{"product_id":"whisperkool-quantum-ss9000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","title":"WhisperKOOL Quantum SS9000 220V High Efficiency Ducted Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"102\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Quantum SS9000 220V High Efficiency Ducted Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"132\" data-end=\"653\"\u003eThe WhisperKOOL Quantum SS9000 Ducted Split System 220V High Efficiency is a professional‑grade cooling solution engineered for medium‑to‑large wine cellars up to approximately \u003cstrong data-start=\"309\" data-end=\"329\"\u003e3,000 cubic feet\u003c\/strong\u003e when the space is properly insulated and sealed with a vapor barrier. Its fully ducted split‑system design separates the evaporator from the remote condenser, providing flexible installation options and quiet cellar operation by locating heat‑producing components outside the cellar. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"655\" data-end=\"1065\"\u003eDesigned with a high‑efficiency 220V condenser, this system delivers improved energy performance and the capability to maintain optimal wine storage conditions even in demanding environments with condenser intake air temperatures as high as 120 °F. Its components are built for durability, including corrosion‑resistant coils to withstand humidity and cellar outgassing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1067\" data-end=\"1502\"\u003eTemperature control is advanced and precise, with a \u003cstrong data-start=\"1119\" data-end=\"1148\"\u003eKDT digital touch display\u003c\/strong\u003e that can be mounted up to 50 feet away and features \u003cstrong data-start=\"1201\" data-end=\"1231\"\u003eAdvanced System Protection\u003c\/strong\u003e with alarm notifications for out‑of‑range conditions. A \u003cstrong data-start=\"1288\" data-end=\"1323\"\u003eliquid‑temperature bottle probe\u003c\/strong\u003e measures the actual wine temperature for more accurate readings than standard air sensors, helping maintain the ideal storage environment. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1504\" data-end=\"1883\"\u003eIdeal for custom residential or commercial cellars, this Quantum SS9000 system offers multiple ducting options, improved installation access through flare fittings and wiring, and quiet performance by keeping the condenser remote—an effective choice for wine collectors who demand reliable, consistent cooling performance in larger spaces.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQuick Technical Snapshot\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cellar Size\u003c\/td\u003e\n\u003ctd\u003e3,000 cu. ft. (fully insulated \u0026amp; sealed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eFully Ducted Split\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor\u003c\/td\u003e\n\u003ctd\u003e1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V (Evaporator) \/ 220V (Condenser)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Line Set\u003c\/td\u003e\n\u003ctd\u003e100 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range\u003c\/td\u003e\n\u003ctd\u003e-15°F to 120°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"2760\" data-end=\"2834\"\u003eThe 85°F rating is the industry standard reference for residential sizing.\u003c\/p\u003e\n\u003cp data-start=\"2836\" data-end=\"2901\"\u003eCooling capacity decreases as condenser intake temperature rises.\u003c\/p\u003e\n\u003ch3 data-start=\"2908\" data-end=\"2935\"\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2937\" data-end=\"2970\"\u003eThe 3,000 cu. ft. rating assumes:\u003c\/p\u003e\n\u003cul data-start=\"2972\" data-end=\"3160\"\u003e\n\u003cli data-start=\"2972\" data-end=\"3004\"\u003eMinimum R-19 insulated walls\u003c\/li\u003e\n\u003cli data-start=\"3005\" data-end=\"3043\"\u003eR-30 insulated ceiling recommended\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3100\"\u003eProper vapor barrier installed on warm side of walls\u003c\/li\u003e\n\u003cli data-start=\"3101\" data-end=\"3126\"\u003eAirtight construction\u003c\/li\u003e\n\u003cli data-start=\"3127\" data-end=\"3160\"\u003eMinimal direct glass exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3162\" data-end=\"3189\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3191\" data-end=\"3302\"\u003e\n\u003cli data-start=\"3191\" data-end=\"3246\"\u003eEvaporator: 120V (5-amp dedicated circuit required)\u003c\/li\u003e\n\u003cli data-start=\"3247\" data-end=\"3302\"\u003eCondenser: 220V (15-amp dedicated circuit required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3304\" data-end=\"3331\"\u003eBoth circuits are required.\u003c\/p\u003e\n\u003ch2 data-start=\"3338\" data-end=\"3373\"\u003e\u003cstrong\u003eDucting \u0026amp; Line Set Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"3375\" data-end=\"3506\"\u003e\n\u003cli data-start=\"3375\" data-end=\"3394\"\u003e14” supply duct\u003c\/li\u003e\n\u003cli data-start=\"3395\" data-end=\"3414\"\u003e14” return duct\u003c\/li\u003e\n\u003cli data-start=\"3415\" data-end=\"3444\"\u003eUp to 35 ft. per duct run\u003c\/li\u003e\n\u003cli data-start=\"3445\" data-end=\"3506\"\u003eMaximum 100 ft. line set between evaporator and condenser\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3508\" data-end=\"3526\"\u003e\u003cstrong\u003eLine Set Sizes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3527\" data-end=\"3632\"\u003e\n\u003cli data-start=\"3527\" data-end=\"3551\"\u003eLiquid line: 3\/8” OD\u003c\/li\u003e\n\u003cli data-start=\"3552\" data-end=\"3632\"\u003eSuction line:\n\u003cul data-start=\"3572\" data-end=\"3632\"\u003e\n\u003cli data-start=\"3572\" data-end=\"3599\"\u003e5\/8” (less than 50 ft.)\u003c\/li\u003e\n\u003cli data-start=\"3602\" data-end=\"3632\"\u003e3\/4” (greater than 50 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3634\" data-end=\"3699\"\u003eProfessional refrigerant charging and configuration are required.\u003c\/p\u003e\n\u003ch3 data-start=\"3706\" data-end=\"3728\"\u003e\u003cstrong\u003eSystem Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3730\" data-end=\"3753\"\u003e\u003cstrong\u003eSplit System Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3754\" data-end=\"3865\"\u003e\n\u003cli data-start=\"3754\" data-end=\"3791\"\u003eEvaporator installs inside cellar\u003c\/li\u003e\n\u003cli data-start=\"3792\" data-end=\"3865\"\u003eCondenser installs remotely (indoor or outdoor with optional housing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"3867\" data-end=\"3881\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEvaporator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"3883\" data-end=\"3946\"\u003e29.5” L x 30.9” W x 19.8” H\u003c\/li\u003e\n\u003cli data-start=\"3883\" data-end=\"3946\"\u003eWeight: 96 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3948\" data-end=\"4013\"\u003e\u003cstrong data-start=\"3948\" data-end=\"3961\"\u003eCondenser\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"3948\" data-end=\"4013\"\u003e31.18” L x 10.75” W x 21.18” H\u003c\/li\u003e\n\u003cli data-start=\"3948\" data-end=\"4013\"\u003eWeight: 64 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAirflow \u0026amp; Sound Performance\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eSound Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator\u003c\/td\u003e\n\u003ctd\u003e52 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser\u003c\/td\u003e\n\u003ctd\u003e48 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"4158\" data-end=\"4220\"\u003eFully ducted configuration reduces cellar noise significantly.\u003c\/p\u003e\n\u003cp data-start=\"4222\" data-end=\"4238\"\u003eAirflow (CFM):\u003c\/p\u003e\n\u003cul data-start=\"4239\" data-end=\"4282\"\u003e\n\u003cli data-start=\"4239\" data-end=\"4252\"\u003e590 (Low)\u003c\/li\u003e\n\u003cli data-start=\"4253\" data-end=\"4269\"\u003e650 (Medium)\u003c\/li\u003e\n\u003cli data-start=\"4270\" data-end=\"4282\"\u003e710 (High)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Quantum SS9000 Ducted Split:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"220V High Efficiency (H.E.) Condenser Owner's Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Quantum_HE_OM_022124.pdf?v=1752171592\" target=\"_blank\"\u003e220V High Efficiency (H.E.) Condenser Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"220V (Copeland) Condenser Owner's Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Quantum_Copeland_OM_010625.pdf?v=1752171726\" target=\"_blank\"\u003e220V (Copeland) Condenser Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Quick Start Guide\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_QuickStart_Guide_Quantum_9000-12000_1.pdf?v=1752171849\" target=\"_blank\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Warranty Checklist\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Split-System-Warranty-Checklist_6_11_24.pdf?v=1752171915\" target=\"_blank\"\u003eWarranty Checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"220V H.E Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Quantum_ProductSheet_11_11.pdf?v=1752172066\" target=\"_blank\"\u003e220V H.E Product Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"220V Copeland Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Ducted_Split-Quantum_ProductSheet_020622.pdf?v=1752172065\" target=\"_blank\"\u003e220V Copeland Product Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Charge Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Quantum_9000_-_12000_-_Charge_Chart.pdf?v=1752172220\" target=\"_blank\"\u003eCharge Chart\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Maintenance Checklist\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Maintenance_Checklist_Quantum_H.E._220V.pdf?v=1752172393\" target=\"_blank\"\u003eMaintenance Checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4289\" data-end=\"4310\"\u003e\u003cstrong\u003eHumidity Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4312\" data-end=\"4424\"\u003eThe Quantum SS9000 is designed to maintain relative humidity between \u003cstrong data-start=\"4381\" data-end=\"4391\"\u003e50–70%\u003c\/strong\u003e in properly sealed environments.\u003c\/p\u003e\n\u003cp data-start=\"4426\" data-end=\"4527\"\u003eIn dry climates or high-ventilation conditions, a supplemental humidification system may be required.\u003c\/p\u003e\n\u003ch3 data-start=\"4811\" data-end=\"4836\"\u003e\u003cstrong\u003eAmbient Operating Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4838\" data-end=\"4885\"\u003eThe 220V high-efficiency condenser operates in:\u003c\/p\u003e\n\u003cul data-start=\"4887\" data-end=\"4971\"\u003e\n\u003cli data-start=\"4887\" data-end=\"4929\"\u003eLow ambient temperatures down to -15°F\u003c\/li\u003e\n\u003cli data-start=\"4930\" data-end=\"4971\"\u003eHigh ambient temperatures up to 120°F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4973\" data-end=\"5041\"\u003eExterior condenser housing is recommended for outdoor installations.\u003c\/p\u003e\n\u003ch3 data-start=\"5048\" data-end=\"5058\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"5062\" data-end=\"5103\"\u003e2-Year Limited Warranty (Parts \u0026amp; Labor)\u003c\/li\u003e\n\u003cli data-start=\"5106\" data-end=\"5155\"\u003eAdditional 1-Year Grace Period for Installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5157\" data-end=\"5208\"\u003eWarranty requires professional HVAC-R installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantum SS9000 vs Quantum SS12000\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSS9000\u003c\/th\u003e\n\u003cth\u003eSS12000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cellar Size\u003c\/td\u003e\n\u003ctd\u003e3,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e4,000 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor\u003c\/td\u003e\n\u003ctd\u003e1 HP\u003c\/td\u003e\n\u003ctd\u003e1.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Application\u003c\/td\u003e\n\u003ctd\u003eLarge residential\u003c\/td\u003e\n\u003ctd\u003eOversized or commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-start=\"6894\" data-end=\"6916\"\u003e\u003cstrong\u003eFinal Recommendation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"6918\" data-end=\"7099\"\u003eThe WhisperKOOL Quantum SS9000 is a professional ducted split cooling solution for large, properly constructed wine cellars requiring quiet performance and installation flexibility.\u003c\/p\u003e\n\u003cp data-start=\"7101\" data-end=\"7126\"\u003eBefore purchase, confirm:\u003c\/p\u003e\n\u003cul data-start=\"7128\" data-end=\"7260\"\u003e\n\u003cli data-start=\"7128\" data-end=\"7145\"\u003eCellar volume\u003c\/li\u003e\n\u003cli data-start=\"7146\" data-end=\"7168\"\u003eInsulation quality\u003c\/li\u003e\n\u003cli data-start=\"7169\" data-end=\"7199\"\u003eVapor barrier installation\u003c\/li\u003e\n\u003cli data-start=\"7200\" data-end=\"7227\"\u003eElectrical availability\u003c\/li\u003e\n\u003cli data-start=\"7228\" data-end=\"7260\"\u003eLine set routing feasibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7262\" data-end=\"7381\"\u003eIf you need assistance verifying sizing, our cooling specialists can review your cellar specifications before ordering.\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583553823,"sku":"S-WKQS9000-220-FD","price":10605.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-quantum-ss9000-ducted-split-system-220v-high-efficiency-1187288137.jpg?v=1775520260","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-quantum-ss9000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}