{"product_id":"whisperkool-platinum-split-8000-omega-110v-ductless-wine-cellar-cooling-systems","title":"WhisperKOOL Platinum Split 8000 OMEGA 110V Ductless Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"101\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Platinum Split 8000 OMEGA 110V Ductless Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"131\" data-end=\"603\"\u003eThe WhisperKOOL Platinum Split 8000 OMEGA 110V Ductless Wine Cellar Cooling System is a high-capacity solution designed to deliver reliable, quiet, and efficient climate control for large wine cellars up to approximately \u003cstrong data-start=\"352\" data-end=\"372\"\u003e1,750 cubic feet\u003c\/strong\u003e. Its ductless split configuration separates the evaporator and condenser, allowing for flexible installation and reduced noise inside the cellar while maintaining optimal storage conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"605\" data-end=\"955\"\u003eEngineered for both residential and commercial applications, this system provides consistent temperature management essential for proper wine aging. The ductless design ensures a clean and space-saving installation, while advanced cooling technology supports stable performance even under demanding conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"957\" data-end=\"1316\"\u003eWith energy-efficient operation and precision temperature control, the Platinum Split 8000 OMEGA helps reduce power consumption while maintaining ideal cellar environments. Its quiet, low-vibration performance enhances the overall experience, making it suitable for installations where minimal disturbance is important. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1318\" data-end=\"1610\"\u003eBuilt for durability and long-term reliability, this system is trusted for maintaining consistent wine storage conditions. Whether for a private collection or commercial wine storage, it offers dependable performance with flexible installation options.\u003c\/p\u003e\n\u003cp data-end=\"481\" data-start=\"407\"\u003e\u003cstrong\u003eIs the WhisperKool Platinum Split 8000 OMEGA Right for Your Wine Cellar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"657\" data-start=\"483\"\u003eThe Platinum Split 8000 OMEGA is a high-capacity \u003cstrong data-end=\"570\" data-start=\"532\"\u003eductless split wine cooling system\u003c\/strong\u003e designed for properly constructed wine cellars between \u003cstrong data-end=\"656\" data-start=\"626\"\u003e1,200 and 1,750 cubic feet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"804\" data-start=\"659\"\u003eIt separates the evaporator (inside the cellar) from the condensing unit (remote location), reducing noise and heat buildup inside the wine room.\u003c\/p\u003e\n\u003cp data-end=\"832\" data-start=\"806\"\u003eThis system is ideal when:\u003c\/p\u003e\n\u003cul data-end=\"1073\" data-start=\"834\"\u003e\n\u003cli data-end=\"884\" data-start=\"834\"\u003eThe cellar is fully insulated and vapor sealed\u003c\/li\u003e\n\u003cli data-end=\"935\" data-start=\"885\"\u003eQuiet operation inside the cellar is important\u003c\/li\u003e\n\u003cli data-end=\"970\" data-start=\"936\"\u003eA ducted system is not desired\u003c\/li\u003e\n\u003cli data-end=\"1025\" data-start=\"971\"\u003eThe condenser can be installed up to 100 feet away\u003c\/li\u003e\n\u003cli data-end=\"1073\" data-start=\"1026\"\u003eProfessional HVAC installation is available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ch4 data-end=\"1104\" data-start=\"1080\"\u003e\u003cstrong\u003eWho This System Is For\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-end=\"1146\" data-start=\"1106\"\u003eChoose the Platinum Split 8000 OMEGA if:\u003c\/p\u003e\n\u003cul data-end=\"1432\" data-start=\"1148\"\u003e\n\u003cli data-end=\"1186\" data-start=\"1148\"\u003eYour cellar is 1,200–1,750 cu. ft.\u003c\/li\u003e\n\u003cli data-end=\"1250\" data-start=\"1187\"\u003eYou have R-19+ wall insulation and R-30+ ceiling insulation\u003c\/li\u003e\n\u003cli data-end=\"1300\" data-start=\"1251\"\u003eA vapor barrier is installed on the warm side\u003c\/li\u003e\n\u003cli data-end=\"1329\" data-start=\"1301\"\u003eThe door is fully sealed\u003c\/li\u003e\n\u003cli data-end=\"1378\" data-start=\"1330\"\u003eYou want compressor noise outside the cellar\u003c\/li\u003e\n\u003cli data-end=\"1432\" data-start=\"1379\"\u003eYou are working with a licensed HVAC-R technician\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"1476\" data-start=\"1439\"\u003e\u003cstrong\u003eWhen This System Is NOT Appropriate\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-end=\"1505\" data-start=\"1478\"\u003eDo not select this unit if:\u003c\/p\u003e\n\u003cul data-end=\"1741\" data-start=\"1507\"\u003e\n\u003cli data-end=\"1543\" data-start=\"1507\"\u003eThe cellar exceeds 1,750 cu. ft.\u003c\/li\u003e\n\u003cli data-end=\"1585\" data-start=\"1544\"\u003eThe room shares air with living space\u003c\/li\u003e\n\u003cli data-end=\"1619\" data-start=\"1586\"\u003eNo vapor barrier is installed\u003c\/li\u003e\n\u003cli data-end=\"1665\" data-start=\"1620\"\u003eInsulation is below recommended standards\u003c\/li\u003e\n\u003cli data-end=\"1696\" data-start=\"1666\"\u003eYou intend to self-install\u003c\/li\u003e\n\u003cli data-end=\"1741\" data-start=\"1697\"\u003eThe condenser location lacks ventilation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1835\" data-start=\"1743\"\u003eImproper construction or installation will reduce cooling performance and void the warranty.\u003c\/p\u003e\n\u003ch3 data-end=\"1890\" data-start=\"1842\"\u003e\u003cstrong\u003eHow a Ductless Split Wine Cooling System Works\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1931\" data-start=\"1892\"\u003eThe system uses two primary components:\u003c\/p\u003e\n\u003cp data-end=\"1977\" data-start=\"1933\"\u003e\u003cstrong\u003eEvaporator (Installed Inside the Cellar)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2163\" data-start=\"1978\"\u003e\n\u003cli data-end=\"2024\" data-start=\"1978\"\u003ePulls warm cellar air across cooling coils\u003c\/li\u003e\n\u003cli data-end=\"2059\" data-start=\"2025\"\u003eRemoves heat using refrigerant\u003c\/li\u003e\n\u003cli data-end=\"2094\" data-start=\"2060\"\u003eReturns conditioned air evenly\u003c\/li\u003e\n\u003cli data-end=\"2163\" data-start=\"2095\"\u003eUses a liquid-temperature bottle probe for precise aging control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2205\" data-start=\"2165\"\u003e\u003cstrong\u003eCondensing Unit (Installed Remotely)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2376\" data-start=\"2206\"\u003e\n\u003cli data-end=\"2242\" data-start=\"2206\"\u003eReleases heat outside the cellar\u003c\/li\u003e\n\u003cli data-end=\"2338\" data-start=\"2243\"\u003eCan be installed in a garage, attic, mechanical room, or outdoors (with proper ventilation)\u003c\/li\u003e\n\u003cli data-end=\"2376\" data-start=\"2339\"\u003eConnected by refrigerant line set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2477\" data-start=\"2378\"\u003eSeparating these components keeps compressor noise out of the cellar and improves acoustic comfort.\u003c\/p\u003e\n\u003ch3 data-end=\"2524\" data-start=\"2484\"\u003e\u003cstrong\u003eCooling Capacity \u0026amp; Ambient Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2547\" data-start=\"2526\"\u003e\u003cstrong\u003eRated Cellar Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"2574\" data-start=\"2548\"\u003eUp to \u003cstrong data-end=\"2571\" data-start=\"2554\"\u003e1,750 cu. ft.\u003c\/strong\u003e*\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2681\" data-start=\"2576\"\u003e*Based on a fully insulated and sealed cellar with proper vapor barrier and no excessive glass exposure.\u003c\/p\u003e\n\u003ch3 data-end=\"2681\" data-start=\"2576\"\u003e\u003cstrong\u003eBTU Performance by Condenser Air Intake Temperature\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Air Intake\u003c\/th\u003e\n\u003cth\u003eSensible BTU\u003c\/th\u003e\n\u003cth\u003eTotal BTU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003e4,814\u003c\/td\u003e\n\u003ctd\u003e5,687\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e4,455\u003c\/td\u003e\n\u003ctd\u003e4,997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e4,370\u003c\/td\u003e\n\u003ctd\u003e4,834\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-start=\"2924\" data-end=\"2948\"\u003e\u003cstrong\u003eWhy Capacity Changes\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"2950\" data-end=\"3115\"\u003eCooling capacity decreases as condenser intake temperature increases.\u003cbr data-start=\"3019\" data-end=\"3022\"\u003eIf your condenser is installed in a hot garage or attic, effective cooling output is reduced.\u003c\/p\u003e\n\u003cp data-start=\"3117\" data-end=\"3168\"\u003eAlways size based on worst-case ambient conditions.\u003c\/p\u003e\n\u003ch4 data-start=\"3175\" data-end=\"3205\"\u003e\u003cstrong\u003eMaximum Operating Condition\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"3207\" data-end=\"3376\"\u003eThe system can maintain a \u003cstrong data-start=\"3233\" data-end=\"3260\"\u003e55°F cellar temperature\u003c\/strong\u003e with condenser air intake temperatures up to \u003cstrong data-start=\"3306\" data-end=\"3315\"\u003e120°F\u003c\/strong\u003e, provided cellar insulation and sealing meet specifications.\u003c\/p\u003e\n\u003ch3 data-start=\"3383\" data-end=\"3423\"\u003e\u003cstrong\u003eRequired Cellar Construction Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3425\" data-end=\"3454\"\u003eTo achieve rated performance:\u003c\/p\u003e\n\u003cul data-start=\"3456\" data-end=\"3645\"\u003e\n\u003cli data-start=\"3456\" data-end=\"3488\"\u003eMinimum R-19 wall insulation\u003c\/li\u003e\n\u003cli data-start=\"3489\" data-end=\"3524\"\u003eMinimum R-30 ceiling insulation\u003c\/li\u003e\n\u003cli data-start=\"3525\" data-end=\"3561\"\u003e6-mil vapor barrier on warm side\u003c\/li\u003e\n\u003cli data-start=\"3562\" data-end=\"3584\"\u003eAirtight door seal\u003c\/li\u003e\n\u003cli data-start=\"3585\" data-end=\"3613\"\u003eNo HVAC air infiltration\u003c\/li\u003e\n\u003cli data-start=\"3614\" data-end=\"3645\"\u003eNo open floor plan exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3647\" data-end=\"3704\"\u003eWithout these standards, system performance will decline.\u003c\/p\u003e\n\u003ch3 data-start=\"3711\" data-end=\"3736\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3738\" data-end=\"3863\"\u003e\n\u003cli data-start=\"3738\" data-end=\"3798\"\u003e\n\u003cstrong data-start=\"3740\" data-end=\"3755\"\u003eEvaporator:\u003c\/strong\u003e 120V (15-amp dedicated circuit required)\u003c\/li\u003e\n\u003cli data-start=\"3799\" data-end=\"3863\"\u003e\n\u003cstrong data-start=\"3801\" data-end=\"3815\"\u003eCondenser:\u003c\/strong\u003e 120V (separate dedicated circuit recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3865\" data-end=\"3906\"\u003eRunning Amps: 2.2\u003c\/p\u003e\n\u003cp data-start=\"3865\" data-end=\"3906\"\u003eCompressor: LRA 9.5\u003c\/p\u003e\n\u003cp data-start=\"3908\" data-end=\"4020\"\u003eElectrical work should be performed by a licensed electrician. Improper breaker sizing may cause nuisance trips.\u003c\/p\u003e\n\u003ch3 data-start=\"4027\" data-end=\"4064\"\u003e\u003cstrong\u003eRefrigerant \u0026amp; Line Set Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4066\" data-end=\"4228\"\u003e\n\u003cli data-start=\"4066\" data-end=\"4089\"\u003eRefrigerant: R-134a\u003c\/li\u003e\n\u003cli data-start=\"4090\" data-end=\"4114\"\u003eLiquid Line: 1\/4\" OD\u003c\/li\u003e\n\u003cli data-start=\"4115\" data-end=\"4195\"\u003eSuction Line:\n\u003cul data-start=\"4135\" data-end=\"4195\"\u003e\n\u003cli data-start=\"4135\" data-end=\"4162\"\u003e1\/2\" (less than 50 ft.)\u003c\/li\u003e\n\u003cli data-start=\"4165\" data-end=\"4195\"\u003e5\/8\" (greater than 50 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4196\" data-end=\"4228\"\u003eMaximum line length: 100 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4230\" data-end=\"4306\"\u003eImproper line sizing or charging will reduce efficiency and system lifespan.\u003c\/p\u003e\n\u003ch3 data-start=\"4313\" data-end=\"4378\"\u003e\u003cstrong\u003eInstallation Requirements (Professional Installation Mandatory)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4380\" data-end=\"4392\"\u003eThis system:\u003c\/p\u003e\n\u003cul data-start=\"4394\" data-end=\"4586\"\u003e\n\u003cli data-start=\"4394\" data-end=\"4416\"\u003eIs not pre-charged\u003c\/li\u003e\n\u003cli data-start=\"4417\" data-end=\"4450\"\u003eRequires refrigerant handling\u003c\/li\u003e\n\u003cli data-start=\"4451\" data-end=\"4491\"\u003eMust be vacuumed and pressure tested\u003c\/li\u003e\n\u003cli data-start=\"4492\" data-end=\"4520\"\u003eMust be properly charged\u003c\/li\u003e\n\u003cli data-start=\"4521\" data-end=\"4548\"\u003eRequires flare fittings\u003c\/li\u003e\n\u003cli data-start=\"4549\" data-end=\"4586\"\u003eRequires condensate drain routing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4588\" data-end=\"4694\"\u003e\u003cstrong data-start=\"4588\" data-end=\"4649\"\u003eInstallation by a licensed HVAC-R technician is required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4588\" data-end=\"4694\"\u003eFailure to comply voids warranty coverage.\u003c\/p\u003e\n\u003ch3 data-start=\"4588\" data-end=\"4694\"\u003e\u003cstrong\u003eNoise Levels\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003edBA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator\u003c\/td\u003e\n\u003ctd\u003e56–62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser\u003c\/td\u003e\n\u003ctd\u003e46–52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eSplit configuration keeps compressor noise outside the cellar.\u003c\/p\u003e\n\u003ch2 data-start=\"4873\" data-end=\"4911\"\u003e\u003cstrong\u003eDimensions \u0026amp; Physical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"4913\" data-end=\"4927\"\u003e\u003cstrong\u003eEvaporator\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"4928\" data-end=\"4974\"\u003e16.1\" L x 20.5\" W x 15.5\" H\u003c\/li\u003e\n\u003cli data-start=\"4928\" data-end=\"4974\"\u003eWeight: 54 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4976\" data-end=\"4989\"\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"4990\" data-end=\"5035\"\u003e23\" L x 15.75\" W x 15.3\" H\u003c\/li\u003e\n\u003cli data-start=\"4990\" data-end=\"5035\"\u003eWeight: 86 lbs\u003c\/li\u003e\n\u003cli data-start=\"5037\" data-end=\"5105\"\u003eHorsepower: 0.5+ HP\u003c\/li\u003e\n\u003cli data-start=\"5037\" data-end=\"5105\"\u003eDrain Line: 1\/2\" ID rigid tubing recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKool Ductless Platinum Split 8000:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Platinum_Split_4K_8K_TM_012524_1.pdf?v=1738699323\" title=\"Platinum Split Owner's Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan\u003ePlatinum Split Owner's Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Platinum Split Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/ProductSheet_R1.pdf?v=1738692821\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Platinum Split Product Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Ductless_Platinum_Split_Series_ProductSheet_R1.pdf?v=1738695402\" title=\"OMEGA DUCTLESS Platinum Split Product Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA DUCTLESS Platinum Split Product Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Condenser Owner's Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Omega_Condenser_OM_110424_1.pdf?v=1738692728\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Condenser Owner's Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"OMEGA Condenser Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/ProductSheet_R1.pdf?v=1738692821\" target=\"_blank\"\u003e\u003cspan\u003eOMEGA Condenser Product Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"5112\" data-end=\"5146\"\u003e\u003cstrong\u003eThermostat \u0026amp; Temperature Control\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"5148\" data-end=\"5247\"\u003e\n\u003cli data-start=\"5148\" data-end=\"5176\"\u003eAdvanced digital display\u003c\/li\u003e\n\u003cli data-start=\"5177\" data-end=\"5204\"\u003e50 ft. thermostat cable\u003c\/li\u003e\n\u003cli data-start=\"5205\" data-end=\"5247\"\u003e50 ft. liquid-temperature bottle probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5249\" data-end=\"5370\"\u003eThe bottle probe measures liquid temperature rather than ambient air, helping maintain more stable wine aging conditions.\u003c\/p\u003e\n\u003cp data-start=\"5249\" data-end=\"5370\"\u003e\u003cstrong\u003ePlatinum Split 4000 vs 8000 – Which Should You Choose?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003ePlatinum 4000\u003c\/th\u003e\n\u003cth\u003ePlatinum 8000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cellar Size\u003c\/td\u003e\n\u003ctd\u003e1,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e1,750 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Load Tolerance\u003c\/td\u003e\n\u003ctd\u003eModerate\u003c\/td\u003e\n\u003ctd\u003eHigh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Wall Applications\u003c\/td\u003e\n\u003ctd\u003eLimited\u003c\/td\u003e\n\u003ctd\u003eMore Suitable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarger Commercial Use\u003c\/td\u003e\n\u003ctd\u003eNot Ideal\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"5249\" data-end=\"5370\"\u003eIf your cellar exceeds 1,200 cu. ft., has glass exposure, or has higher ambient condenser conditions, the 8000 model is typically recommended.\u003c\/p\u003e\n\u003ch3 data-start=\"5866\" data-end=\"5876\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5878\" data-end=\"5991\"\u003eTwo-year limited warranty\u003c\/p\u003e\n\u003cp data-start=\"5878\" data-end=\"5991\"\u003eIncludes up to an additional one-year grace period for installation (parts and labor)\u003c\/p\u003e\n\u003cp data-start=\"5993\" data-end=\"6047\"\u003eWarranty is void without licensed HVAC-R installation.\u003c\/p\u003e\n\u003ch3 data-start=\"6054\" data-end=\"6076\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"6078\" data-end=\"6136\"\u003e\n\u003cli data-start=\"6078\" data-end=\"6111\"\u003e24V Thermostat Conversion Kit\u003c\/li\u003e\n\u003cli data-start=\"6112\" data-end=\"6136\"\u003eUV-C Lighting System\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583324447,"sku":"S-WKPS8000-OMEGA-WM","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-ductless-platinum-split-8000-omega-110v-wine-cellar-cooling-system-1187288041.jpg?v=1775520254","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-platinum-split-8000-omega-110v-ductless-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}