:\u003c\/strong\u003e R-134a\u003c\/li\u003e\n\u003cli data-start=\"3530\" data-end=\"3724\"\u003e\n\u003cstrong data-start=\"3652\" data-end=\"3667\"\u003eFan Speeds:\u003c\/strong\u003e Medium \/ High\u003c\/li\u003e\n\u003cli data-start=\"3530\" data-end=\"3724\"\u003e\n\u003cstrong data-start=\"3684\" data-end=\"3692\"\u003eCFM:\u003c\/strong\u003e 200\u003c\/li\u003e\n\u003cli data-start=\"3530\" data-end=\"3724\"\u003e\n\u003cstrong data-start=\"3699\" data-end=\"3714\"\u003eHorsepower:\u003c\/strong\u003e 0.5+ HP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3731\" data-end=\"3744\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3746\" data-end=\"3833\"\u003e\n\u003cli data-start=\"3746\" data-end=\"3790\"\u003e\n\u003cstrong data-start=\"3748\" data-end=\"3763\"\u003eEvaporator:\u003c\/strong\u003e 22.1”L x 22.5”W x 15.5”H\u003c\/li\u003e\n\u003cli data-start=\"3791\" data-end=\"3833\"\u003e\n\u003cstrong data-start=\"3793\" data-end=\"3807\"\u003eCondenser:\u003c\/strong\u003e 23”L x 15.75”W x 15.3”H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3840\" data-end=\"3866\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3868\" data-end=\"4017\"\u003e\n\u003cli data-start=\"3868\" data-end=\"3928\"\u003e\n\u003cstrong data-start=\"3870\" data-end=\"3885\"\u003eEvaporator:\u003c\/strong\u003e 120V (15-amp dedicated circuit required)\u003c\/li\u003e\n\u003cli data-start=\"3929\" data-end=\"3952\"\u003e\n\u003cstrong data-start=\"3931\" data-end=\"3945\"\u003eCondenser:\u003c\/strong\u003e 120V\u003c\/li\u003e\n\u003cli data-start=\"3953\" data-end=\"3989\"\u003e\n\u003cstrong data-start=\"3955\" data-end=\"3983\"\u003eEvaporator Running Amps:\u003c\/strong\u003e 2.2\u003c\/li\u003e\n\u003cli data-start=\"3990\" data-end=\"4017\"\u003e\n\u003cstrong data-start=\"3992\" data-end=\"4011\"\u003eCondenser Amps:\u003c\/strong\u003e 9.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4019\" data-end=\"4079\"\u003eDedicated circuits are required for proper system operation.\u003c\/p\u003e\n\u003ch3 data-start=\"4348\" data-end=\"4372\"\u003e\u003cstrong\u003eLine Set Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4374\" data-end=\"4483\"\u003e\n\u003cli data-start=\"4374\" data-end=\"4398\"\u003eLiquid line: 1\/4” OD\u003c\/li\u003e\n\u003cli data-start=\"4399\" data-end=\"4483\"\u003eSuction line:\n\u003cul data-start=\"4419\" data-end=\"4483\"\u003e\n\u003cli data-start=\"4419\" data-end=\"4448\"\u003e1\/2” OD (less than 50 ft)\u003c\/li\u003e\n\u003cli data-start=\"4451\" data-end=\"4483\"\u003e5\/8” OD (greater than 50 ft)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4485\" data-end=\"4517\"\u003eMaximum line set length: 100 ft.\u003c\/p\u003e\n\u003ch3 data-start=\"4524\" data-end=\"4537\"\u003e\u003cstrong\u003eDrain Line\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4539\" data-end=\"4615\"\u003e\n\u003cli data-start=\"4539\" data-end=\"4586\"\u003e1\/2” ID clear plastic tubing (not included)\u003c\/li\u003e\n\u003cli data-start=\"4587\" data-end=\"4615\"\u003eRigid tubing recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKool Ducted Platinum Split 8000 OMEGA:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Platinum_Split_4K_8K_TM_012524_1.pdf?v=1738699323\" title=\"Platinum Split Owner's Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan\u003ePlatinum Split Owner's Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Platinum Split Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/ProductSheet_R1.pdf?v=1738692821\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Platinum Split Product Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Ducted Platinum Split Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Ducted_Platinum_Split_Series_ProductSheet_R1-min.pdf?v=1738702755\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Ducted Platinum Split Product Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Condenser Owner's Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Omega_Condenser_OM_110424_1.pdf?v=1738692728\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Condenser Owner's Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Condenser Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/ProductSheet_R1.pdf?v=1738692821\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Condenser Product Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"4622\" data-end=\"4660\"\u003e\u003cstrong\u003eInstallation Requirements (Critical)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4662\" data-end=\"4789\"\u003eThis system MUST be installed by a qualified, licensed HVAC-R technician.\u003cbr data-start=\"4735\" data-end=\"4738\"\u003eFailure to do so voids the manufacturer’s warranty.\u003c\/p\u003e\n\u003cp\u003eFor proper operation, the wine cellar must include:\u003c\/p\u003e\n\u003cul data-start=\"4844\" data-end=\"5022\"\u003e\n\u003cli data-start=\"4844\" data-end=\"4876\"\u003eMinimum R-19 wall insulation\u003c\/li\u003e\n\u003cli data-start=\"4877\" data-end=\"4912\"\u003eMinimum R-30 ceiling insulation\u003c\/li\u003e\n\u003cli data-start=\"4913\" data-end=\"4963\"\u003e6-mil vapor barrier on warm side of insulation\u003c\/li\u003e\n\u003cli data-start=\"4964\" data-end=\"4989\"\u003eAirtight construction\u003c\/li\u003e\n\u003cli data-start=\"4990\" data-end=\"5022\"\u003eDedicated electrical circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImproper construction may cause:\u003c\/p\u003e\n\u003cul data-start=\"5058\" data-end=\"5169\"\u003e\n\u003cli data-start=\"5058\" data-end=\"5080\"\u003eContinuous cycling\u003c\/li\u003e\n\u003cli data-start=\"5081\" data-end=\"5109\"\u003eFailure to maintain 55°F\u003c\/li\u003e\n\u003cli data-start=\"5110\" data-end=\"5137\"\u003eExcess humidity or mold\u003c\/li\u003e\n\u003cli data-start=\"5138\" data-end=\"5169\"\u003ePremature equipment failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5171\" data-end=\"5257\"\u003eHeat load calculations should always be performed prior to selecting a cooling system.\u003c\/p\u003e\n\u003ch3 data-end=\"5291\" data-start=\"5264\"\u003e\u003cstrong\u003eAdvanced Control Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"5492\" data-start=\"5293\"\u003e\n\u003cli data-end=\"5341\" data-start=\"5293\"\u003eAdvanced digital thermostat with 50 ft cable\u003c\/li\u003e\n\u003cli data-end=\"5401\" data-start=\"5342\"\u003eLiquid-temperature measuring bottle probe (50 ft cable)\u003c\/li\u003e\n\u003cli data-end=\"5446\" data-start=\"5402\"\u003e24V thermostat conversion kit (optional)\u003c\/li\u003e\n\u003cli data-end=\"5492\" data-start=\"5447\"\u003eUV-C lighting system (optional accessory)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"5603\" data-start=\"5494\"\u003eThe bottle probe monitors actual liquid temperature rather than air temperature for improved aging stability.\u003c\/p\u003e\n\u003ch3 data-end=\"5620\" data-start=\"5610\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"5759\" data-start=\"5622\"\u003e\n\u003cli data-end=\"5651\" data-start=\"5622\"\u003eTwo-year limited warranty\u003c\/li\u003e\n\u003cli data-end=\"5705\" data-start=\"5652\"\u003eAdditional one-year grace period for installation\u003c\/li\u003e\n\u003cli data-end=\"5759\" data-start=\"5706\"\u003eParts and labor coverage (manufacturer terms apply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"5171\" data-end=\"5257\"\u003e\u003cstrong\u003eChoosing Between Platinum Split 8000 and 4000\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eScenario\u003c\/th\u003e\n\u003cth\u003eChoose 8000\u003c\/th\u003e\n\u003cth\u003eChoose 4000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver 1,000 cu ft\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✖\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh ambient temperatures\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003eLimited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass walls\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003eMaybe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall residential cellar\u003c\/td\u003e\n\u003ctd\u003e✖\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"5171\" data-end=\"5257\"\u003eIf your cellar exceeds 1,000 cubic feet or experiences high heat load conditions, the 8000 model is typically required.\u003c\/p\u003e\n\u003ch3 data-start=\"7216\" data-end=\"7225\"\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"7227\" data-end=\"7537\"\u003eThe WhisperKool Ducted Platinum Split 8000 OMEGA 110V is engineered for large, fully insulated wine cellars that require concealed cooling and high ambient performance. When properly sized and professionally installed, it delivers stable 55°F storage conditions while keeping mechanical equipment out of sight.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583291679,"sku":"S-WKPS8000-OMEGA-FD","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-ducted-platinum-split-8000-omega-110v-wine-cooling-unit-1187288031.jpg?v=1775520254","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-platinum-split-8000-omega-110v-ducted-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}