{"product_id":"whisperkool-quantum-twin-24000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","title":"WhisperKOOL Quantum Twin 24000 220V High Efficiency Ducted Wine Cellar Cooling System","description":"\u003ch2 data-start=\"0\" data-end=\"106\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhisperKOOL Quantum Twin 24000 220V High Efficiency Ducted Wine Cellar Cooling System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"136\" data-end=\"786\"\u003eThe WhisperKOOL Quantum Twin 24000 Ducted Split System 220V High Efficiency is a robust commercial‑grade cooling solution engineered for \u003cstrong data-start=\"273\" data-end=\"301\"\u003eextra‑large wine cellars\u003c\/strong\u003e up to approximately \u003cstrong data-start=\"322\" data-end=\"342\"\u003e7,000 cubic feet\u003c\/strong\u003e when constructed with proper insulation and a sealed vapor barrier. Its fully ducted split‑system design separates the evaporators and condenser, allowing quiet operation inside the cellar while locating heat‑producing components externally or in an adjacent equipment area.\u003c\/p\u003e\n\u003cp data-start=\"788\" data-end=\"1165\"\u003eDesigned for stability and performance in demanding environments, the system uses a high‑efficiency 220V condenser that maintains consistent temperature control even when condenser intake air temperatures reach up to \u003cstrong data-start=\"1005\" data-end=\"1015\"\u003e120 °F\u003c\/strong\u003e. Its corrosion‑resistant coils are specifically engineered to withstand typical wine cellar environments, including humidity and cellar outgassing.\u003c\/p\u003e\n\u003cp data-start=\"1167\" data-end=\"1578\"\u003eAdvanced digital controls include a \u003cstrong data-start=\"1203\" data-end=\"1224\"\u003eKDT touch display\u003c\/strong\u003e with \u003cstrong data-start=\"1230\" data-end=\"1260\"\u003eAdvanced System Protection\u003c\/strong\u003e and alert notifications for critical parameters, as well as a \u003cstrong data-start=\"1323\" data-end=\"1358\"\u003eliquid‑temperature bottle probe\u003c\/strong\u003e that measures the actual liquid wine temperature for more precise preservation conditions than standard air sensors. Multiple evaporators allow flexible ducting options to deliver conditioned air exactly where needed.\u003c\/p\u003e\n\u003cp data-start=\"1580\" data-end=\"1821\"\u003eWhether cooling a large residential collection, a hospitality space, or a high‑capacity commercial display room, the WhisperKOOL Quantum Twin 24000 provides dependable performance, flexible installation, and precise temperature management.\u003c\/p\u003e\n\u003ch3 data-start=\"1123\" data-end=\"1147\"\u003e\u003cstrong\u003eQuick Decision Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1149\" data-end=\"1264\"\u003e\n\u003cstrong data-start=\"1149\" data-end=\"1162\"\u003eBest For: \u003c\/strong\u003eLarge wine rooms 5,500–7,500 cu. ft., commercial cellars, glass wine walls, high ambient climates\u003c\/li\u003e\n\u003cli data-start=\"1266\" data-end=\"1379\"\u003e\n\u003cstrong data-start=\"1266\" data-end=\"1278\"\u003eNot For: \u003c\/strong\u003eCellars under 4,000 cu. ft., through-wall installs, projects without vapor barrier or 220V power\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1381\" data-end=\"1397\"\u003eSystem Type:\u003c\/strong\u003e Fully ducted split system\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1426\" data-end=\"1446\"\u003eMax Cellar Size:\u003c\/strong\u003e 7,500 cu. ft. (proper insulation required)\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1492\" data-end=\"1504\"\u003eVoltage:\u003c\/strong\u003e 120V evaporator \/ 220V condenser\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1540\" data-end=\"1555\"\u003eCompressor:\u003c\/strong\u003e 3 HP\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1563\" data-end=\"1598\"\u003eCooling Capacity (85°F intake):\u003c\/strong\u003e 21,519 BTU (Sensible) \/ 25,317 BTU (Total)\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1644\" data-end=\"1661\"\u003eInstallation:\u003c\/strong\u003e Licensed HVAC-R technician required\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1700\" data-end=\"1722\"\u003eLine Set Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1729\" data-end=\"1806\"\u003eHeat load calculations are strongly recommended before selecting this system.\u003c\/p\u003e\n\u003ch3 data-start=\"1813\" data-end=\"1846\"\u003e\u003cstrong\u003eWho This System Is Designed For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1848\" data-end=\"1891\"\u003eThe Quantum Twin 24000 is appropriate when:\u003c\/p\u003e\n\u003cul data-start=\"1893\" data-end=\"2216\"\u003e\n\u003cli data-start=\"1893\" data-end=\"1933\"\u003eYour cellar exceeds 5,500 cubic feet\u003c\/li\u003e\n\u003cli data-start=\"1934\" data-end=\"1973\"\u003eYou have significant glass exposure\u003c\/li\u003e\n\u003cli data-start=\"1974\" data-end=\"2022\"\u003eYou need ducted, hidden mechanical equipment\u003c\/li\u003e\n\u003cli data-start=\"2023\" data-end=\"2082\"\u003eThe condenser must be installed remotely (up to 100 ft)\u003c\/li\u003e\n\u003cli data-start=\"2083\" data-end=\"2133\"\u003eThe project is commercial or hospitality-grade\u003c\/li\u003e\n\u003cli data-start=\"2134\" data-end=\"2216\"\u003eThe installation environment reaches up to 120°F condenser intake temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2218\" data-end=\"2248\"\u003eThis unit is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"2250\" data-end=\"2388\"\u003e\n\u003cli data-start=\"2250\" data-end=\"2277\"\u003eLarge luxury residences\u003c\/li\u003e\n\u003cli data-start=\"2278\" data-end=\"2320\"\u003eRestaurants and hospitality wine rooms\u003c\/li\u003e\n\u003cli data-start=\"2321\" data-end=\"2359\"\u003eCommercial wine storage facilities\u003c\/li\u003e\n\u003cli data-start=\"2360\" data-end=\"2388\"\u003eEstate-scale wine vaults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2395\" data-end=\"2432\"\u003e\u003cstrong\u003eWhen This System Is NOT Appropriate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2434\" data-end=\"2469\"\u003eThis system may not be suitable if:\u003c\/p\u003e\n\u003cul data-start=\"2471\" data-end=\"2751\"\u003e\n\u003cli data-start=\"2471\" data-end=\"2509\"\u003eYour cellar is under 4,000 cu. ft.\u003c\/li\u003e\n\u003cli data-start=\"2510\" data-end=\"2598\"\u003eInsulation is below recommended R-values (R-19 walls \/ R-30 ceiling minimum typical)\u003c\/li\u003e\n\u003cli data-start=\"2599\" data-end=\"2649\"\u003eNo properly installed vapor barrier is present\u003c\/li\u003e\n\u003cli data-start=\"2650\" data-end=\"2696\"\u003eYou cannot supply a 220V dedicated circuit\u003c\/li\u003e\n\u003cli data-start=\"2697\" data-end=\"2751\"\u003eYou need a self-contained or through-wall solution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2753\" data-end=\"2890\"\u003eAn oversized unit in a small cellar can short cycle. An undersized unit in a large cellar will run continuously and may fail prematurely.\u003c\/p\u003e\n\u003ch3 data-start=\"2897\" data-end=\"2941\"\u003e\u003cstrong\u003eCooling Performance by Ambient Temperature\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2943\" data-end=\"3013\"\u003eCooling capacity varies depending on condenser air intake temperature.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Intake Temp\u003c\/th\u003e\n\u003cth\u003eSensible BTU\u003c\/th\u003e\n\u003cth\u003eTotal BTU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F\u003c\/td\u003e\n\u003ctd\u003e22,893\u003c\/td\u003e\n\u003ctd\u003e26,933\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e21,977\u003c\/td\u003e\n\u003ctd\u003e25,856\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e21,519\u003c\/td\u003e\n\u003ctd\u003e25,317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"3201\" data-end=\"3368\"\u003e\u003cstrong data-start=\"3201\" data-end=\"3221\"\u003eWhat this means:\u003c\/strong\u003e\u003cbr data-start=\"3221\" data-end=\"3224\"\u003eAs ambient temperatures increase, total output slightly decreases. Proper ventilation of the condenser location is critical for peak efficiency.\u003c\/p\u003e\n\u003cp data-start=\"3370\" data-end=\"3509\"\u003eThe system is capable of maintaining a 55°F cellar temperature with condenser air intake temperatures up to 120°F when installed correctly.\u003c\/p\u003e\n\u003ch3 data-start=\"3516\" data-end=\"3558\"\u003e\u003cstrong\u003eFully Ducted Operation for Quiet Cellars\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3560\" data-end=\"3654\"\u003eThe Quantum Twin series is fully ducted, keeping mechanical noise and heat outside the cellar.\u003c\/p\u003e\n\u003cp data-start=\"3656\" data-end=\"3678\"\u003e\u003cstrong data-start=\"3656\" data-end=\"3678\"\u003eDuct Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3679\" data-end=\"3731\"\u003e\n\u003cli data-start=\"3679\" data-end=\"3691\"\u003e14” Supply\u003c\/li\u003e\n\u003cli data-start=\"3692\" data-end=\"3704\"\u003e14” Return\u003c\/li\u003e\n\u003cli data-start=\"3705\" data-end=\"3731\"\u003eUp to 35 ft per duct run\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3733\" data-end=\"3755\"\u003e\u003cstrong data-start=\"3733\" data-end=\"3755\"\u003eLine Set Distance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3756\" data-end=\"3813\"\u003e\n\u003cli data-start=\"3756\" data-end=\"3813\"\u003eCondenser may be installed up to 100 ft from evaporator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3815\" data-end=\"3832\"\u003e\u003cstrong data-start=\"3815\" data-end=\"3832\"\u003eNoise Levels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3833\" data-end=\"3873\"\u003e\n\u003cli data-start=\"3833\" data-end=\"3853\"\u003eEvaporator: 58 dBA\u003c\/li\u003e\n\u003cli data-start=\"3854\" data-end=\"3873\"\u003eCondenser: 58 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3875\" data-end=\"3980\"\u003eDucted systems are preferred in luxury builds where equipment visibility and vibration must be minimized.\u003c\/p\u003e\n\u003ch2 data-start=\"3987\" data-end=\"4032\"\u003e\u003cstrong\u003eElectrical Requirements (Planning Critical)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"4034\" data-end=\"4094\"\u003e\n\u003cstrong data-start=\"4034\" data-end=\"4049\"\u003eEvaporator: \u003c\/strong\u003e120V — 15-amp dedicated circuit required\u003c\/li\u003e\n\u003cli data-start=\"4096\" data-end=\"4155\"\u003e\n\u003cstrong data-start=\"4096\" data-end=\"4110\"\u003eCondenser: \u003c\/strong\u003e220V — 25-amp dedicated circuit required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4157\" data-end=\"4267\"\u003eElectrical planning must be completed prior to installation. Always verify breaker sizing and wiring capacity.\u003c\/p\u003e\n\u003ch3 data-start=\"4274\" data-end=\"4301\"\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4303\" data-end=\"4491\"\u003e\n\u003cli data-start=\"4303\" data-end=\"4322\"\u003eLiquid Line: 3\/8”\u003c\/li\u003e\n\u003cli data-start=\"4323\" data-end=\"4378\"\u003eSuction Line: 5\/8” (under 50 ft) or 3\/4” (over 50 ft)\u003c\/li\u003e\n\u003cli data-start=\"4379\" data-end=\"4423\"\u003eDrain Line: 3\/4” Female to base (CPVC\/PVC)\u003c\/li\u003e\n\u003cli data-start=\"4424\" data-end=\"4447\"\u003eLine set not included\u003c\/li\u003e\n\u003cli data-start=\"4448\" data-end=\"4491\"\u003eProfessional HVAC-R installation required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4493\" data-end=\"4558\"\u003eFailure to use a licensed technician will void warranty coverage.\u003c\/p\u003e\n\u003ch3 data-start=\"4493\" data-end=\"4558\"\u003e\u003cstrong\u003e24000 vs 18000 — When to Upgrade\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eMax Cu Ft\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantum 18000\u003c\/td\u003e\n\u003ctd\u003e5,000 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003eLarge residential cellars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantum 24000\u003c\/td\u003e\n\u003ctd\u003e7,500 cu. ft.\u003c\/td\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003eCommercial or estate-scale cellars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"4823\" data-end=\"4843\"\u003eChoose the 24000 if:\u003c\/p\u003e\n\u003cul data-start=\"4844\" data-end=\"4975\"\u003e\n\u003cli data-start=\"4844\" data-end=\"4879\"\u003eYour cellar exceeds 5,500 cu. ft.\u003c\/li\u003e\n\u003cli data-start=\"4880\" data-end=\"4912\"\u003eYou have higher glass exposure\u003c\/li\u003e\n\u003cli data-start=\"4913\" data-end=\"4939\"\u003eYou are in a hot climate\u003c\/li\u003e\n\u003cli data-start=\"4940\" data-end=\"4975\"\u003eYou want extra performance margin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4982\" data-end=\"5014\"\u003e\u003cstrong\u003eAdvanced Controls \u0026amp; Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5016\" data-end=\"5036\"\u003eThe system includes:\u003c\/p\u003e\n\u003cul data-start=\"5038\" data-end=\"5137\"\u003e\n\u003cli data-start=\"5038\" data-end=\"5079\"\u003eKDT digital touch display (50 ft cable)\u003c\/li\u003e\n\u003cli data-start=\"5080\" data-end=\"5137\"\u003eLiquid-temperature measuring bottle probe (50 ft cable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5139\" data-end=\"5251\"\u003eThe bottle probe measures actual wine temperature instead of ambient air, improving long-term aging consistency.\u003c\/p\u003e\n\u003ch2 data-start=\"5139\" data-end=\"5251\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQuantum Twin 24000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cellar Size\u003c\/td\u003e\n\u003ctd\u003e7,500 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor\u003c\/td\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (85°F)\u003c\/td\u003e\n\u003ctd\u003e21,519 \/ 25,317 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFM\u003c\/td\u003e\n\u003ctd\u003e590 (low), 650 (medium), 710 (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Dimensions\u003c\/td\u003e\n\u003ctd\u003e29.5”L x 30.9”W x 19.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser Dimensions\u003c\/td\u003e\n\u003ctd\u003e31.18”L x 10.75”W x 23.25”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Amps\u003c\/td\u003e\n\u003ctd\u003e9.2 (Running)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser Amps\u003c\/td\u003e\n\u003ctd\u003eLRA 46.6 \/ RLA 11.39 \/ FLA 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Limited Parts \u0026amp; Labor + 1-Year Grace Period\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eManuals for WhisperKOOL Quantum Twin 24000 Ducted Split:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Owner's Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Twin_Quantum_HE_OM_022124.pdf?v=1752176039\" target=\"_blank\"\u003eOwner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Quick Start Guide\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_QuickStart_Guide_Quantum_Twin_18000-24000.pdf?v=1752176031\" target=\"_blank\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Warranty Checklist\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Split-System-Warranty-Checklist_6_11_24_1.pdf?v=1752176421\" target=\"_blank\"\u003eWarranty Checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Quantum_ProductSheet_11_11.pdf?v=1752172066\" title=\"220V H.E Product Sheet\" rel=\"noopener\" target=\"_blank\"\u003e220V H.E Product Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Ducted_Split-Quantum_ProductSheet_020622.pdf?v=1752172065\" title=\"220V Copeland Product Sheet\" rel=\"noopener\" target=\"_blank\"\u003e220V Copeland Product Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Maintenance_Checklist_Quantum_H.E._220V.pdf?v=1752172393\" title=\"Maintenance Checklist\" rel=\"noopener\" target=\"_blank\"\u003eMaintenance Checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Charge Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Quantum_Twin_18000-24000_-_Charge_Chart.pdf?v=1752176660\" target=\"_blank\"\u003eCharge Chart\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"5808\" data-end=\"5830\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"5832\" data-end=\"6009\"\u003e\n\u003cstrong data-start=\"5832\" data-end=\"5865\"\u003e24V Thermostat Conversion Kit\u003cbr\u003e\u003c\/strong\u003eAllows integration with third-party smart thermostats (thermostat not included). Note: removes standard WhisperKOOL control and bottle probe.\u003c\/li\u003e\n\u003cli data-start=\"6011\" data-end=\"6092\"\u003e\n\u003cstrong data-start=\"6011\" data-end=\"6041\"\u003eExterior Condenser Housing\u003cbr\u003e\u003c\/strong\u003eRecommended for outdoor condenser installations.\u003c\/li\u003e\n\u003cli data-start=\"6094\" data-end=\"6183\"\u003e\n\u003cstrong data-start=\"6094\" data-end=\"6120\"\u003eCondenser Coil Coating\u003cbr\u003e\u003c\/strong\u003eProtects against salt-air corrosion in coastal environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"7335\" data-end=\"7364\"\u003e\u003cstrong\u003eProfessional Recommendation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"7366\" data-end=\"7505\"\u003eEvery wine cellar is unique. Glass percentage, insulation quality, ambient temperature, and vapor sealing significantly impact performance.\u003c\/p\u003e\n\u003cp data-start=\"7507\" data-end=\"7644\"\u003eBefore purchasing the Quantum Twin 24000, we strongly recommend performing a professional heat load calculation to confirm proper sizing.\u003c\/p\u003e\n\u003cp data-start=\"7646\" data-end=\"7778\"\u003eIf you need assistance determining whether this system is appropriate for your project, contact our cellar specialists for guidance.\u003c\/p\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52299583455519,"sku":"S-WKQS24000-220-FD","price":16369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/8094\/5695\/files\/whisperkool-quantum-twin-24000-ducted-split-system-220v-high-efficiency-1187288112.jpg?v=1775520258","url":"https:\/\/theimperialluxe.com\/products\/whisperkool-quantum-twin-24000-220v-high-efficiency-ducted-wine-cellar-cooling-systems","provider":"The Imperial Luxe","version":"1.0","type":"link"}