{"product_id":"whisperkool-platinum-split-twin-220v-high-efficiency-ducted-wine-cellar-cooling-systems","title":"WhisperKOOL Platinum Split Twin 220V High Efficiency Ducted Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"107\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Platinum Split Twin 220V High Efficiency Ducted Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"137\" data-end=\"654\"\u003eThe WhisperKOOL Platinum Split Twin 220V High Efficiency Ducted Cooling System is a high‑performance solution engineered for large residential and commercial wine cellars up to approximately \u003cstrong data-start=\"328\" data-end=\"348\"\u003e3,000 cubic feet\u003c\/strong\u003e when properly insulated and sealed with a vapor barrier. Its split system configuration separates the evaporator and condenser components, allowing quiet, efficient operation inside the cellar while placing the condenser remotely for reduced sound and heat buildup. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"656\" data-end=\"1085\"\u003eDesigned with a high‑efficiency 220V condenser, this unit offers improved energy performance and greater capability to maintain consistent cellar temperatures in demanding environments, even with condenser air intake temperatures as high as 120 °F. The condenser can be located up to 100 feet from the evaporators, providing flexibility in installation layout for custom wine room designs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1087\" data-end=\"1520\"\u003eTemperature control is advanced and user‑friendly, featuring a KDT digital touch display that can be wall‑mounted up to 50 feet away and includes \u003cstrong data-start=\"1233\" data-end=\"1263\"\u003eAdvanced System Protection\u003c\/strong\u003e with audible and visual alerts. A liquid‑temperature bottle probe ensures accurate monitoring of your wine’s internal temperature, giving a more precise reflection of storage conditions than ambient air measurements. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1522\" data-end=\"1815\"\u003eIdeal for modern wine cellars, glass wine walls, and environments where both performance and aesthetics matter, this Platinum Split Twin system delivers powerful cooling with minimal noise and visible impact, making it suitable for luxury installations.\u003c\/p\u003e\n\u003ch3 data-start=\"641\" data-end=\"674\"\u003e\u003cstrong\u003eWho This Cooling System Is For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"676\" data-end=\"721\"\u003eThe Platinum Split Twin 220V is designed for:\u003c\/p\u003e\n\u003cul data-start=\"723\" data-end=\"1117\"\u003e\n\u003cli data-start=\"723\" data-end=\"794\"\u003eFully insulated wine cellars up to approximately \u003cstrong data-start=\"774\" data-end=\"794\"\u003e3,000 cubic feet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"795\" data-end=\"852\"\u003eModern glass wine walls (properly insulated and sealed)\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"903\"\u003eHigh-end residential or commercial installations\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"973\"\u003eProjects requiring remote condenser placement (up to 100 line feet)\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"1057\"\u003eInstallations in high ambient climates (up to 120°F condenser intake temperature)\u003c\/li\u003e\n\u003cli data-start=\"1058\" data-end=\"1117\"\u003eCellars where low interior mechanical noise is a priority\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1119\" data-end=\"1204\"\u003eThis system requires professional HVAC-R installation and proper cellar construction.\u003c\/p\u003e\n\u003ch3 data-start=\"1211\" data-end=\"1249\"\u003e\u003cstrong\u003eWhen This System Is Not Appropriate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1251\" data-end=\"1285\"\u003eDo \u003cstrong data-start=\"1254\" data-end=\"1261\"\u003enot\u003c\/strong\u003e install this system if:\u003c\/p\u003e\n\u003cul data-start=\"1287\" data-end=\"1598\"\u003e\n\u003cli data-start=\"1287\" data-end=\"1329\"\u003eThe cellar does not have a vapor barrier\u003c\/li\u003e\n\u003cli data-start=\"1330\" data-end=\"1373\"\u003eThe room is open to adjacent living space\u003c\/li\u003e\n\u003cli data-start=\"1374\" data-end=\"1421\"\u003eWall insulation is below recommended R-values\u003c\/li\u003e\n\u003cli data-start=\"1422\" data-end=\"1479\"\u003eThe cellar is under 1,750 cubic feet (may be oversized)\u003c\/li\u003e\n\u003cli data-start=\"1480\" data-end=\"1517\"\u003eYou are planning a DIY installation\u003c\/li\u003e\n\u003cli data-start=\"1518\" data-end=\"1598\"\u003eThe space includes excessive uninsulated stone, concrete, or non-thermal glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1600\" data-end=\"1702\"\u003eIf construction variables are unknown, a cooling load calculation should be completed before purchase.\u003c\/p\u003e\n\u003ch3 data-start=\"1709\" data-end=\"1761\"\u003e\u003cstrong\u003eWhat Is a Ducted Split Wine Cellar Cooling System?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1763\" data-end=\"1818\"\u003eA ducted split system separates the cooling components:\u003c\/p\u003e\n\u003cul data-start=\"1820\" data-end=\"2031\"\u003e\n\u003cli data-start=\"1820\" data-end=\"1909\"\u003e\n\u003cstrong data-start=\"1822\" data-end=\"1837\"\u003eEvaporators\u003c\/strong\u003e are installed inside or near the cellar and connected through ductwork.\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1981\"\u003eThe \u003cstrong data-start=\"1916\" data-end=\"1929\"\u003econdenser\u003c\/strong\u003e is installed remotely (indoor or outdoor location).\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"2031\"\u003eRefrigeration lines connect the two components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2033\" data-end=\"2170\"\u003eThis configuration reduces interior noise, increases installation flexibility, and allows the condenser to operate outside the wine room.\u003c\/p\u003e\n\u003cp data-start=\"2177\" data-end=\"2198\"\u003e\u003cstrong\u003eCooling Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2200\" data-end=\"2280\"\u003eCooling capacity varies based on condenser air intake temperature and fan speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2200\" data-end=\"2280\"\u003e\u003cstrong\u003eApproximate Cooling Output (Sensible \/ Total BTU)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Intake Temp\u003c\/th\u003e\n\u003cth\u003eLow\u003c\/th\u003e\n\u003cth\u003eMedium\u003c\/th\u003e\n\u003cth\u003eHigh\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003e7,256 – 8,208\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e7,131 – 8,061\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e6,843 – 7,845\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"2534\" data-end=\"2566\"\u003e\u003cstrong data-start=\"2534\" data-end=\"2566\"\u003eImportant Performance Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2568\" data-end=\"2878\"\u003e\n\u003cli data-start=\"2568\" data-end=\"2626\"\u003eHigher ambient temperatures reduce total cooling output.\u003c\/li\u003e\n\u003cli data-start=\"2627\" data-end=\"2669\"\u003eGlass walls increase sensible heat load.\u003c\/li\u003e\n\u003cli data-start=\"2670\" data-end=\"2745\"\u003eHigh fan speed increases BTU output but slightly increases airflow noise.\u003c\/li\u003e\n\u003cli data-start=\"2746\" data-end=\"2813\"\u003eInsulation and vapor barrier quality directly affect performance.\u003c\/li\u003e\n\u003cli data-start=\"2814\" data-end=\"2878\"\u003eUndersizing may cause continuous run time and compressor wear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2885\" data-end=\"2912\"\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2914\" data-end=\"2943\"\u003eTo achieve rated performance:\u003c\/p\u003e\n\u003cul data-start=\"2945\" data-end=\"3303\"\u003e\n\u003cli data-start=\"2945\" data-end=\"2975\"\u003eCellar must be fully sealed.\u003c\/li\u003e\n\u003cli data-start=\"2976\" data-end=\"3041\"\u003eVapor barrier must be installed on the warm side of insulation.\u003c\/li\u003e\n\u003cli data-start=\"3042\" data-end=\"3104\"\u003eRecommended insulation: minimum R-19 walls and R-30 ceiling.\u003c\/li\u003e\n\u003cli data-start=\"3105\" data-end=\"3150\"\u003eDedicated electrical circuits are required.\u003c\/li\u003e\n\u003cli data-start=\"3151\" data-end=\"3217\"\u003eInstallation must be performed by a qualified HVAC-R technician.\u003c\/li\u003e\n\u003cli data-start=\"3218\" data-end=\"3303\"\u003eRefrigerant charging and line set installation must follow manufacturer guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3305\" data-end=\"3359\"\u003eImproper installation voids the manufacturer warranty.\u003c\/p\u003e\n\u003ch2 data-start=\"3366\" data-end=\"3380\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"3382\" data-end=\"3415\"\u003e\n\u003cstrong\u003eTwin Evaporator Configuration\u003c\/strong\u003e\u003cbr\u003eDesigned to distribute airflow evenly in large custom cellars.\u003c\/li\u003e\n\u003cli data-start=\"3480\" data-end=\"3514\"\u003e\n\u003cstrong\u003e220V High-Efficiency Condenser\u003c\/strong\u003e\u003cbr\u003eImproves operational stability and efficiency in high ambient climates (up to 120°F).\n\u003cul\u003e\n\u003cli data-start=\"3602\" data-end=\"3642\"\u003eAdvanced Digital Touch Display (KDT)\n\u003cul\u003e\n\u003cli data-start=\"3643\" data-end=\"3682\"\u003eRemote installable up to 50 feet away\u003c\/li\u003e\n\u003cli data-start=\"3683\" data-end=\"3756\"\u003eBottle probe monitors liquid temperature for accurate wine preservation\u003c\/li\u003e\n\u003cli data-start=\"3757\" data-end=\"3792\"\u003eBuilt-in system protection alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3794\" data-end=\"3832\"\u003e\n\u003cstrong\u003eOptional 24V Thermostat Conversion\u003c\/strong\u003e\u003cbr\u003eAllows integration with third-party smart thermostats (thermostat not included).\u003cbr data-start=\"3913\" data-end=\"3916\"\u003eNote: Converting to 24V removes the bottle probe feature.\u003c\/li\u003e\n\u003cli data-start=\"3975\" data-end=\"3999\"\u003e\n\u003cstrong\u003eDucted Configuration\u003c\/strong\u003e\u003cbr\u003eAllows hidden installation and reduced interior mechanical noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4072\" data-end=\"4098\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4100\" data-end=\"4134\"\u003e\u003cstrong\u003eEvaporator (Twin Configuration)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCellar Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 cu. ft. (fully insulated \u0026amp; sealed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V (15-amp dedicated circuit required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning Amps\u003c\/td\u003e\n\u003ctd\u003ePrimary: 2.48A • Secondary: 2.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eApprox. 52–62 dBA (varies by fan speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Line\u003c\/td\u003e\n\u003ctd\u003e1\/2” ID clear plastic tubing (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostat\u003c\/td\u003e\n\u003ctd\u003eDigital display with liquid bottle probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Temp Delta\u003c\/td\u003e\n\u003ctd\u003eMaintains 55°F cellar with up to 120°F condenser intake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Limited (Parts \u0026amp; Labor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"3305\" data-end=\"3359\"\u003e\u003cstrong\u003eCondenser (220V High-Efficiency)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220V (15-amp dedicated circuit required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eLRA 20 • RLA 4.25 • FLA 4.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Set\u003c\/td\u003e\n\u003ctd\u003eLiquid: 3\/8” OD • Suction: 5\/8” OD (\u0026lt;50 ft) \/ 3\/4” OD (\u0026gt;50 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Line Length\u003c\/td\u003e\n\u003ctd\u003e100 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eUp to 120°F ambient temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Limited (Parts \u0026amp; Labor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-start=\"5142\" data-end=\"5176\"\u003e\u003cstrong\u003eWhat Sensible vs Total BTU Means\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5178\" data-end=\"5390\"\u003e\n\u003cli data-start=\"5178\" data-end=\"5228\"\u003e\n\u003cstrong data-start=\"5180\" data-end=\"5196\"\u003eSensible BTU\u003c\/strong\u003e measures temperature reduction.\u003c\/li\u003e\n\u003cli data-start=\"5229\" data-end=\"5292\"\u003e\n\u003cstrong data-start=\"5231\" data-end=\"5244\"\u003eTotal BTU\u003c\/strong\u003e includes both temperature and humidity removal.\u003c\/li\u003e\n\u003cli data-start=\"5293\" data-end=\"5335\"\u003eGlass wine walls increase sensible load.\u003c\/li\u003e\n\u003cli data-start=\"5336\" data-end=\"5390\"\u003eHigh humidity conditions increase total load demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5392\" data-end=\"5449\"\u003eUnderstanding this distinction helps prevent undersizing.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Platinum Split Twin Ducted:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Owner_Manual_bf504749-64bf-4012-a24a-c0c28884f0de.pdf?v=1646322715\" title=\"Owner Manual for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\" target=\"_blank\"\u003e Owner Manual for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/H.E._Owner_Manual_7cc4e909-9f52-4958-ac48-027d536b4472.pdf?v=1646322696\" title=\"H.E. Owner Manual for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\" target=\"_blank\"\u003eH.E. Owner Manual for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/220V_High-Efficiency_Product_Sheets_125fad33-b144-4f34-aeb9-1820d073c1bb.pdf?v=1646322286\" title=\"220V High Efficiency product Sheets for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\" target=\"_blank\"\u003e220V High Efficiency product Sheets for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/24V_Thermostat_Conversion_Kit.pdf?v=1646311024\" title=\"24V Thermostat Conversion Kit for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\" target=\"_blank\"\u003e24V Thermostat Conversion Kit for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Warranty_Checklist-Split_Systems_H.E.-051021.pdf?v=1646259053\" title=\"High Efficiency 220 Warranty Registration for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\" target=\"_blank\"\u003eHigh Efficiency 220 Warranty Registration for WhisperKOOL Platinum Split Twin Ducted Cooling System 220V High Efficiency\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePlatinum Split Twin vs Platinum 8000\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSplit Twin 220V\u003c\/th\u003e\n\u003cth\u003eSplit 8000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eTwin evaporators\u003c\/td\u003e\n\u003ctd\u003eSingle evaporator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdeal For\u003c\/td\u003e\n\u003ctd\u003eGlass wine walls\u003c\/td\u003e\n\u003ctd\u003eTraditional sealed cellars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Profile\u003c\/td\u003e\n\u003ctd\u003eVery low\u003c\/td\u003e\n\u003ctd\u003eLow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Flexibility\u003c\/td\u003e\n\u003ctd\u003eHigh\u003c\/td\u003e\n\u003ctd\u003eModerate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"5841\" data-end=\"5946\"\u003eIf your cellar includes large glass panels, the Twin configuration often distributes airflow more evenly.\u003c\/p\u003e\n\u003ch3 data-start=\"5953\" data-end=\"5975\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"5977\" data-end=\"6204\"\u003e\n\u003cli data-start=\"5977\" data-end=\"6040\"\u003eUV-C Light Technology (reduces mold growth within the system)\u003c\/li\u003e\n\u003cli data-start=\"6041\" data-end=\"6108\"\u003eExterior Protective Housing (for outdoor condenser installations)\u003c\/li\u003e\n\u003cli data-start=\"6109\" data-end=\"6172\"\u003eCondenser Coil Coating (recommended for coastal environments)\u003c\/li\u003e\n\u003cli data-start=\"6173\" data-end=\"6204\"\u003e24V Thermostat Conversion Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6206\" data-end=\"6283\"\u003eAccessories should be selected based on installation environment and climate.\u003c\/p\u003e\n\u003ch3 data-start=\"6290\" data-end=\"6326\"\u003e\u003cstrong\u003eProfessional Installation Required\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"6328\" data-end=\"6468\"\u003eThis system requires a qualified HVAC-R technician for installation.\u003cbr data-start=\"6396\" data-end=\"6399\"\u003eImproper installation or refrigerant handling will void the warranty.\u003c\/p\u003e\n\u003ch3 data-start=\"7537\" data-end=\"7564\"\u003e\u003cstrong\u003eWho Should Buy This Unit?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"7566\" data-end=\"7597\"\u003eThis system is best suited for:\u003c\/p\u003e\n\u003cul data-start=\"7599\" data-end=\"7839\"\u003e\n\u003cli data-start=\"7599\" data-end=\"7643\"\u003eCustom cellars between 2,500–3,000 cu. ft.\u003c\/li\u003e\n\u003cli data-start=\"7644\" data-end=\"7670\"\u003eGlass wine wall projects\u003c\/li\u003e\n\u003cli data-start=\"7671\" data-end=\"7698\"\u003eLuxury residential builds\u003c\/li\u003e\n\u003cli data-start=\"7699\" data-end=\"7725\"\u003eCommercial tasting rooms\u003c\/li\u003e\n\u003cli data-start=\"7726\" data-end=\"7790\"\u003eDesigners and contractors requiring remote condenser placement\u003c\/li\u003e\n\u003cli data-start=\"7791\" data-end=\"7839\"\u003eInstallations in warm or high-ambient climates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7841\" data-end=\"7960\"\u003eIf you are uncertain about sizing, our team can review your cellar dimensions and construction details before purchase.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583586591,"sku":"S-WKPS9000-220-FD","price":12639.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-platinum-split-twin-ducted-cooling-system-220v-high-efficiency-1187288151.jpg?v=1775520260","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-platinum-split-twin-220v-high-efficiency-ducted-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}