{"product_id":"whisperkool-quantum-twin-18000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","title":"WhisperKOOL Quantum Twin 18000 220V High Efficiency Ducted Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"106\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Quantum Twin 18000 220V High Efficiency Ducted Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"136\" data-end=\"612\"\u003eThe WhisperKOOL Quantum Twin 18000 Ducted Split System 220V High Efficiency is a commercial‑grade cooling solution engineered to handle large wine cellars up to approximately \u003cstrong data-start=\"311\" data-end=\"331\"\u003e5,000 cubic feet\u003c\/strong\u003e when fully insulated and sealed with a proper vapor barrier. Its fully ducted split‑system design separates the evaporators and condenser, keeping noise and heat outside the cellar while delivering powerful and reliable cooling performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"614\" data-end=\"1010\"\u003eDesigned for quiet operation and high heat‑load environments—including cellars with extensive glass, lighting, or warmer climates—the Quantum Twin 18000 provides exceptional cooling capacity with flexibility for long duct runs and extended line sets. Installation requires a licensed HVAC‑R technician to ensure optimal performance and warranty compliance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1012\" data-end=\"1455\"\u003eThe system’s advanced control package includes a digital touch display with \u003cstrong data-start=\"1088\" data-end=\"1118\"\u003eAdvanced System Protection\u003c\/strong\u003e and a liquid‑temperature bottle probe, which measures the actual wine temperature for more precise control than standard air sensors. With professional features and robust capacity, this system is ideal for collectors and commercial spaces demanding high‑capacity, consistent wine cellar cooling. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1457\" data-end=\"1752\"\u003eWhether cooling a large residential cellar or upscale commercial wine room, the WhisperKOOL Quantum Twin 18000 delivers performance, flexibility, and quiet operation—helping ensure your wine collection is maintained within its optimal storage environment.\u003c\/p\u003e\n\u003cp data-end=\"906\" data-start=\"836\"\u003eThis 220V high-efficiency system is engineered for projects requiring:\u003c\/p\u003e\n\u003cul data-end=\"1118\" data-start=\"908\"\u003e\n\u003cli data-end=\"961\" data-start=\"908\"\u003eQuiet cellar operation (remote equipment placement)\u003c\/li\u003e\n\u003cli data-end=\"1021\" data-start=\"962\"\u003eHigh heat-load tolerance (glass, lighting, warm climates)\u003c\/li\u003e\n\u003cli data-end=\"1061\" data-start=\"1022\"\u003eLong duct runs and extended line sets\u003c\/li\u003e\n\u003cli data-end=\"1118\" data-start=\"1062\"\u003eExtreme ambient temperature operation (-20°F to 120°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1165\" data-start=\"1120\"\u003eProfessional HVAC-R installation is required.\u003c\/p\u003e\n\u003ch3 data-end=\"1223\" data-start=\"1172\"\u003e\u003cstrong\u003eIs This the Right Cooling System for Your Cellar?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1266\" data-start=\"1225\"\u003eThe Quantum Twin 18000 is appropriate if:\u003c\/p\u003e\n\u003cul data-end=\"1654\" data-start=\"1268\"\u003e\n\u003cli data-end=\"1316\" data-start=\"1268\"\u003eYour cellar is between \u003cstrong data-end=\"1316\" data-start=\"1293\"\u003e3,500–5,000 cu. ft.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1408\" data-start=\"1317\"\u003eWalls and ceiling meet minimum insulation standards (R19 walls \/ R30 ceiling recommended)\u003c\/li\u003e\n\u003cli data-end=\"1456\" data-start=\"1409\"\u003eA continuous 6-mil vapor barrier is installed\u003c\/li\u003e\n\u003cli data-end=\"1517\" data-start=\"1457\"\u003eYou require fully ducted installation to conceal equipment\u003c\/li\u003e\n\u003cli data-end=\"1583\" data-start=\"1518\"\u003eThe condenser may be installed remotely (up to 100 ft line set)\u003c\/li\u003e\n\u003cli data-end=\"1654\" data-start=\"1584\"\u003eYou operate in climates with significant seasonal temperature swings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1698\" data-start=\"1661\"\u003e\u003cstrong\u003eWhen This System Is NOT Recommended\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1736\" data-start=\"1700\"\u003eThis system may be inappropriate if:\u003c\/p\u003e\n\u003cul data-end=\"2029\" data-start=\"1738\"\u003e\n\u003cli data-end=\"1774\" data-start=\"1738\"\u003eYour cellar is under 3,000 cu. ft.\u003c\/li\u003e\n\u003cli data-end=\"1818\" data-start=\"1775\"\u003eInsulation or vapor barrier is incomplete\u003c\/li\u003e\n\u003cli data-end=\"1893\" data-start=\"1819\"\u003eThe room contains excessive unconditioned glass without load calculation\u003c\/li\u003e\n\u003cli data-end=\"1960\" data-start=\"1894\"\u003eElectrical infrastructure cannot support dual dedicated circuits\u003c\/li\u003e\n\u003cli data-end=\"2029\" data-start=\"1961\"\u003eInstallation will not be performed by a licensed HVAC-R technician\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2078\" data-start=\"2031\"\u003eAn undersized or improperly installed unit may:\u003c\/p\u003e\n\u003cul data-end=\"2181\" data-start=\"2080\"\u003e\n\u003cli data-end=\"2103\" data-start=\"2080\"\u003eFail to maintain 55°F\u003c\/li\u003e\n\u003cli data-end=\"2122\" data-start=\"2104\"\u003eRun continuously\u003c\/li\u003e\n\u003cli data-end=\"2152\" data-start=\"2123\"\u003eShorten compressor lifespan\u003c\/li\u003e\n\u003cli data-end=\"2181\" data-start=\"2153\"\u003eVoid manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2250\" data-start=\"2183\"\u003eHeat load calculations are strongly recommended prior to selection.\u003c\/p\u003e\n\u003cp data-end=\"2289\" data-start=\"2257\"\u003e\u003cstrong\u003eCooling Performance \u0026amp; Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"2351\" data-start=\"2291\"\u003eCooling output varies based on condenser intake temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2384\" data-start=\"2353\"\u003e\u003cstrong\u003eRated Capacity (Per System)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"2415\" data-start=\"2386\"\u003e\u003cstrong data-end=\"2415\" data-start=\"2386\"\u003eAt 60°F condenser intake:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2466\" data-start=\"2416\"\u003e\n\u003cli data-end=\"2442\" data-start=\"2416\"\u003eSensible: 15,513 BTU\/h\u003c\/li\u003e\n\u003cli data-end=\"2466\" data-start=\"2443\"\u003eTotal: 18,250 BTU\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2497\" data-start=\"2468\"\u003e\u003cstrong data-end=\"2497\" data-start=\"2468\"\u003eAt 75°F condenser intake:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2548\" data-start=\"2498\"\u003e\n\u003cli data-end=\"2524\" data-start=\"2498\"\u003eSensible: 14,582 BTU\/h\u003c\/li\u003e\n\u003cli data-end=\"2548\" data-start=\"2525\"\u003eTotal: 17,155 BTU\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2579\" data-start=\"2550\"\u003e\u003cstrong data-end=\"2579\" data-start=\"2550\"\u003eAt 85°F condenser intake:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2630\" data-start=\"2580\"\u003e\n\u003cli data-end=\"2606\" data-start=\"2580\"\u003eSensible: 13,806 BTU\/h\u003c\/li\u003e\n\u003cli data-end=\"2630\" data-start=\"2607\"\u003eTotal: 16,243 BTU\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-end=\"2798\" data-start=\"2632\"\u003e\n\u003cp data-end=\"2798\" data-start=\"2634\"\u003eBTU output decreases as condenser intake temperature increases. Always size your system based on the highest expected ambient temperature at the condenser location.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3 data-end=\"2824\" data-start=\"2805\"\u003e\u003cstrong\u003eOperational Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3006\" data-start=\"2826\"\u003e\n\u003cli data-end=\"2870\" data-start=\"2826\"\u003eMaintains cellar temperatures down to 55°F\u003c\/li\u003e\n\u003cli data-end=\"2928\" data-start=\"2871\"\u003eOperates with condenser intake temperatures up to 120°F\u003c\/li\u003e\n\u003cli data-end=\"3006\" data-start=\"2929\"\u003eFunctions in ambient conditions as low as -20°F (with proper configuration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3060\" data-start=\"3013\"\u003e\u003cstrong\u003eElectrical Requirements (Dual-Voltage System)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"3108\" data-start=\"3062\"\u003e⚠ This system requires two dedicated circuits:\u003c\/p\u003e\n\u003cul data-end=\"3230\" data-start=\"3110\"\u003e\n\u003cli data-end=\"3170\" data-start=\"3110\"\u003e\n\u003cstrong data-end=\"3127\" data-start=\"3112\"\u003eEvaporator:\u003c\/strong\u003e 120V (15-amp dedicated circuit required)\u003c\/li\u003e\n\u003cli data-end=\"3230\" data-start=\"3171\"\u003e\n\u003cstrong data-end=\"3187\" data-start=\"3173\"\u003eCondenser:\u003c\/strong\u003e 220V (15-amp dedicated circuit required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3281\" data-start=\"3232\"\u003eImproper electrical configuration voids warranty.\u003c\/p\u003e\n\u003ch3 data-end=\"3325\" data-start=\"3288\"\u003e\u003cstrong\u003eInstallation \u0026amp; Ducting Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3542\" data-start=\"3327\"\u003e\n\u003cli data-end=\"3355\" data-start=\"3327\"\u003eFully ducted configuration\u003c\/li\u003e\n\u003cli data-end=\"3373\" data-start=\"3356\"\u003e14” Supply duct\u003c\/li\u003e\n\u003cli data-end=\"3391\" data-start=\"3374\"\u003e14” Return duct\u003c\/li\u003e\n\u003cli data-end=\"3418\" data-start=\"3392\"\u003eUp to 35 ft per duct run\u003c\/li\u003e\n\u003cli data-end=\"3477\" data-start=\"3419\"\u003eMaximum 100 ft line set between evaporator and condenser\u003c\/li\u003e\n\u003cli data-end=\"3501\" data-start=\"3478\"\u003eLine set not included\u003c\/li\u003e\n\u003cli data-end=\"3542\" data-start=\"3502\"\u003eLicensed HVAC-R installation mandatory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3625\" data-start=\"3544\"\u003eImproper duct sizing or excessive static pressure will reduce cooling efficiency.\u003c\/p\u003e\n\u003ch2 data-end=\"3678\" data-start=\"3632\"\u003e\u003cstrong\u003eSystem Components \u0026amp; Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"3815\" data-start=\"3680\"\u003e\u003cstrong data-end=\"3700\" data-start=\"3680\"\u003eCellar Capacity:\u003c\/strong\u003e Up to 5,000 cu. ft.*\u003c\/p\u003e\n\u003cp data-end=\"3815\" data-start=\"3680\"\u003e\u003cstrong data-end=\"3740\" data-start=\"3724\"\u003eRefrigerant:\u003c\/strong\u003e R-134a\u003c\/p\u003e\n\u003cp data-end=\"3815\" data-start=\"3680\"\u003e\u003cstrong data-end=\"3765\" data-start=\"3750\"\u003eCompressor:\u003c\/strong\u003e 2 HP commercial-grade\u003c\/p\u003e\n\u003cp data-end=\"3815\" data-start=\"3680\"\u003e\u003cstrong data-end=\"3815\" data-start=\"3790\"\u003eCFM (Per Evaporator):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3873\" data-start=\"3816\"\u003e\n\u003cli data-end=\"3833\" data-start=\"3816\"\u003e590 (low speed)\u003c\/li\u003e\n\u003cli data-end=\"3854\" data-start=\"3834\"\u003e650 (medium speed)\u003c\/li\u003e\n\u003cli data-end=\"3873\" data-start=\"3855\"\u003e710 (high speed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3891\" data-start=\"3875\"\u003e\u003cstrong data-end=\"3891\" data-start=\"3875\"\u003eNoise Level:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3934\" data-start=\"3892\"\u003e\n\u003cli data-end=\"3913\" data-start=\"3892\"\u003e58 dBA (Evaporator)\u003c\/li\u003e\n\u003cli data-end=\"3934\" data-start=\"3914\"\u003e58 dBA (Condenser)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3951\" data-start=\"3936\"\u003e\u003cstrong data-end=\"3951\" data-start=\"3936\"\u003eDimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4035\" data-start=\"3952\"\u003e\n\u003cli data-end=\"3992\" data-start=\"3952\"\u003eEvaporator: 29.5”L x 30.9”W x 19.8”H\u003c\/li\u003e\n\u003cli data-end=\"4035\" data-start=\"3993\"\u003eCondenser: 31.18”L x 10.75”W x 23.25”H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4048\" data-start=\"4037\"\u003e\u003cstrong data-end=\"4048\" data-start=\"4037\"\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4094\" data-start=\"4049\"\u003e\n\u003cli data-end=\"4071\" data-start=\"4049\"\u003eEvaporator: 96 lbs\u003c\/li\u003e\n\u003cli data-end=\"4094\" data-start=\"4072\"\u003eCondenser: 116 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4105\" data-start=\"4096\"\u003e\u003cstrong data-end=\"4105\" data-start=\"4096\"\u003eAmps:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4181\" data-start=\"4106\"\u003e\n\u003cli data-end=\"4140\" data-start=\"4106\"\u003eEvaporator: 9.2 (Running Amps)\u003c\/li\u003e\n\u003cli data-end=\"4181\" data-start=\"4141\"\u003eCondenser: LRA 37, RLA 6.5, FLA 7.56\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4196\" data-start=\"4183\"\u003e\u003cstrong data-end=\"4196\" data-start=\"4183\"\u003eLine Set:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4283\" data-start=\"4197\"\u003e\n\u003cli data-end=\"4216\" data-start=\"4197\"\u003eLiquid: 3\/8” OD\u003c\/li\u003e\n\u003cli data-end=\"4255\" data-start=\"4217\"\u003eSuction: 5\/8” OD (less than 50 ft)\u003c\/li\u003e\n\u003cli data-end=\"4283\" data-start=\"4256\"\u003e3\/4” (greater than 50 ft)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4315\" data-start=\"4285\"\u003e\u003cstrong data-end=\"4300\" data-start=\"4285\"\u003eDrain Line:\u003c\/strong\u003e 3\/4” ID CPVC\u003c\/p\u003e\n\u003cp data-end=\"4342\" data-start=\"4317\"\u003e\u003cstrong data-end=\"4342\" data-start=\"4317\"\u003eThermostat \u0026amp; Control:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4447\" data-start=\"4343\"\u003e\n\u003cli data-end=\"4389\" data-start=\"4343\"\u003eAdvanced digital touch display (50 ft cable)\u003c\/li\u003e\n\u003cli data-end=\"4447\" data-start=\"4390\"\u003eLiquid temperature measuring bottle probe (50 ft cable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4462\" data-start=\"4449\"\u003e\u003cstrong data-end=\"4462\" data-start=\"4449\"\u003eWarranty:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4560\" data-start=\"4463\"\u003e\n\u003cli data-end=\"4488\" data-start=\"4463\"\u003e2-Year Limited Warranty\u003c\/li\u003e\n\u003cli data-end=\"4560\" data-start=\"4489\"\u003eUp to 1-Year Additional Grace Period for Installation (parts \u0026amp; labor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4617\" data-start=\"4562\"\u003e*Capacity assumes proper insulation and vapor barrier.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Quantum Twin 18000 Ducted Split:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Twin_Quantum_HE_OM_022124.pdf?v=1752176039\" title=\"Owner's Manual\" rel=\"noopener\" target=\"_blank\"\u003eOwner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_QuickStart_Guide_Quantum_Twin_18000-24000.pdf?v=1752176031\" title=\"Quick Start Guide\" rel=\"noopener\" target=\"_blank\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Split-System-Warranty-Checklist_6_11_24_1.pdf?v=1752176421\" title=\"Warranty Checklist\" rel=\"noopener\" target=\"_blank\"\u003eWarranty Checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"220V H.E Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Quantum_ProductSheet_11_11.pdf?v=1752172066\" target=\"_blank\"\u003e220V H.E Product Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"220V Copeland Product Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Ducted_Split-Quantum_ProductSheet_020622.pdf?v=1752172065\" target=\"_blank\"\u003e220V Copeland Product Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Maintenance Checklist\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Maintenance_Checklist_Quantum_H.E._220V.pdf?v=1752172393\" target=\"_blank\"\u003eMaintenance Checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Quantum_Twin_18000-24000_-_Charge_Chart.pdf?v=1752176660\" title=\"Charge Chart\" rel=\"noopener\" target=\"_blank\"\u003eCharge Chart\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4657\" data-start=\"4624\"\u003e\u003cstrong\u003eOptional Upgrades \u0026amp; Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"4700\" data-start=\"4659\"\u003e\u003cstrong\u003eExterior Condenser Protective Housing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"4761\" data-start=\"4701\"\u003eRequired for outdoor installations.\u003cbr\u003eProtects condenser from:\u003c\/p\u003e\n\u003cul data-end=\"4795\" data-start=\"4762\"\u003e\n\u003cli data-end=\"4768\" data-start=\"4762\"\u003eRain\u003c\/li\u003e\n\u003cli data-end=\"4775\" data-start=\"4769\"\u003eSnow\u003c\/li\u003e\n\u003cli data-end=\"4786\" data-start=\"4776\"\u003eSalt air\u003c\/li\u003e\n\u003cli data-end=\"4795\" data-start=\"4787\"\u003eDebris\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4835\" data-start=\"4802\"\u003e\u003cstrong\u003e24V Thermostat Conversion Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"4880\" data-start=\"4836\"\u003eAllows use of third-party smart thermostats.\u003c\/p\u003e\n\u003cp data-end=\"4892\" data-start=\"4882\"\u003eImportant:\u003c\/p\u003e\n\u003cul data-end=\"5035\" data-start=\"4893\"\u003e\n\u003cli data-end=\"4936\" data-start=\"4893\"\u003eRemoves standard WhisperKOOL bottle probe\u003c\/li\u003e\n\u003cli data-end=\"4968\" data-start=\"4937\"\u003eSmart thermostat not included\u003c\/li\u003e\n\u003cli data-end=\"5035\" data-start=\"4969\"\u003eWhisperKOOL does not provide support for third-party thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"5066\" data-start=\"5042\"\u003e\u003cstrong\u003eUV-C Lighting System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"5133\" data-start=\"5067\"\u003eHelps reduce microbial buildup inside the evaporator coil housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"5182\" data-start=\"5140\"\u003e\u003cstrong\u003eQuantum Twin 18000 vs Quantum Twin 24000\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"5208\" data-start=\"5184\"\u003eChoose the \u003cstrong data-end=\"5204\" data-start=\"5195\"\u003e18000\u003c\/strong\u003e if:\u003c\/p\u003e\n\u003cul data-end=\"5297\" data-start=\"5209\"\u003e\n\u003cli data-end=\"5240\" data-start=\"5209\"\u003eCellar is under 5,000 cu. ft.\u003c\/li\u003e\n\u003cli data-end=\"5261\" data-start=\"5241\"\u003eModerate heat load\u003c\/li\u003e\n\u003cli data-end=\"5297\" data-start=\"5262\"\u003ePrimarily residential application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"5323\" data-start=\"5299\"\u003eChoose the \u003cstrong data-end=\"5319\" data-start=\"5310\"\u003e24000\u003c\/strong\u003e if:\u003c\/p\u003e\n\u003cul data-end=\"5440\" data-start=\"5324\"\u003e\n\u003cli data-end=\"5354\" data-start=\"5324\"\u003eCellar exceeds 5,000 cu. ft.\u003c\/li\u003e\n\u003cli data-end=\"5377\" data-start=\"5355\"\u003eHeavy glass exposure\u003c\/li\u003e\n\u003cli data-end=\"5402\" data-start=\"5378\"\u003eCommercial environment\u003c\/li\u003e\n\u003cli data-end=\"5440\" data-start=\"5403\"\u003eHigh ambient condenser temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"6945\" data-start=\"6920\"\u003e\u003cstrong\u003eFinal Technical Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"7157\" data-start=\"6947\"\u003eThe WhisperKOOL Quantum Twin 18000 is a high-capacity, fully ducted, dual-voltage split cooling system engineered for large wine cellars requiring quiet operation, high reliability, and stable aging conditions.\u003c\/p\u003e\n\u003cp data-end=\"7286\" data-start=\"7159\"\u003eCorrect sizing, insulation, vapor barrier installation, and professional HVAC configuration are critical to system performance.\u003c\/p\u003e\n\u003cp data-end=\"7376\" data-start=\"7288\"\u003eFor projects approaching or exceeding 5,000 cubic feet, evaluate the Quantum Twin 24000.\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583488287,"sku":"S-WKQS18000-220-FD","price":14669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-quantum-twin-18000-ducted-split-system-220v-high-efficiency-1187288115.jpg?v=1775520258","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-quantum-twin-18000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}